Gait Recognition Using Wearable Motion Recording Sensors
Open accessThe DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.
Abstract
This paper presents an alternative approach, where gait is collected by the sensors attached to the person's body. Such wearable sensors record motion (e.g. acceleration) of the body parts during walking. The recorded motion signals are then investigated for person recognition purposes. We analyzed acceleration signals from the foot, hip, pocket and arm. Applying various methods, the best EER obtained for foot-, pocket-, arm- and hip- based user authentication were 5%, 7%, 10% and 13%, respectively. Furthermore, we present the results of our analysis on security assessment of gait. Studying gait-based user authentication (in case of hip motion) under three attack scenarios, we revealed that a minimal effort mimicking does not help to improve the acceptance chances of impostors. However, impostors who know their closest person in the database or the genders of the users can be a threat to gait-based authentication. We also provide some new insights toward the uniqueness of gait in case of foot motion. In particular, we revealed the following: a sideway motion of the foot provides the most discrimination, compared to an up-down or forward-backward directions; and different segments of the gait cycle provide different level of discrimination.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
The humanID gait challenge problem: data sets, performance, and analysis
Sarkar, S., Phillips, P. J., Liu, Z., Vega, I. R., Grother, P., & Bowyer, K. W. (2005) · IEEE Transactions on Pattern Analysis and Machine Intelligence · doi:10.1109/tpami.2005.39 · Cited by 1,133
Yu, S., Tan, D., & Tan, T. (2006) · 18th International Conference on Pattern Recognition (ICPR'06) · doi:10.1109/icpr.2006.67 · Cited by 1,056 · cited 3×
“Motion Recording Sensor.”
Influential
Cited by
Smartphone and Smartwatch-Based Biometrics Using Activities of Daily Living
Weiss, G. M., Yoneda, K., & Hayajneh, T. (2019) · IEEE Access · doi:10.1109/access.2019.2940729 · Cited by 360
Inertial Sensor-Based Gait Recognition: A Review
Sprager, S., & Juric, M. (2015) · Sensors · doi:10.3390/s150922089 · Cited by 347
Deep Learning-Based Gait Recognition Using Smartphones in the Wild
Zou, Q., Wang, Y., Wang, Q., Zhao, Y., & Li, Q. (2020) · IEEE Transactions on Information Forensics and Security · doi:10.1109/tifs.2020.2985628 · Cited by 305
Deep Learning-Based Gait Recognition Using Smartphones in the Wild
Zou, Q., Wang, Y., Wang, Q., Zhao, Y., & Li, Q. (2018) · arXiv · doi:10.48550/arxiv.1811.00338 · Cited by 305
Cell phone-based biometric identification
Kwapisz, J. R., Weiss, G. M., & Moore, S. A. (2010) · 2010 Fourth IEEE International Conference on Biometrics: Theory, Applications and Systems (BTAS) · doi:10.1109/btas.2010.5634532 · Cited by 281
Ngo, T. T., Makihara, Y., Nagahara, H., Mukaigawa, Y., & Yagi, Y. (2014) · Pattern Recognition · doi:10.1016/j.patcog.2013.06.028 · Cited by 281
User Verification Leveraging Gait Recognition for Smartphone Enabled Mobile Healthcare Systems
Ren, Y., Chen, Y., Chuah, M. C., & Yang, J. (2015) · IEEE Transactions on Mobile Computing · doi:10.1109/tmc.2014.2365185 · Cited by 123
Security, Privacy, and Usability in Continuous Authentication: A Survey
Baig, A. F., & Eskeland, S. (2021) · Sensors · doi:10.3390/s21175967 · Cited by 98
A Comprehensive Review on Secure Biometric-Based Continuous Authentication and User Profiling
Ayeswarya, S., & Singh, K. J. (2024) · IEEE Access · doi:10.1109/access.2024.3411783 · Cited by 66
Weakly Supervised Multi-Task Representation Learning for Human Activity Analysis Using Wearables
Sheng, T., & Huber, M. (2020) · Proceedings of the ACM on Interactive, Mobile, Wearable and Ubiquitous Technologies · doi:10.1145/3397330 · Cited by 28
Metadata
- Authors
- Gafurov, D., & Snekkenes, E.
- Venue
- EURASIP Journal on Advances in Signal Processing
- Published
- 2009-06-07
- Volume
- 2009
- Issue
- 1
- ISSN
- 1110-8657 (ISSN-L)
- 1687-6180
- OpenAlex
- W2042769429
- Cited by
- 120
- References
- 2
- FWCI
- 5.05
- Type
- journal article
- Language
- en
- Open access
- gold
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.