CoChat

Anisotropic and heterogeneous diffusion in the turtle cerebellum: implications for volume transmission

Rice, M. E., Okada, Y. C., Nicholson, C. · 1993 · Journal of Neurophysiology
Cited by 105

The DOI matches its Crossref record.

Abstract

1. Measurements of extracellular diffusion properties were made in three orthogonal axes of the molecular and granular layers of the isolated turtle cerebellum with the use of iontophoresis of tetramethylammonium (TMA+) combined with ion-selective microelectrodes. 2. Diffusion in the extracellular space of the molecular layer was anisotropic, that is, there was a different value for the tortuosity factor, lambda i, associated with each axis of that layer. The x- and y-axes lay in the plane parallel to the pial surface of this lissencephalic cerebellum with the x-axis in the direction of the parallel fibers. The z-axis was perpendicular this plane. The tortuosity values were lambda x = 1.44 +/- 0.01, lambda y = 1.95 +/- 0.02, and lambda z = 1.58 +/- 0.01 (mean +/- SE). By contrast, the granular layer was isotropic with a single tortuosity value, lambda Gr = 1.77 +/- 0.01. 3. These data confirm the applicability of appropriately extended Fickian equations to describe diffusion in anisotropic porous media, including brain tissue. 4. Heterogeneity between the molecular and granular layer was revealed by a striking difference in extracellular volume fraction, alpha, for each layer. In the molecular layer alpha = 0.31 +/- 0.01, whereas in the granular layer alpha = 0.22 +/- 0.01. 5. Volume fraction and tortuosity affected the time course and amplitude of extracellular TMA+ concentration after iontophoresis. This was modeled by the use of the average parameters determined experimentally, and the nonspherical pattern of diffusion in the molecular layer was compared with the spherical distribution in the granular layer and agarose gel by computing isoconcentration ellipsoids. 6. One functional consequence of these results was demonstrated by measuring local changes in [K+]o and [Ca2+]o after microiontophoresis of a cerebellar transmitter, glutamate. The ratios of ion shifts in the x- and y-axes in the granular layer were close to unity, with a ratio of 1.04 +/- 0.08 for the rise in [K+]o and 1.03 +/- 0.17 for the decrease in [Ca2+]o. In contrast, ion shifts in the molecular layer had an x:y ratio of 1.44 +/- 0.14 for the rise in [K+]o and 2.10 +/- 0.42 for the decrease in [Ca2+]o. 7. These data demonstrate that the structure of cellular aggregates can channel the migration of substances in the extracellular microenvironment, and this could be a mechanism for volume transmission of chemical signals. For example, the preferred diffusion direction of glutamate along the parallel fibers would help constrain an incoming excitatory stimulus to stay "on-beam."

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1152/jn.1993.70.5.2035

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

Metadata

Authors
Rice, M. E., Okada, Y. C., & Nicholson, C.
Venue
Journal of Neurophysiology
Published
1993-11-01
Volume
70
Issue
5
Pages
2035-2044
ISSN
  • 0022-3077 (ISSN-L)
  • 1522-1598
OpenAlex
W2410114835
Cited by
105
References
0
FWCI
0.92
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.