CoChat

A novel technique for nonvolitional assessment of quadriceps muscle endurance in humans

Open access
Swallow, E. B., Gosker, H. R., Ward, K. A., Moore, A. J., Dayer, M. J., Hopkinson, N. S., Schols, A. M. W. J., Moxham, J., Polkey, M. I. · 2007 · Journal of Applied Physiology
Cited by 121

The DOI matches its Crossref record; 4 of the 4 references it cites were found in a registry or an index.

Abstract

Assessment of quadriceps endurance is of interest to investigators studying human disease. We hypothesized that repetitive magnetic stimulation (rMS) of the intramuscular branches of the femoral nerve could be used to induce and quantify quadriceps endurance. To test this hypothesis, we used a novel stimulating coil to compare the quadriceps endurance properties in eight normal humans and, to confirm that the technique could be used in clinical practice, in eight patients with advanced chronic obstructive pulmonary disease (COPD). To validate the method, we compared in vivo contractile properties of the quadriceps muscle with the fiber-type composition and oxidative enzyme capacity. We used a Magstim Rapid 2 magnetic nerve stimulator with the coil wrapped around the quadriceps. Stimuli were given at 30 Hz, a duty cycle of 0.4 (2 s on, 3 s off), and for 50 trains. Force generation and the surface electromyogram were measured throughout. Quadriceps twitch force, elicited by supramaximal magnetic stimulation of the femoral nerve, was measured before and after the protocol. Quadriceps muscle biopsies were analyzed for oxidative (citrate synthase, CS) and glycolytic (phosphofructokinase, PFK) enzyme activity and myosin heavy chain isoform protein expression. The time for force to fall to 70% of baseline (T 70) was shorter in the COPD group than the control group: 55.6 ± 26.0 vs. 121 ± 38.7 s ( P = 0.0014). Considering patients and controls together, positive correlations were observed between T 70 and the proportion of type I fibers ( r = 0.68, P = 0.004) and CS-to-PFK ratio (CS/PFK) ( r = 0.67, P = 0.005). We conclude that quadriceps endurance assessed using rMS is feasible in clinical studies.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1152/japplphysiol.00025.2007

Cites

4 of 4 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 4 references

Cited by

Metadata

Authors
Swallow, E. B., Gosker, H. R., Ward, K. A., Moore, A. J., Dayer, M. J., Hopkinson, N. S., Schols, A. M. W. J., Moxham, J., & Polkey, M. I.
Venue
Journal of Applied Physiology
Published
2007-09
Volume
103
Issue
3
Pages
739-746
ISSN
  • 0161-7567 (ISSN-L)
  • 8750-7587
  • 1522-1601
OpenAlex
W2026946978
Cited by
121
References
4
FWCI
4.07
Type
journal article
Language
en
Open access
green

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.