Measuring airway exchange of endogenous acetone using a single-exhalation breathing maneuver
The DOI matches its Crossref record.
Abstract
Exhaled acetone is measured to estimate exposure or monitor diabetes and congestive heart failure. Interpreting this measurement depends critically on where acetone exchanges in the lung. Health professionals assume exhaled acetone originates from alveolar gas exchange, but experimental data and theoretical predictions suggest that acetone comes predominantly from airway gas exchange. We measured endogenous acetone in the exhaled breath to evaluate acetone exchange in the lung. The acetone concentration in the exhalate of healthy human subjects was measured dynamically with a quadrupole mass spectrometer and was plotted against exhaled volume. Each subject performed a series of breathing maneuvers in which the steady exhaled flow rate was the only variable. Acetone phase III had a positive slope (0.054 ± 0.016 liter−1) that was statistically independent of flow rate. Exhaled acetone concentration was normalized by acetone concentration in the alveolar air, as estimated by isothermal rebreathing. Acetone concentration in the rebreathed breath ranged from 0.8 to 2.0 parts per million. Normalized end-exhaled acetone concentration was dependent on flow and was 0.79 ± 0.04 and 0.85 ± 0.04 for the slow and fast exhalation rates, respectively. A mathematical model of airway and alveolar gas exchange was used to evaluate acetone transport in the lung. By doubling the connective tissue (epithelium + mucosal tissue) thickness, this model predicted accurately ( R 2 = 0.94 ± 0.05) the experimentally measured expirograms and demonstrated that most acetone exchange occurred in the airways of the lung. Therefore, assays using exhaled acetone measurements need to be reevaluated because they may underestimate blood levels.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Amann, A., Costello, B. D. L., Miekisch, W., Schubert, J., Buszewski, B., Pleil, J., Ratcliffe, N., & Risby, T. (2014) · Journal of Breath Research · doi:10.1088/1752-7155/8/3/034001 · Cited by 804
Assessment, origin, and implementation of breath volatile cancer markers
Haick, H., Broza, Y. Y., Mochalski, P., Ruzsanyi, V., & Amann, A. (2014) · Chem. Soc. Rev. · doi:10.1039/c3cs60329f · Cited by 644
Wang, C., & Sahay, P. (2009) · Sensors · doi:10.3390/s91008230 · Cited by 596
Breath analysis by nanostructured metal oxides as chemo-resistive gas sensors
Righettoni, M., Amann, A., & Pratsinis, S. E. (2015) · Materials Today · doi:10.1016/j.mattod.2014.08.017 · Cited by 487
Breath Analysis in Disease Diagnosis: Methodological Considerations and Applications
Lourenço, C., & Turner, C. (2014) · Metabolites · doi:10.3390/metabo4020465 · Cited by 314
Is breath acetone a biomarker of diabetes? A historical review on breath acetone measurements
Wang, Z., & Wang, C. (2013) · Journal of Breath Research · doi:10.1088/1752-7155/7/3/037109 · Cited by 309
Isoprene and acetone concentration profiles during exercise on an ergometer
King, J., Kupferthaler, A., Unterkofler, K., Koc, H., Teschl, S., Teschl, G., Miekisch, W., Schubert, J., Hinterhuber, H., & Amann, A. (2009) · Journal of Breath Research · doi:10.1088/1752-7155/3/2/027006 · Cited by 278
Quantitative breath analysis of volatile organic compounds of lung cancer patients
Song, G., Qin, T., Liu, H., Xu, G.-B., Pan, Y.-Y., Xiong, F.-X., Gu, K.-S., Sun, G.-P., & Chen, Z.-D. (2010) · Lung Cancer · doi:10.1016/j.lungcan.2009.03.029 · Cited by 260
Review of Non-Invasive Glucose Sensing Techniques: Optical, Electrical and Breath Acetone
Shokrekhodaei, M., & Quinones, S. (2020) · Sensors · doi:10.3390/s20051251 · Cited by 221
Measuring breath acetone for monitoring fat loss: Review
Anderson, J. C. (2015) · Obesity · doi:10.1002/oby.21242 · Cited by 211
“, mass spectrometers, gas chromatographs, UV or near-IR light detection, and metal oxide sensors) can measure partsper-million concentrations of acetone in breath under laboratory conditions (1,9,66,67).”
BackgroundMethodInfluentialSelf-citationTrends in Nanomaterial-Based Non-Invasive Diabetes Sensing Technologies
Makaram, P., Owens, D., & Aceros, J. (2014) · Diagnostics · doi:10.3390/diagnostics4020027 · Cited by 200
“non-alveolar during sample collection [108] Percentage of moisture in the breath Before/after smoking Presence of other disease conditions in patients (COPD, hypercapnia) Exercise, sports, etc.”
BackgroundKing, J., Mochalski, P., Kupferthaler, A., Unterkofler, K., Koc, H., Filipiak, W., Teschl, S., Hinterhuber, H., & Amann, A. (2010) · Physiological Measurement · doi:10.1088/0967-3334/31/9/008 · Cited by 189
“This is due to substantial interactions of such compounds with the water-like mucus layer lining the conducting airways, commonly referred to as the wash-in/wash-out effect (Anderson et al 2003, 2006).”
BackgroundElectronic nose: a non-invasive technology for breath analysis of diabetes and lung cancer patients
Behera, B., Joshi, R., Anil Vishnu, G. K., Bhalerao, S., & Pandya, H. J. (2019) · Journal of Breath Research · doi:10.1088/1752-7163/aafc77 · Cited by 179
Gas sensing and electrochemical properties of rare earthferrite, LnFeO 3 (Ln = Nd, Sm)
Anajafi, Z., Naseri, M., & Neri, G. (2020) · Ceramics International · doi:10.1016/j.ceramint.2020.07.139 · Cited by 34
Metadata
- Authors
- Anderson, J. C., Lamm, W. J. E., & Hlastala, M. P.
- Venue
- Journal of Applied Physiology
- Publisher
- American Physiological Society
- Published
- 2006-03
- Volume
- 100
- Issue
- 3
- Pages
- 880-889
- ISSN
- 0161-7567 (ISSN-L)
- 8750-7587
- 1522-1601
- OpenAlex
- W2112005649
- Cited by
- 116
- References
- 0
- FWCI
- 1.93
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.