The DOI matches its Crossref record; 16 of the 16 references it cites were found in a registry or an index.
Mechanical ventilation results in progressive contractile dysfunction in the diaphragm
Open accessAbstract
These experiments tested the hypothesis that a relatively short duration of controlled mechanical ventilation (MV) will impair diaphragmatic maximal specific force generation (specific P o) and that this force deficit will be exacerbated with increased time on the ventilator. To test this postulate, adult Sprague-Dawley rats were randomly divided into one of six experimental groups: 1) control ( n = 12); 2) 12 h of MV ( n = 4); 3) 18 h of MV ( n = 4); 4) 18 h of anesthesia and spontaneous breathing ( n = 4); 5) 24 h of MV ( n = 7); and 6) 24 h of anesthesia and spontaneous breathing ( n = 4). MV animals were anesthetized, tracheostomized, and ventilated with room air. Animals in the control group were acutely anesthetized but were not exposed to MV. Animals in two spontaneous breathing groups were anesthetized and breathed spontaneously for either 18 or 24 h. No differences ( P > 0.05) existed in diaphragmatic specific P o between control and the two spontaneous breathing groups. In contrast, compared with control, all durations of MV resulted in a reduction ( P < 0.05) in diaphragmatic specific tension at stimulation frequencies ranging from 15 to 160 Hz. Furthermore, the MV-induced decrease in diaphragmatic specific P o was time dependent, with specific P o being ∼18 and ∼46% lower ( P < 0.05) in animals mechanically ventilated for 12 and 24 h, respectively. These data support the hypothesis that relatively short-term MV impairs diaphragmatic contractile function and that the magnitude of MV-induced force deficit increases with time on the ventilator.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
A physiological role for titin and nebulin in skeletal muscle
Horowits, R., Kempner, E. S., Bisher, M. E., & Podolsky, R. J. (1986) · Nature · doi:10.1038/323160a0 · Cited by 448
Effects of mechanical ventilation on diaphragmatic contractile properties in rats.
Le Bourdelles, G., Viires, N., Boczkowski, J., Seta, N., Pavlovic, D., & Aubier, M. (1994) · American Journal of Respiratory and Critical Care Medicine · doi:10.1164/ajrccm.149.6.8004310 · Cited by 275
Anzueto, A., Peters, J. I., Tobin, M. J., De Los Santos, R., Seidenfeld, J. J., Moore, G., Cox, W. J., & Coalson, J. J. (1997) · Critical Care Medicine · doi:10.1097/00003246-199707000-00021 · Cited by 196
Human respiratory muscles: fibre morphology and capillary supply
Mizuno, M. (1991) · European Respiratory Journal · doi:10.1183/09031936.93.04050587 · Cited by 148
Effects of Steroids on Diaphragmatic Function in Rats
Viires, N., Pavlovic, D., Parienté, R., & Aubier, M. (1990) · American Review of Respiratory Disease · doi:10.1164/ajrccm/142.1.34 · Cited by 118
Kelly, S., Rosa, A., Field, S. L., Coughlin, M., Shizgal, H., & Macklem, P. T. (1984) · American Review of Respiratory Disease · doi:10.1164/arrd.1984.130.1.33 · Cited by 118
Effects of Sepsis on Diaphragmatic Function in Rats
Boczkowski, J., Dureuil, B., Branger, C., Pavlović, D., Murciano, D., Parienté, R., & Aubier, M. (1988) · American Review of Respiratory Disease · doi:10.1164/ajrccm/138.2.260 · Cited by 106
Reactive Oxygen and Nitric Oxide in Skeletal Muscle
Reid, M. B. (1996) · Physiology · doi:10.1152/physiologyonline.1996.11.3.114 · Cited by 91
Effects of clenbuterol on contractile and biochemical properties of skeletal muscle
DODD, S. L., Powers, S. K., Vrabas, I. S., Criswell, D. S., Stetson, S., & HUSSAIN, R. (1996) · Medicine & Science in Sports & Exercise · doi:10.1097/00005768-199606000-00005 · Cited by 88
Self-citationArchitecture, composition, and contractile properties of rat soleus muscle grafts
Segal, S. S., White, T. P., & Faulkner, J. A. (1986) · American Journal of Physiology-Cell Physiology · doi:10.1152/ajpcell.1986.250.3.c474 · Cited by 83
Cited by
ICU-Acquired Weakness and Recovery from Critical Illness
Kress, J. P., & Hall, J. B. (2014) · New England Journal of Medicine · doi:10.1056/nejmra1209390 · Cited by 855
Mechanical Ventilation–induced Diaphragm Atrophy Strongly Impacts Clinical Outcomes
Goligher, E. C., Dres, M., Fan, E., Rubenfeld, G. D., Scales, D. C., Herridge, M. S., Vorona, S., Sklar, M. C., Rittayamai, N., Lanys, A., et al. (2018) · American Journal of Respiratory and Critical Care Medicine · doi:10.1164/rccm.201703-0536oc · Cited by 813
Rapidly Progressive Diaphragmatic Weakness and Injury during Mechanical Ventilation in Humans
Jaber, S., Petrof, B. J., Jung, B., Chanques, G., Berthet, J.-P., Rabuel, C., Bouyabrine, H., Courouble, P., Koechlin-Ramonatxo, C., Sebbane, M., et al. (2011) · American Journal of Respiratory and Critical Care Medicine · doi:10.1164/rccm.201004-0670oc · Cited by 709
Disorders of the Respiratory Muscles
Laghi, F., & Tobin, M. J. (2003) · American Journal of Respiratory and Critical Care Medicine · doi:10.1164/rccm.2206020 · Cited by 687
Evolution of Diaphragm Thickness during Mechanical Ventilation. Impact of Inspiratory Effort
Goligher, E. C., Fan, E., Herridge, M. S., Murray, A., Vorona, S., Brace, D., Rittayamai, N., Lanys, A., Tomlinson, G., Singh, J. M., et al. (2015) · American Journal of Respiratory and Critical Care Medicine · doi:10.1164/rccm.201503-0620oc · Cited by 608
Respiratory weakness is associated with limb weakness and delayed weaning in critical illness*
De Jonghe, B., Bastuji-Garin, S., Durand, M.-C., Malissin, I., Rodrigues, P., Cerf, C., Outin, H., & Sharshar, T. (2007) · Critical Care Medicine · doi:10.1097/01.ccm.0000281450.01881.d8 · Cited by 554
Ventilator-induced Diaphragmatic Dysfunction
Vassilakopoulos, T., & Petrof, B. J. (2004) · American Journal of Respiratory and Critical Care Medicine · doi:10.1164/rccm.200304-489cp · Cited by 520
Oxidative stress and disuse muscle atrophy
Powers, S. K., Kavazis, A. N., & McClung, J. M. (2007) · Journal of Applied Physiology · doi:10.1152/japplphysiol.01202.2006 · Cited by 472
Self-citationGoligher, E. C., Laghi, F., Detsky, M. E., Farias, P., Murray, A., Brace, D., Brochard, L. J., Sebastien-Bolz, S., Rubenfeld, G. D., Kavanagh, B. P., et al. (2015) · Intensive Care Medicine · doi:10.1007/s00134-015-3687-3 · Cited by 448
Critical illness-associated diaphragm weakness
Dres, M., Goligher, E. C., Heunks, L. M. A., & Brochard, L. J. (2017) · Intensive Care Medicine · doi:10.1007/s00134-017-4928-4 · Cited by 402
Mechanisms of disuse muscle atrophy: role of oxidative stress
Powers, S. K., Kavazis, A. N., & DeRuisseau, K. C. (2005) · American Journal of Physiology-Regulatory, Integrative and Comparative Physiology · doi:10.1152/ajpregu.00469.2004 · Cited by 368
“During controlled MV, all breaths are delivered by the ventilator and the diaphragm is completely inactive (45).”
Self-citationShanely, R. A., Zergeroglu, M. A., Lennon, S. L., Sugiura, T., Yimlamai, T., Enns, D., Belcastro, A., & Powers, S. K. (2002) · American Journal of Respiratory and Critical Care Medicine · doi:10.1164/rccm.200202-088oc · Cited by 348
Self-citationAssist–Control Mechanical Ventilation Attenuates Ventilator-induced Diaphragmatic Dysfunction
Sassoon, C. S. H., Zhu, E., & Caiozzo, V. J. (2004) · American Journal of Respiratory and Critical Care Medicine · doi:10.1164/rccm.200401-042oc · Cited by 324
Goligher, E. C., Laghi, F., Detsky, M. E., Farias, P., Murray, A., Brace, D., Brochard, L. J., Bolz, S.-S., Rubenfeld, G. D., Kavanagh, B. P., et al. (2015) · Intensive Care Medicine · doi:10.1007/s00134-015-3724-2 · Cited by 315
Intensive care unit-acquired weakness: Risk factors and prevention
de Jonghe, B., Lacherade, J.-C., Sharshar, T., & Outin, H. (2009) · Critical Care Medicine · doi:10.1097/ccm.0b013e3181b6e64c · Cited by 305
Callahan, L. A., & Supinski, G. S. (2009) · Critical Care Medicine · doi:10.1097/ccm.0b013e3181b6e439 · Cited by 298
Intensive care unit-acquired weakness
Griffiths, R. D., & Hall, J. B. (2010) · Critical Care Medicine · doi:10.1097/ccm.0b013e3181cc4b53 · Cited by 276
Hermans, G., Agten, A., Testelmans, D., Decramer, M., & Gayan-Ramirez, G. (2010) · Critical Care · doi:10.1186/cc9094 · Cited by 274
Mechanical Ventilation–induced Diaphragm Disuse in Humans Triggers Autophagy
Hussain, S. N. A., Mofarrahi, M., Sigala, I., Kim, H. C., Vassilakopoulos, T., Maltais, F., Bellenis, I., Chaturvedi, R., Gottfried, S. B., Metrakos, P., et al. (2010) · American Journal of Respiratory and Critical Care Medicine · doi:10.1164/rccm.201002-0234oc · Cited by 264
Powers, S. K., Hudson, M. B., Nelson, W. B., Talbert, E. E., Min, K., Szeto, H. H., Kavazis, A. N., & Smuder, A. J. (2011) · Critical Care Medicine · doi:10.1097/ccm.0b013e3182190b62 · Cited by 255
Aydin, N. B., Teke, T., Toy, H., & Uzun, K. (2014) · Advances in Clinical and Experimental Medicine · doi:10.17219/acem/37019 · Cited by 4
Metadata
- Authors
- Powers, S. K., Shanely, R. A., Coombes, J. S., Koesterer, T. J., McKenzie, M., Van Gammeren, D., Cicale, M., & Dodd, S. L.
- Venue
- Journal of Applied Physiology
- Publisher
- American Physiological Society
- Published
- 2002-05-01
- Volume
- 92
- Issue
- 5
- Pages
- 1851-1858
- ISSN
- 0161-7567 (ISSN-L)
- 8750-7587
- 1522-1601
- OpenAlex
- W2127483068
- Cited by
- 319
- References
- 16
- FWCI
- 8.87
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.