The DOI matches its Crossref record; 6 of the 6 references it cites were found in a registry or an index.
Trends in Nanomaterial-Based Non-Invasive Diabetes Sensing Technologies
Open accessAbstract
Blood glucose monitoring is considered the gold standard for diabetes diagnostics and self-monitoring. However, the underlying process is invasive and highly uncomfortable for patients. Furthermore, the process must be completed several times a day to successfully manage the disease, which greatly contributes to the massive need for non-invasive monitoring options. Human serums, such as saliva, sweat, breath, urine and tears, contain traces of glucose and are easily accessible. Therefore, they allow minimal to non-invasive glucose monitoring, making them attractive alternatives to blood measurements. Numerous developments regarding noninvasive glucose detection techniques have taken place over the years, but recently, they have gained recognition as viable alternatives, due to the advent of nanotechnology-based sensors. Such sensors are optimal for testing the amount of glucose in serums other than blood thanks to their enhanced sensitivity and selectivity ranges, in addition to their size and compatibility with electronic circuitry. These nanotechnology approaches are rapidly evolving, and new techniques are constantly emerging. Hence, this manuscript aims to review current and future nanomaterial-based technologies utilizing saliva, sweat, breath and tears as a diagnostic medium for diabetes monitoring.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
T he D iagnostic A pplications of S aliva — A R eview
Kaufman, E., & Lamster, I. B. (2002) · Critical Reviews in Oral Biology & Medicine · doi:10.1177/154411130201300209 · Cited by 887
A Comprehensive Review of Glucose Biosensors Based on Nanostructured Metal-Oxides
Rahman, M. M., Ahammad, A. J. S., Jin, J.-H., Ahn, S. J., & Lee, J.-J. (2010) · Sensors · doi:10.3390/s100504855 · Cited by 762
Correlation Between Sweat Glucose and Blood Glucose in Subjects with Diabetes
Moyer, J., Wilson, D., Finkelshtein, I., Wong, B., & Potts, R. (2012) · Diabetes Technology & Therapeutics · doi:10.1089/dia.2011.0262 · Cited by 570
A contact lens with embedded sensor for monitoring tear glucose level
Yao, H., Shum, A. J., Cowan, M., Lähdesmäki, I., & Parviz, B. A. (2011) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2010.12.042 · Cited by 513
Measurement of tear glucose levels with amperometric glucose biosensor/capillary tube configuration
Yan, Q., Peng, B., Su, G., Cohan, B. E., Major, T. C., & Meyerhoff, M. E. (2011) · Analytical Chemistry · doi:10.1021/ac201700c · Cited by 185
Noninvasively measuring blood glucose using saliva
Yamaguchi, M., Mitsumori, M., & Kano, Y. (1998) · IEEE Engineering in Medicine and Biology Magazine · doi:10.1109/51.677170 · Cited by 129
Research works printed but not linked: 109
- Danaei, 2011, National, regional, and global trends in fasting plasma glucose and diabetes prevalence since 1980: Systematic analysis of health examination surveys and epidemiological studies with 370 country-years and 2·7 million participants, Lancet, 378, 31, 10.1016/S0140-6736(11)60679-X · DOI · Paper page
- Pickup, 2008, Nanomedicine and its potential in diabetes research and practice, Diabetes. Metab. Res. Rev., 24, 604, 10.1002/dmrr.893 · DOI
- Cash, 2010, Nanosensors and nanomaterials for monitoring glucose in diabetes, Trends Mol. Med., 16, 584, 10.1016/j.molmed.2010.08.002 · DOI · Paper page
- Newman, 2005, Home blood glucose biosensors: A commercial perspective, Biosens. Bioelectron., 20, 2435, 10.1016/j.bios.2004.11.012 · DOI · Paper page
- Nur, 2010, A fast and sensitive potentiometric glucose microsensor based on glucose oxidase coated ZnO nanowires grown on a thin silver wire, Sens. Actuators B Chem., 145, 869, 10.1016/j.snb.2009.12.072 · DOI · Paper page
- Kong, 2009, An amperometric glucose biosensor based on the immobilization of glucose oxidase on the ZnO nanotubes, Sens. Actuators B Chem., 138, 344, 10.1016/j.snb.2009.01.002 · DOI · Paper page
- Yang, 2009, ZnO Nanotube Arrays as Biosensors for Glucose, J. Phys. Chem. C, 113, 20169, 10.1021/jp901894j · DOI · Paper page
- Chi, 2009, Synthesis of ruthenium purple nanowire array for construction of sensitive and selective biosensors for glucose detection, Sens. Actuators B Chem., 140, 591, 10.1016/j.snb.2009.05.025 · doi:10.1016/j.snb.2009.05.025
- Liu, 2008, An Effective Amperometric Biosensor Based on Gold Nanoelectrode Arrays, Nanoscale Res. Lett., 4, 210, 10.1007/s11671-008-9227-0 · doi:10.1007/s11671-008-9227-0
- Santhosh, 2009, Fabrication of enzymatic glucose biosensor based on palladium nanoparticles dispersed onto poly(3,4-ethylenedioxythiophene) nanofibers, Bioelectrochemistry, 75, 61, 10.1016/j.bioelechem.2008.12.001 · doi:10.1016/j.bioelechem.2008.12.001
- Du, 2007, A simple method to fabricate a chitosan-gold nanoparticles film and its application in glucose biosensor, Bioelectrochemistry, 70, 342, 10.1016/j.bioelechem.2006.05.002 · DOI · Paper page
- Wang, 2009, Detection of glucose based on direct electron transfer reaction of glucose oxidase immobilized on highly ordered polyaniline nanotubes, Anal. Chem., 81, 1638, 10.1021/ac802421h · DOI · Paper page
- Hrapovic, 2004, Electrochemical biosensing platforms using platinum nanoparticles and carbon nanotubes, Anal. Chem., 76, 1083, 10.1021/ac035143t · DOI · Paper page
- Wang, 2003, Solubilization of carbon nanotubes by Nafion toward the preparation of amperometric biosensors, J. Am. Chem. Soc., 125, 2408, 10.1021/ja028951v · DOI · Paper page
- Wang, 2003, Enzyme-dispersed carbon-nanotube electrodes: A needle microsensor for monitoring glucose, Analyst, 128, 1382, 10.1039/b309928h · DOI
- Rubianes, 2003, Carbon nanotubes paste electrode, Electrochem. Commun., 5, 689, 10.1016/S1388-2481(03)00168-1 · DOI
- Lin, 2004, Glucose Biosensors Based on Carbon Nanotube Nanoelectrode Ensembles, Nano Lett., 4, 191, 10.1021/nl0347233 · DOI · Paper page
- Zhu, 2012, A critical review of glucose biosensors based on carbon nanomaterials: Carbon nanotubes and graphene, Sensors, 12, 5996, 10.3390/s120505996 · DOI · Paper page
- Okutucu, 2011, Molecularly imprinted polymers for separation of various sugars from human urine, Talanta, 87, 74, 10.1016/j.talanta.2011.09.043 · doi:10.1016/j.talanta.2011.09.043
- Siyang, S., Wongchoosuk, C., and Kerdcharoen, T. (2012, January 16–18). Diabetes diagnosis by direct measurement from urine odor using electronic nose. Proceedings of the 5th Biomedical Engineering International Conference, Ho Chi Minh, Vietnam. · DOI
- Su, 2012, Colorimetric detection of urine glucose based ZnFe2O4 magnetic nanoparticles, Anal. Chem., 84, 5753, 10.1021/ac300939z · DOI · Paper page
- Miyashita, 2009, Development of urine glucose meter based on micro-planer amperometric biosensor and its clinical application for self-monitoring of urine glucose, Biosens. Bioelectron., 24, 1336, 10.1016/j.bios.2008.07.072 · DOI
- Zhang, 2004, Carbon nanotube-chitosan system for electrochemical sensing based on dehydrogenase enzymes, Anal. Chem., 76, 5045, 10.1021/ac049519u · DOI
- Kang, 2007, A novel glucose biosensor based on immobilization of glucose oxidase in chitosan on a glassy carbon electrode modified with gold-platinum alloy nanoparticles/multiwall carbon nanotubes, Anal. Biochem., 369, 71, 10.1016/j.ab.2007.07.005 · DOI · Paper page
- Carlson, 2000, The salivary glands. Embryology, anatomy, and surgical applications, Surg. Clin. North Am., 80, 261, 10.1016/S0039-6109(05)70405-9 · doi:10.1016/s0039-6109(05)70405-9
- Malamud, 2011, Saliva as a diagnostic fluid, Dent. Clin. North Am., 55, 159, 10.1016/j.cden.2010.08.004 · DOI · Paper page
- Belazi, 2002, Salivary alterations in insulin-dependent diabetes mellitus, Int. J. Paediatr. Dent., 8, 29, 10.1046/j.1365-263X.1998.00057.x · doi:10.1046/j.1365-263x.1998.00057.x
- Vasconcelos, 2010, Comparative study of the concentration of salivary and blood glucose in type 2 diabetic patients, J. Oral Sci., 52, 293, 10.2334/josnusd.52.293 · DOI
- Cohen, 1988, Salivary composition in diabetic patients, J. Diabet. Complications, 2, 96, 10.1016/0891-6632(88)90011-6 · DOI
- Aydin, 2007, A comparison of ghrelin, glucose, alpha-amylase and protein levels in saliva from diabetics, J. Biochem. Mol. Biol., 40, 29
- Carda, 2006, Structural and functional salivary disorders in type 2 diabetic patients, Med. Oral Patol. Oral Cir. Bucal., 11, E309
- Heller, 1999, Implanted electrochemical glucose sensors for the management of diabetes, Annu. Rev. Biomed. Eng., 1, 153, 10.1146/annurev.bioeng.1.1.153 · DOI · Paper page
- Macaya, 2007, Simple glucose sensors with micromolar sensitivity based on organic electrochemical transistors, Sens. Actuators B Chem., 123, 374, 10.1016/j.snb.2006.08.038 · DOI · Paper page
- Shim, 2009, All-plastic electrochemical transistor for glucose sensing using a ferrocene mediator, Sensors, 9, 9896, 10.3390/s91209896 · DOI
- Cella, 2010, Single-Walled Carbon Nanotube-Based Chemiresistive Affinity Biosensors for Small Molecules: Ultrasensitive Glucose Detection, J. Am. Chem. Soc., 132, 5024, 10.1021/ja100503b · DOI · Paper page
- Tang, 2008, A new nanobiosensor for glucose with high sensitivity and selectivity in serum based on fluorescence resonance Energy transfer (FRET) between CdTe quantum dots and Au nanoparticles, Chemistry, 14, 3637, 10.1002/chem.200701871 · DOI · Paper page
- Barone, 2006, Reversible Control of Carbon Nanotube Aggregation for a Glucose Affinity Sensor, Angew. Chem., 118, 8318, 10.1002/ange.200603138 · DOI
- Lerner, 2013, Scalable, non-invasive glucose sensor based on boronic acid functionalized carbon nanotube transistors, Appl. Phys. Lett., 102, 183113, 10.1063/1.4804438 · DOI
- Das, 2011, A Glucose Sensor Based on an Aminophenyl Boronic Acid Bonded Conducting Polymer, Electroanalysis, 23, 2036, 10.1002/elan.201100145 · DOI
- 2010, A study on non-invasive detection of blood glucose concentration from human palm perspiration by using artificial neural networks, Expert Syst., 27, 156, 10.1111/j.1468-0394.2010.00523.x · DOI
- Olarte, O., Chilo, J., Pelegri-Sebastia, J., Barbe, K., and van Moer, W. (2013, January 3–7). Glucose detection in human sweat using an electronic nose. Proceedings of 35th Annual International Conference of the IEEE Engineering in Medicine and Biology Society, Osaka, Japan. · DOI
- So, 2012, Recent advances in noninvasive glucose monitoring, Med. Devices (Auckl)., 5, 45
- Klonoff, 1997, Noninvasive blood glucose monitoring, Diabetes Care, 20, 433, 10.2337/diacare.20.3.433 · DOI · Paper page
- Tamada, 1999, Noninvasive Glucose Monitoring, JAMA, 282, 1839, 10.1001/jama.282.19.1839 · DOI · Paper page
- Tura, 2010, Advances in the development of devices for noninvasive glycemia monitoring: Who will win the race?, Nutr. Ther. Metab., 28, 22
- 2012, State of the art and new perspectives in non-invasive glucose sensors, Rev. Mex. Ing. Biomed., 33, 41
- Diabetes Research in Children Network (DirecNet) Study Group (2004). Accuracy of the GlucoWatch G2 Biographer and the continuous glucose monitoring system during hypoglycemia: experience of the Diabetes Research in Children Network. Diabetes Care, 27, 722–726. · DOI
- Sun, 2010, Carbon nanotube composites for glucose biosensor incorporated with reverse iontophoresis function for noninvasive glucose monitoring, Int. J. Nanomed., 5, 343
- Leng, H., and Lin, Y. (2010). Design and fabrication of a sensor integrated MEMS/NANO-Skin system for human physiological response measurement. Proc. SPIE, 7647. · doi:10.1117/12.846934
- Miyoshi, Y., Tkeuchi, T., Saito, T., Saito, H., Kudo, H., Otsuka, K., and Mitsubayashi, K.A. (2007, January 16−19). Wearable humidity sensor with hydrophilic membrane by Soft-MEMS techniques. Proceedings of the 2nd IEEE International Conference on Nano/Micro Engineered and Molecular Systems, Bangkok, Thailand. · doi:10.1109/nems.2007.352264
- Hudspeth, M.A., and Kaya, T. (2012). Collagen as a Humidity Sensing Dielectric Material. MRS Proc., 1427. · doi:10.1557/opl.2012.1415
- Zhang, 2011, Noninvasive Diagnostic Devices for Diabetes through Measuring Tear Glucose, J. Diabetes Sci. Technol., 5, 166, 10.1177/193229681100500123 · DOI
- Peng, 2013, Evaluation of enzyme-based tear glucose electrochemical sensors over a wide range of blood glucose concentrations, Biosens. Bioelectron, 49, 204, 10.1016/j.bios.2013.05.014 · DOI · Paper page
- Jin, 1997, Determination of Glucose in Submicroliter Samples by CE-LIF Using Precolumn or On-Column Enzymatic Reactions, Anal. Chem., 69, 1326, 10.1021/ac960724m · DOI
- Badugu, 2005, Fluorescence sensors for monosaccharides based on the 6-methylquinolinium nucleus and boronic acid moiety: potential application to ophthalmic diagnostics, Talanta, 65, 762, 10.1016/j.talanta.2004.08.003 · DOI
- Baca, 2007, Mass spectral determination of fasting tear glucose concentrations in nondiabetic volunteers, Clin. Chem., 53, 1370, 10.1373/clinchem.2006.078543 · DOI · Paper page
- Yang, 2008, Towards the real-time monitoring of glucose in tear fluid: holographic glucose sensors with reduced interference from lactate and pH, Biosens. Bioelectron., 23, 899, 10.1016/j.bios.2007.09.016 · DOI · Paper page
- Kagie, 2008, Flexible Rolled Thick-Film Miniaturized Flow-Cell for Minimally Invasive Amperometric Sensing, Electroanalysis, 20, 1610, 10.1002/elan.200804253 · DOI
- Chu, 2009, A soft and flexible biosensor using a phospholipid polymer for continuous glucose monitoring, Biomed. Microdevices, 11, 837, 10.1007/s10544-009-9300-1 · DOI
- Mitsubayashi, 1995, A flexible biosensor for glucose, Electroanalysis, 7, 83, 10.1002/elan.1140070110 · DOI
- Yao, H., Afanasiev, A., Lahdesmaki, I., and Parviz, B.A. (2011, January 23−27). A dual microscale glucose sensor on a contact lens, tested in conditions mimicking the eye. Proceedings of the 24th IEEE International Conference on Micro Electro Mechanical Systems, Cancun, Mexico. · DOI
- Measuring glucose without needle pricks. Available online:http://www.fraunhofer.de/en/press/research-news/2012/september/measuring-glucose-without-needle-pricks.html.
- Falk, 2013, Miniature biofuel cell as a potential power source for glucose-sensing contact lenses, Anal. Chem., 85, 6342, 10.1021/ac4006793 · DOI · Paper page
- Haeringen, 1977, Collection method dependant concentrations of some metabolites in human tear fluid, with special reference to glucose in hyperglycaemic conditions, Albr. von Graefes Arch Exp. Ophthalmol., 202, 1, 10.1007/BF00496763 · DOI
- Abelson, 1981, Normal Human Tear pH by Direct Measurement, Arch. Ophthalmol., 99, 301, 10.1001/archopht.1981.03930010303017 · DOI · Paper page
- Claussen, 2012, Nanostructuring Platinum Nanoparticles on Multilayered Graphene Petal Nanosheets for Electrochemical Biosensing, Adv. Funct. Mater., 22, 3399, 10.1002/adfm.201200551 · DOI · Paper page
- Risby, 2006, Current status of clinical breath analysis, Appl. Phys. B, 85, 421, 10.1007/s00340-006-2280-4 · DOI · Paper page
- Miekisch, 2004, Diagnostic potential of breath analysis—Focus on volatile organic compounds, Clin. Chim. Acta., 347, 25, 10.1016/j.cccn.2004.04.023 · DOI · Paper page
- van de Kant, K.D., van der Sande, L.J., Jöbsis, Q., van Schayck, O.C., and Dompeling, E. (2012). Clinical use of exhaled volatile organic compounds in pulmonary diseases: a systematic review. Respir. Res., 13. · DOI · Paper page
- Peled, 2012, Non-invasive Breath Analysis of Pulmonary Nodules, J. Thorac. Oncol., 7, 1528, 10.1097/JTO.0b013e3182637d5f · DOI · Paper page
- Peng, 2010, Detection of lung, breast, colorectal, and prostate cancers from exhaled breath using a single array of nanosensors, Br. J. Cancer, 103, 542, 10.1038/sj.bjc.6605810 · DOI · Paper page
- Gisbert, 2004, Review article: 13C-urea breath test in the diagnosis of Helicobacter pylori infection—A critical review, Aliment. Pharmacol. Ther., 20, 1001, 10.1111/j.1365-2036.2004.02203.x · DOI · Paper page
- Logan, 1998, Urea breath tests in the management of Helicobacter pylori infection, Gut, 43, S47, 10.1136/gut.43.2008.S47 · DOI
- Rosias, 2004, Childhood asthma: exhaled markers of airway inflammation, asthma control score, and lung function tests, Pediatr. Pulmonol., 38, 107, 10.1002/ppul.20056 · DOI
- Fens, 2013, Exhaled breath analysis by electronic nose in airways disease. Established issues and key questions, Clin. Exp. Allergy, 43, 705, 10.1111/cea.12052 · DOI
- Koorevaar, 1976, Mammalian acetoacetate decarboxylase activity, Clin. Chim. Acta, 71, 173, 10.1016/0009-8981(76)90528-3 · doi:10.1016/0009-8981(76)90528-3
- Tassopoulos, 1969, Breath-acetone and blood-sugar measurements in diabetes, Lancet, 293, 1282, 10.1016/S0140-6736(69)92222-3 · DOI · Paper page
- Crofford, 1977, Acetone in breath and blood, Trans. Am. Clin. Clim. Assoc., 88, 128
- Haggard, 1944, The physiological principles governing the action of acetone together with determination of toxicity, J. Ind. Hyg. Toxicol, 26, 133
- Wang, 2008, An acetone breath analyzer using cavity ringdown spectroscopy: An initial test with human subjects under various situations, Meas. Sci. Technol., 19, 105604, 10.1088/0957-0233/19/10/105604 · DOI
- Wang, 2010, A Study on Breath Acetone in Diabetic Patients Using a Cavity Ringdown Breath Analyzer: Exploring Correlations of Breath Acetone With Blood Glucose and glycohemoglobin A1C, IEEE Sensors, 10, 54, 10.1109/JSEN.2009.2035730 · DOI · Paper page
- Turner, 2009, Breath acetone concentration decreases with blood glucose concentration in type I diabetes mellitus patients during hypoglycaemic clamps, J. Breath Res., 3, 046004, 10.1088/1752-7155/3/4/046004 · DOI · Paper page
- Stevens, S., Garner, C., Wei, C., Greenwood, R., Hamilton-Shield, J., Costello, B.d., Ratcliffe, N., and Probert, C.A. Study of volatile compounds in the breath of children with type 1 diabetes. Available online:http://arxiv.org/abs/1303.4210. · arXiv
- Chakraborty, 2008, Detection of biomarker in breath: A step towards noninvasive diabetes monitoring, Curr. Sci., 94, 237
- Yu, 2005, Analysis of diabetic patient’s breath with conducting polymer sensor array, Sens. Actuators B Chem., 108, 305, 10.1016/j.snb.2005.01.040 · DOI
- Kao, 2012, A sub-ppm acetone gas sensor for diabetes detection using 10 nm thick ultrathin InN FETs, Sensors, 12, 7157, 10.3390/s120607157 · DOI · Paper page
- Wang, L., and Gouma, P. (2013). Metal Oxide Nanomaterials for Chemical Sensors, Springer.
- Wang, 2010, Nanosensor device for breath acetone detection, Sens. Lett., 8, 709, 10.1166/sl.2010.1334 · DOI
- Wang, 2009, An Acetone Nanosensor For Non-invasive Diabetes Detection, AIP Conf. Proc., 1137, 206, 10.1063/1.3156509 · DOI
- Wang, 1997, A novel method for diabetes diagnosis based on electronic nose, Biosens. Bioelectron., 12, 1031
- Righettoni, 2010, Thermally Stable, Silica-Doped ε-WO 3 for Sensing of Acetone in the Human Breath, Chem. Mater., 22, 3152, 10.1021/cm1001576 · doi:10.1021/cm1001576
- Ding, 2013, Photoinduced Charge Transfer and Acetone Sensitivity of Single-Walled Carbon Nanotube–Titanium Dioxide Hybrids, J. Am. Chem. Soc., 135, 9015, 10.1021/ja402887v · DOI
- Lu, 2006, A carbon nanotube sensor array for sensitive gas discrimination using principal component analysis, J. Electroanal. Chem., 593, 105, 10.1016/j.jelechem.2006.03.056 · DOI
- Khodadadi, 2012, Highly sensitive and selective sensors to volatile organic compounds using MWCNTs/SnO2, Sens. Actuators B Chem., 166–167, 150
- Wang, 2013, Is breath acetone a biomarker of diabetes? A historical review on breath acetone measurements, J. Breath Res., 7, 037109, 10.1088/1752-7155/7/3/037109 · DOI · Paper page
- Likhodii, 2002, Breath acetone is a reliable indicator of ketosis in adults consuming ketogenic meals, Am. J. Clin. Nutr., 76, 65, 10.1093/ajcn/76.1.65 · DOI · Paper page
- Anderson, 2006, Measuring airway exchange of endogenous acetone using a single-exhalation breathing maneuver, J. Appl. Physiol., 100, 880, 10.1152/japplphysiol.00868.2005 · DOI
- Dillon, 2009, Novel noninvasive breath test method for screening individuals at risk for diabetes, Diabetes Care, 32, 430, 10.2337/dc08-1578 · DOI
- Greiter, 2010, Differences in Exhaled Gas Profiles Between Patients with Type 2 Diabetes and Healthy Controls, Diabetes Technol. Ther., 12, 455, 10.1089/dia.2009.0181 · DOI
- Mohammadi, 2014, In vivo evaluation of a chip based near infrared sensor for continuous glucose monitoring, Biosens. Bioelectron., 53, 99, 10.1016/j.bios.2013.09.043 · DOI · Paper page
- Radhakumary, 2011, Naked eye detection of glucose in urine using glucose oxidase immobilized gold nanoparticles, Anal. Chem., 83, 2829, 10.1021/ac1032879 · doi:10.1021/ac1032879
- Lee, S.J., Lee, Y.J., and Park, J.Y. (2013, January 3–6). A micro-fabricated non-enzymatic urine glucose sensor using nafion coated nanoporous Pt composite electrodes. Proceedings of 2013 IEEE Sensors, Baltimore, MD, USA. · doi:10.1109/icsens.2013.6688313
- Xiao, 2009, Nonenzymatic glucose sensor based on ultrasonic-electrodeposition of bimetallic PtM (M=Ru, Pd and Au) nanoparticles on carbon nanotubes-ionic liquid composite film, Biosens. Bioelectron., 24, 3481, 10.1016/j.bios.2009.04.045 · DOI · Paper page
- Chen, 2010, Nonenzymatic amperometric sensing of glucose by using palladium nanoparticles supported on functional carbon nanotubes, Biosens. Bioelectron., 25, 1803, 10.1016/j.bios.2009.12.035 · DOI
- Zhiguo, 2011, An ultrasensitive electrochemical biosensor for glucose using CdTe-CdS core–shell quantum dot as ultrafast electron transfer relay between graphene-gold nanocomposite and gold nanoparticle, Electrochim. Acta, 56, 9162, 10.1016/j.electacta.2011.07.117 · DOI
- Liao, 2013, Highly selective and sensitive glucose sensors based on organic electrochemical transistors with graphene-modified gate electrodes, J. Mater. Chem. B, 1, 3820, 10.1039/c3tb20451k · DOI · Paper page
- Yoon, 2013, Fabrication of a microneedle/CNT hierarchical micro/nano surface electrochemical sensor and its in-vitro glucose sensing characterization, Sensors, 13, 16672, 10.3390/s131216672 · DOI
- Hu, 2013, Construction of near-infrared photonic crystal glucose-sensing materials for ratiometric sensing of glucose in tears, Biosens. Bioelectron., 48, 94, 10.1016/j.bios.2013.03.082 · DOI
- Manju, 2011, Detection of glucose in synthetic tear fluid using dually functionalized gold nanoparticles, Talanta, 85, 2643, 10.1016/j.talanta.2011.08.033 · DOI
Cited by
Enzyme‐Based Glucose Sensor: From Invasive to Wearable Device
Lee, H., Hong, Y. J., Baik, S., Hyeon, T., & Kim, D. (2018) · Advanced Healthcare Materials · doi:10.1002/adhm.201701150 · Cited by 778
Accessing analytes in biofluids for peripheral biochemical monitoring
Heikenfeld, J., Jajack, A., Feldman, B., Granger, S. W., Gaitonde, S., Begtrup, G., & Katchman, B. A. (2019) · Nature Biotechnology · doi:10.1038/s41587-019-0040-3 · Cited by 758
Pullano, S. A., Greco, M., Bianco, M. G., Foti, D., Brunetti, A., & Fiorillo, A. S. (2022) · Theranostics · doi:10.7150/thno.64035 · Cited by 210
A paper strip based non-invasive glucose biosensor for salivary analysis
Soni, A., & Jha, S. K. (2015) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2014.09.042 · Cited by 173
Lekha, S., & M, S. (2021) · IEEE Reviews in Biomedical Engineering · doi:10.1109/rbme.2020.2993591 · Cited by 105
Metadata
- Authors
- Makaram, P., Owens, D., & Aceros, J.
- Venue
- Diagnostics
- Publisher
- MDPI AG
- Published
- 2014-04-21
- Volume
- 4
- Issue
- 2
- Pages
- 27-46
- ISSN
- 2075-4418 (ISSN-L)
- OpenAlex
- W1976647954
- Cited by
- 200
- References
- 6
- FWCI
- 4.78
- Type
- journal article
- Language
- en
- Open access
- gold
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Trends in Nanomaterial-Based Non-Invasive Diabetes Sensing Technologies. https://app.cochat.ai/papers/10.3390/diagnostics4020027
- The paper
- Makaram, P., Owens, D., & Aceros, J. (2014). Trends in Nanomaterial-Based Non-Invasive Diabetes Sensing Technologies. Diagnostics. https://doi.org/10.3390/diagnostics4020027
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.