Long-Term, Multisite, Parallel, In-Cell Recording and Stimulation by an Array of Extracellular Microelectrodes
The DOI matches its Crossref record; 6 of the 6 references it cites were found in a registry or an index.
Abstract
Here we report on the development of a novel neuroelectronic interface consisting of an array of noninvasive gold-mushroom-shaped microelectrodes (gMμEs) that practically provide intracellular recordings and stimulation of many individual neurons, while the electrodes maintain an extracellular position. The development of this interface allows simultaneous, multisite, long-term recordings of action potentials and subthreshold potentials with matching quality and signal-to-noise ratio of conventional intracellular sharp glass microelectrodes or patch electrodes. We refer to the novel approach as “in-cell recording and stimulation by extracellular electrodes” to differentiate it from the classical intracellular recording and stimulation methods. This novel technique is expected to revolutionize the analysis of neuronal networks in relations to learning, information storage and can be used to develop novel drugs as well as high fidelity neural prosthetics and brain-machine systems.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Neuronal ensemble control of prosthetic devices by a human with tetraplegia
Hochberg, L. R., Serruya, M. D., Friehs, G. M., Mukand, J. A., Saleh, M., Caplan, A. H., Branner, A., Chen, D., Penn, R. D., & Donoghue, J. P. (2006) · Nature · doi:10.1038/nature04970 · Cited by 3,295 · cited 1×
“…arrays enables investigators to record and stimulate large populations of excitable cells for days and months without inflicting mechanical dam- ages to the cell plasma membrane (Berdondini et al. 2009; Hochberg et al. 2006; Hutzler et al. 2006; Rubehn et al. 2009; Shahaf et al. 2008).”
BackgroundElectrical stimulation of excitable tissue: design of efficacious and safe protocols
Merrill, D. R., Bikson, M., & Jefferys, J. G. R. (2005) · Journal of Neuroscience Methods · doi:10.1016/j.jneumeth.2004.10.020 · Cited by 2,078 · cited 1×
“…limited charge transfer to the plasma membrane, by the risk of damaging the cells by electroporation (He et al. 2007; Rubinsky 2007; Ryttsen et al. 2000), or by irreversible electrochemical reaction products (Brummer et al. 1983; Harnack et al. 2004; Merrill et al. 2005; Yao et al. 2001).”
BackgroundStuart, L. M., & Ezekowitz, R. A. B. (2005) · Immunity · doi:10.1016/j.immuni.2005.05.002 · Cited by 667 · cited 2×
“To “replace” the classical approach of pushing microelectrodes into the cell, we used a peptide that induces, at the cell- E point of contact, phagocytotic activity (a conserved cell biological mechanism for the internalization of particles) (Stuart and Ezekowitz 2005).”
BackgroundMethodA MEMS-based flexible multichannel ECoG-electrode array
Rubehn, B., Bosman, C., Oostenveld, R., Fries, P., & Stieglitz, T. (2009) · Journal of Neural Engineering · doi:10.1088/1741-2560/6/3/036003 · Cited by 387
Polytrodes: High-Density Silicon Electrode Arrays for Large-Scale Multiunit Recording
Blanche, T. J., Spacek, M. A., Hetke, J. F., & Swindale, N. V. (2005) · Journal of Neurophysiology · doi:10.1152/jn.01023.2004 · Cited by 282 · cited 1×
“Interestingly, recent studies also revealed occasional positive extracellular 1 mV high action potentials when extracellular electrodes were introduced into cat visual cortex under in vivo conditions (Blanche et al. 2005; Gold et al. 2009).”
BackgroundBrummer, S. B., Robblee, L. S., & Hambrecht, F. T. (1983) · Annals of the New York Academy of Sciences · doi:10.1111/j.1749-6632.1983.tb31628.x · Cited by 205
Cited by
Multi-electrode array technologies for neuroscience and cardiology
Spira, M. E., & Hai, A. (2013) · Nature Nanotechnology · doi:10.1038/nnano.2012.265 · Cited by 991
“Measurements of the neurons input resistance before and after stimulation by gMμEs showed no change, affirming that high enough charge transfer can be applied to evoke APs without damage to the cell 64 .”
BackgroundMethodInfluentialSelf-citationZhang, A., & Lieber, C. M. (2016) · Chemical Reviews · doi:10.1021/acs.chemrev.5b00608 · Cited by 621
Intracellular recording of action potentials by nanopillar electroporation
Xie, C., Lin, Z., Hanson, L., Cui, Y., & Cui, B. (2012) · Nature Nanotechnology · doi:10.1038/nnano.2012.8 · Cited by 593
Biosensor technology: recent advances in threat agent detection and medicine
Kirsch, J., Siltanen, C., Zhou, Q., Revzin, A., & Simonian, A. (2013) · Chemical Society Reviews · doi:10.1039/c3cs60141b · Cited by 462
A nanoelectrode array for obtaining intracellular recordings from thousands of connected neurons
Abbott, J., Ye, T., Krenek, K., Gertner, R. S., Ban, S., Kim, Y., Qin, L., Wu, W., Park, H., & Ham, D. (2019) · Nature Biomedical Engineering · doi:10.1038/s41551-019-0455-7 · Cited by 272
Qing, Q., Jiang, Z., Xu, L., Gao, R., Mai, L., & Lieber, C. M. (2014) · Nature Nanotechnology · doi:10.1038/nnano.2013.273 · Cited by 257
High‐Aspect‐Ratio Nanostructured Surfaces as Biological Metamaterials
Higgins, S. G., Becce, M., Belessiotis‐Richards, A., Seong, H., Sero, J. E., & Stevens, M. M. (2020) · Advanced Materials · doi:10.1002/adma.201903862 · Cited by 256
Dynamics of cortical dendritic membrane potential and spikes in freely behaving rats.
Moore, J. J., Ravassard, P. M., Ho, D., Acharya, L., Kees, A. L., Vuong, C., & Mehta, M. R. (2017) · Science · doi:10.1126/science.aaj1497 · Cited by 110
Linking hippocampal multiplexed tuning, Hebbian plasticity and navigation
Moore, J. J., Cushman, J. D., Acharya, L., Popeney, B., & Mehta, M. R. (2021) · Nature · doi:10.1038/s41586-021-03989-z · Cited by 69
Perspectives on electrical neural recording: a revisit to the fundamental concepts
Guo, L. (2020) · Journal of Neural Engineering · doi:10.1088/1741-2552/ab702f · Cited by 28
Metadata
- Authors
- Hai, A., Shappir, J., & Spira, M. E.
- Venue
- Journal of Neurophysiology
- Publisher
- American Physiological Society
- Published
- 2010-07
- Volume
- 104
- Issue
- 1
- Pages
- 559-568
- ISSN
- 0022-3077 (ISSN-L)
- 1522-1598
- OpenAlex
- W2048529438
- Cited by
- 123
- References
- 6
- FWCI
- 2.11
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.