CoChat

A comparison between the technical absorbent and ventilated capsule methods for measuring local sweat rate

Open access
Morris, Nathan B., Cramer, Matthew N., Hodder, Simon G., Havenith, George, Jay, Ollie · 2013 · Journal of Applied Physiology
Cited by 91

The DOI matches its Crossref record; 5 of the 5 references it cites were found in a registry or an index.

Abstract

This study assessed the accuracy of the technical absorbent (TA) method for measuring local sweat rate (LSR) relative to the well-established ventilated capsule (VC) method during steady-state and nonsteady-state sweating using large and small sample surface areas on the forearm and midback. Forty participants (38 males and two females) cycled at 60% peak oxygen consumption for 75 min in either a temperate [22.3 ± 0.9°C, 32 ± 17% relative humidity (RH)] or warm (32.5 ± 0.8°C, 29 ± 7% RH) environment. Simultaneous bilateral comparisons of 5-min LSR measurements using the TA and VC methods were performed for the back and forearm after 10, 30, 50, and 70 min. LSR values, measured using the TA method, were highly correlated with the VC method at all time points, irrespective of sample surface area and body region (all P < 0.001). On average, ∼79% of the variability observed in LSR measured with the VC method was described by the TA method. The mean difference in absolute LSR using the TA method (TA-VC with 95% confidence intervals) was −0.23 [−0.30,−0.16], −0.11 [−0.21,0.00], −0.03 [−0.14,+0.08], and +0.02 [−0.07,+0.11] mg·cm−2·min−1 after 10, 30, 50, and 70 min of exercise, respectively. Duplicate LSR measurements within each method during steady-state sweating were highly correlated (TA: r = 0.96, P < 0.001, n = 20; VC: r = 0.97, P < 0.001, n = 20) with a mean bias of +0.07 ± 0.14 and +0.01 ± 0.10 mg·cm−2·min−1 for TA and VC methods, respectively. The mean smallest detectable difference in LSR was 0.12 and 0.05 mg·min−1·cm−2 for TA and VC methods, respectively. These data support the TA method as a reliable alternative for measuring the rate of sweat appearance on the skin surface.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1152/japplphysiol.01088.2012

Cites

5 of 5 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 5 references

Cited by

Metadata

Authors
Morris, N. B., Cramer, M. N., Hodder, S. G., Havenith, G., & Jay, O.
Venue
Journal of Applied Physiology
Published
2013-03-15
Volume
114
Issue
6
Pages
816-823
ISSN
  • 0161-7567 (ISSN-L)
  • 8750-7587
  • 1522-1601
OpenAlex
W1992640540
Cited by
91
References
5
FWCI
1.84
Type
journal article
Language
en
Open access
green

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.