Obstacles in Haemocompatibility Testing
Open accessThe DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.
Abstract
ISO 10993-4 is an international standard describing the methods of testing of medical devices for interactions with blood for regulatory purpose. The complexity of blood responses to biomaterial surfaces and the variability of blood functions in different individuals and species pose difficulties in standardisation. Moreover,in vivo or in vitro testing, as well as the clinical relevance of certain findings, is still matter of debate. This review deals with the major remaining problems, including a brief explanation of surface interactions with blood, the current ISO 10993 requirements for testing, and the role of in vitro test models. The literature is reviewed on anticoagulation, shear rate, blood-air interfaces, incubation time, and the importance of evaluation of the surface area after blood contact. Two test categories deserve further attention: complement and platelet function, including the effects on platelets from adhesion proteins, venipuncture, and animal derived- blood. The material properties, hydrophilicity, and roughness, as well as reference materials, are discussed. Finally this review calls for completing the acceptance criteria in the ISO standard based on a panel of test results.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Surface Chemistry Influences Implant Biocompatibility
Tang, L., Thevenot, P., & Hu, W. (2008) · Current Topics in Medicinal Chemistry · doi:10.2174/156802608783790901 · Cited by 800 · cited 1×
“They adhere to surfaces via different receptors (glycoproteins (GP)) depending on the nature of thematerial, the structure, and charge of the surface and the prevailing rheological conditions [121–123].”
Frost, M. C., Reynolds, M. M., & Meyerhoff, M. E. (2005) · Biomaterials · doi:10.1016/j.biomaterials.2004.06.006 · Cited by 343
Zhang, H., Annich, G. M., Miskulin, J., Osterholzer, K., Merz, S. I., Bartlett, R. H., & Meyerhoff, M. E. (2002) · Biomaterials · doi:10.1016/s0142-9612(01)00274-5 · Cited by 168
Cited by
Blood-Contacting Biomaterials: In Vitro Evaluation of the Hemocompatibility
Weber, M., Steinle, H., Golombek, S., Hann, L., Schlensak, C., Wendel, H. P., & Avci-Adali, M. (2018) · Frontiers in Bioengineering and Biotechnology · doi:10.3389/fbioe.2018.00099 · Cited by 728
Ren, X., Feng, Y., Guo, J., Wang, H., Li, Q., Yang, J., Hao, X., Lv, J., Ma, N., & Li, W. (2015) · Chemical Society Reviews · doi:10.1039/c4cs00483c · Cited by 573
Bernard, M., Jubeli, E., Pungente, M. D., & Yagoubi, N. (2018) · Biomaterials Science · doi:10.1039/c8bm00518d · Cited by 350
Pacharra, S., Ortiz, R., McMahon, S., Wang, W., Viebahn, R., Salber, J., & Quintana, I. (2019) · Journal of Biomedical Materials Research Part B: Applied Biomaterials · doi:10.1002/jbm.b.34155 · Cited by 38
Pacharra, S., McMahon, S., Duffy, P., Basnett, P., Yu, W., Seisel, S., Stervbo, U., Babel, N., Roy, I., Viebahn, R., et al. (2020) · Frontiers in Bioengineering and Biotechnology · doi:10.3389/fbioe.2020.00991 · Cited by 25
Metadata
- Authors
- van Oeveren, W.
- Venue
- Scientifica
- Publisher
- Wiley
- Published
- 2013
- Volume
- 2013
- Pages
- 1-14
- ISSN
- 2090-908X (ISSN-L)
- OpenAlex
- W1969720022
- Cited by
- 100
- References
- 3
- FWCI
- 3.02
- Type
- journal article
- Language
- en
- Open access
- gold
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Obstacles in Haemocompatibility Testing. https://app.cochat.ai/papers/10.1155/2013/392584
- The paper
- van Oeveren, W. (2013). Obstacles in Haemocompatibility Testing. Scientifica. https://doi.org/10.1155/2013/392584
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.