The DOI matches its Crossref record; 34 of the 34 references it cites were found in a registry or an index.
Removal of Movement Artifact From High-Density EEG Recorded During Walking and Running
Open accessAbstract
Although human cognition often occurs during dynamic motor actions, most studies of human brain dynamics examine subjects in static seated or prone conditions. EEG signals have historically been considered to be too noise prone to allow recording of brain dynamics during human locomotion. Here we applied a channel-based artifact template regression procedure and a subsequent spatial filtering approach to remove gait-related movement artifact from EEG signals recorded during walking and running. We first used stride time warping to remove gait artifact from high-density EEG recorded during a visual oddball discrimination task performed while walking and running. Next, we applied infomax independent component analysis (ICA) to parse the channel-based noise reduced EEG signals into maximally independent components (ICs) and then performed component-based template regression. Applying channel-based or channel-based plus component-based artifact rejection significantly reduced EEG spectral power in the 1.5- to 8.5-Hz frequency range during walking and running. In walking conditions, gait-related artifact was insubstantial: event-related potentials (ERPs), which were nearly identical to visual oddball discrimination events while standing, were visible before and after applying noise reduction. In the running condition, gait-related artifact severely compromised the EEG signals: stable average ERP time-courses of IC processes were only detectable after artifact removal. These findings show that high-density EEG can be used to study brain dynamics during whole body movements and that mechanical artifact from rhythmic gait events may be minimized using a template regression procedure.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Delorme, A., & Makeig, S. (2004) · Journal of Neuroscience Methods · doi:10.1016/j.jneumeth.2003.10.009 · Cited by 24,371
Self-citationAn Information-Maximization Approach to Blind Separation and Blind Deconvolution
Bell, A. J., & Sejnowski, T. J. (1995) · Neural Computation · doi:10.1162/neco.1995.7.6.1129 · Cited by 8,986
Removing electroencephalographic artifacts by blind source separation
Jung, T., Makeig, S., Humphries, C., Lee, T.-W., McKeown, M. J., Iragui, V. J., & Sejnowski, T. J. (2000) · Psychophysiology · doi:10.1017/s0048577200980259 · Cited by 3,334
Self-citationIndependent Component Analysis of Electroencephalographic Data
Makeig, S., Bell, A. J., Jung, T., & B, T. J. S. A. (1995) · neural information processing systems · Cited by 2,476
Self-citationThe role of executive function and attention in gait
Yogev‐Seligmann, G., Hausdorff, J. M., & Giladi, N. (2008) · Movement Disorders · doi:10.1002/mds.21720 · Cited by 2,165
Lee, T.-W., Girolami, M., & Sejnowski, T. J. (1999) · Neural Computation · doi:10.1162/089976699300016719 · Cited by 1,967
Delorme, A., Sejnowski, T., & Makeig, S. (2007) · NeuroImage · doi:10.1016/j.neuroimage.2006.11.004 · Cited by 1,759 · cited 1×
“Epochs with a probability of occurrence 3 SD from the mean across all epochs were rejected from further analysis (Delorme et al. 2007).”
BackgroundSelf-citationJung, T.-P., Makeig, S., Westerfield, M., Townsend, J., Courchesne, E., & Sejnowski, T. J. (2000) · Clinical Neurophysiology · doi:10.1016/s1388-2457(00)00386-2 · Cited by 1,322
Self-citationA Method for Removing Imaging Artifact from Continuous EEG Recorded during Functional MRI
Allen, P. J., Josephs, O., & Turner, R. (2000) · NeuroImage · doi:10.1006/nimg.2000.0599 · Cited by 1,301 · cited 2×
“Artifact template subtraction procedures have been used successfully to remove fMRI gradient artifact from EEG signals (Allen et al. 2000).”
MethodLearning Overcomplete Representations
Lewicki, M. S., & Sejnowski, T. J. (2000) · Neural Computation · doi:10.1162/089976600300015826 · Cited by 1,129
Cited by
EEG artifact removal—state-of-the-art and guidelines
Urigüen, J. A., & Garcia-Zapirain, B. (2015) · Journal of Neural Engineering · doi:10.1088/1741-2560/12/3/031001 · Cited by 963
Brain-Machine Interfaces: From Basic Science to Neuroprostheses and Neurorehabilitation
Lebedev, M. A., & Nicolelis, M. A. L. (2017) · Physiological Reviews · doi:10.1152/physrev.00027.2016 · Cited by 653
Electrocortical activity is coupled to gait cycle phase during treadmill walking
Gwin, J. T., Gramann, K., Makeig, S., & Ferris, D. P. (2011) · NeuroImage · doi:10.1016/j.neuroimage.2010.08.066 · Cited by 479
Self-citationMethods for artifact detection and removal from scalp EEG: A review
Islam, M. K., Rastegarnia, A., & Yang, Z. (2016) · Neurophysiologie Clinique/Clinical Neurophysiology · doi:10.1016/j.neucli.2016.07.002 · Cited by 457
Plöchl, M., Ossandón, J. P., & König, P. (2012) · Frontiers in Human Neuroscience · doi:10.3389/fnhum.2012.00278 · Cited by 372
Robust artifactual independent component classification for BCI practitioners
Winkler, I., Brandl, S., Horn, F., Waldburger, E., Allefeld, C., & Tangermann, M. (2014) · Journal of Neural Engineering · doi:10.1088/1741-2560/11/3/035013 · Cited by 327
Neuroergonomics: a review of applications to physical and cognitive work
Mehta, R. K., & Parasuraman, R. (2013) · Frontiers in Human Neuroscience · doi:10.3389/fnhum.2013.00889 · Cited by 306
Cognition in action: imaging brain/body dynamics in mobile humans
Gramann, K., Gwin, J. T., Ferris, D. P., Oie, K., Jung, T.-P., Lin, C.-T., Liao, L.-D., & Makeig, S. (2011) · Reviews in the Neurosciences · doi:10.1515/rns.2011.047 · Cited by 302
Self-citationTrends in EEG-BCI for daily-life: Requirements for artifact removal
Minguillon, J., Lopez-Gordo, M. A., & Pelayo, F. (2017) · Biomedical Signal Processing and Control · doi:10.1016/j.bspc.2016.09.005 · Cited by 289
Kwak, N.-S., Müller, K.-R., & Lee, S.-W. (2017) · PLOS ONE · doi:10.1371/journal.pone.0172578 · Cited by 272
EEG power spectral measures of cognitive workload: A meta‐analysis
Chikhi, S., Matton, N., & Blanchet, S. (2022) · Psychophysiology · doi:10.1111/psyp.14009 · Cited by 258
FORCe: Fully online and automated artifact removal for brain-computer interfacing
Daly, I., Scherer, R., Billinger, M., & Muller-Putz, G. (2015) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2014.2346621 · Cited by 174
Chuang, C.-H., Chang, K.-Y., Huang, C.-S., & Jung, T.-P. (2022) · NeuroImage · doi:10.1016/j.neuroimage.2022.119586 · Cited by 88
Shi, Y., Zhu, Y., Mehta, R. K., & Du, J. (2020) · Advanced Engineering Informatics · doi:10.1016/j.aei.2020.101153 · Cited by 81
Shan, H., Liu, Y., & Stefanov, T. (2018) · Proceedings of the Twenty-Seventh International Joint Conference on Artificial Intelligence · doi:10.24963/ijcai.2018/222 · Cited by 53
Asynchronous Prediction of Human Gait Intention in a Pseudo Online Paradigm Using Wavelet Transform
Hasan, S. M. S., Siddiquee, M. R., & Bai, O. (2020) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2020.2998778 · Cited by 22
Getting LOST : A conceptual framework for supporting and enhancing spatial navigation in aging
Weisberg, S. M., Ebner, N. C., & Seidler, R. D. (2024) · WIREs Cognitive Science · doi:10.1002/wcs.1669 · Cited by 12
Metadata
- Authors
- Gwin, J. T., Gramann, K., Makeig, S., & Ferris, D. P.
- Venue
- Journal of Neurophysiology
- Publisher
- American Physiological Society
- Published
- 2010-06
- Volume
- 103
- Issue
- 6
- Pages
- 3526-3534
- ISSN
- 0022-3077 (ISSN-L)
- 1522-1598
- OpenAlex
- W2121528650
- Cited by
- 481
- References
- 34
- FWCI
- 11.95
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.