Static Eccentricity Fault Recognition in Three‐Phase Line Start Permanent Magnet Synchronous Motor Using Finite Element Method
Open accessThe DOI matches its Crossref record; 43 of the 43 references it cites were found in a registry or an index.
Abstract
This paper is dedicated to investigating static eccentricity in a three‐phase LSPMSM. The modeling of LSPMSM with static eccentricity between stator and rotor is developed using finite element method (FEM). The analytical expression for the permeance and flux components of nonuniform air‐gap due to static eccentricity fault is discussed. Various indexes for static eccentricity detection using stator current signal of IM and permanent magnet synchronous motor (PMSM) are presented. Since LSPMSM is composed of a rotor which is a combination of these two motors, the ability of these features is evaluated for static eccentricity diagnosis in LSPMSM. The simulated stator current signal of LSPMSM in the presence of static eccentricity is analyzed in frequency domain using power spectral density (PSD). It is demonstrated that static eccentricity fault generates a series of low frequency harmonic components in the form of sidebands around the fundamental frequency. Moreover, the amplitudes of these components increase in proportion to the fault severity. According to the mentioned observations, an accurate frequency pattern is specified for static eccentricity detection in three‐phase LSPMSM.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Figures


![Figure 3 The computation style of air-gap field [35].](https://figures.cochat.ai/paper-figures/54cf8583b58a4221bd297dda784877d2/static-eccentricity-fault-recognition-in-threephase-line-start-permanent-magnet-figure-3.png)

![Figure 5 The location of stator and rotor under static eccentricity condition [24].](https://figures.cochat.ai/paper-figures/94bd261dd5ec4f33a5ec6dbd06baeaca/static-eccentricity-fault-recognition-in-threephase-line-start-permanent-magnet-figure-5.png)




















Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
The cited source says what the claim attributes to it.
In the citing paper
“The basic diagnostic signals in eccentricity diagnosis are: stator current [135], [143]- [146], [150], [151], [156]- [159], [161], [162], mechanical vibrations [149], [155], [156], noise [155], an airgap search coil voltage [149], [152], [156], [160], stator voltage [159], speed [159], load torque [159], d-axis stator inductance Ld [147], [148], BEMF [160] and unbalanced magnetic pull [153], [154]”
From Fault Diagnosis and Fault-Tolerant Control of PMSM Drives–State of the Art and Future Challenges (2022) · cites this paper as [150]
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Condition Monitoring and Fault Diagnosis of Electrical Motors—A Review
Nandi, S., Toliyat, H. A., & Li, X. (2005) · IEEE Transactions on Energy Conversion · doi:10.1109/tec.2005.847955 · Cited by 2,382 · cited 1×
“Each fault generates particular harmonic components in the stator current spectra in which extracting these features is referring to the specific fault in the motor [18, 19].”
BackgroundCause and analysis of stator and rotor failures in three-phase squirrel-cage induction motors
Bonnett, A. H., & Soukup, G. C. (1992) · IEEE Transactions on Industry Applications · doi:10.1109/28.148460 · Cited by 593
Vibration and current monitoring for detecting airgap eccentricity in large induction motors
Cameron, J. R., Thomson, W. T., & Dow, A. B. (1986) · IEE Proceedings B Electric Power Applications · doi:10.1049/ip-b.1986.0022 · Cited by 512
Cause and analysis of stator and rotor failures in 3-phase squirrel cage induction motors
Bonnett, A. K., & Soukup, G. C. (2002) · Conference Record of 1991 Annual Pulp and Paper Industry Technical Conference · doi:10.1109/papcon.1991.239667 · Cited by 489 · cited 2×
“Therefore, theUMP compels the rotor to move toward the area of the narrowest airgap length until the abrasion of the stator core subsequently generates abnormal vibration and severe damage to the rotor, the windings, and the stator [27].”
BackgroundStatic-, Dynamic-, and Mixed-Eccentricity Fault Diagnoses in Permanent-Magnet Synchronous Motors
Ebrahimi, B. M., Faiz, J., & Roshtkhari, M. J. (2009) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2009.2029577 · Cited by 386 · cited 5×
“Several indexes have been proposed for eccentricity fault detection in different types of electrical motors such as [7, 20–22] in IM and [23, 24] in PMSM.”
BackgroundInfluentialInduction machine drive condition monitoring and diagnostic research—a survey
Singh, G. K., & Ahmed Saleh Al Kazzaz, S. (2003) · Electric Power Systems Research · doi:10.1016/s0378-7796(02)00172-4 · Cited by 362
Nandi, S., Ahmed, S., & Toliyat, H. A. (2001) · IEEE Transactions on Energy Conversion · doi:10.1109/60.937205 · Cited by 340
Nandi, S., Ahmed, S., & Toliyat, H. (2001) · IEEE Power Engineering Review · doi:10.1109/mper.2001.4311622 · Cited by 298 · cited 2×
“Afterwards, these components bring subsequent pole pair rotor MMF harmonics [22, 36] with the content of R ± p n , which interact withP 0 and yield the following types of air-gap flux components regarding stator (Φ gs 2 ) and rotor (Φ gr 2 ):”
BackgroundMethodDetecting Rotor Faults in Low Power Permanent Magnet Synchronous Machines
le Roux, W., Harley, R. G., & Habetler, T. G. (2007) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2006.886620 · Cited by 274
Ebrahimi, B. M., Javan Roshtkhari, M., Faiz, J., & Khatami, S. V. (2014) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2013.2263777 · Cited by 271 · cited 2×
“Thematerials characteristic and stator winding formation highly influence the fault detection criteria [16, 40].”
BackgroundHong, J., Park, S., Hyun, D., Kang, T.-J., Lee, S. B., Kral, C., & Haumer, A. (2012) · IEEE Transactions on Industry Applications · doi:10.1109/tia.2012.2191253 · Cited by 219 · cited 1×
“stator at the setup or subsequent to maintenance, incorrect bearing positioning, bearing deterioration, shaft deflection, housings imperfection, end-shield misalignment, excessive tolerance, rotor weight, or pressure of interlocking ribbon [30–32].”
BackgroundThomson, W. T., & Barbour, A. (1998) · IEEE Transactions on Energy Conversion · doi:10.1109/60.736320 · Cited by 173 · cited 3×
“In case a motor operates under faulty condition, some unexpected phenomenon comes up, which ismore accurate to apply finite element method rather than other approaches such as WFM [10, 14].”
MethodLine start permanent magnet synchronous motors: Challenges and opportunities
Hassanpour Isfahani, A., & Vaez-Zadeh, S. (2009) · Energy · doi:10.1016/j.energy.2009.04.022 · Cited by 169 · cited 4×
“Besides, the permanent magnets generate an opposing torque at the starting status which diminishes by designing the high-deepness rotor slots [3, 6].”
BackgroundInfluentialThomson, W. T., Rankin, D., & Dorrell, D. G. (1999) · IEEE Transactions on Energy Conversion · doi:10.1109/60.815075 · Cited by 163
Detection of Eccentricity Faults in Induction Machines Based on Nameplate Parameters
Nandi, S., Ilamparithi, T. C., Lee, S. B., & Hyun, D. (2011) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2010.2055772 · Cited by 154
Fei, W., Luk, P. C. K., Ma, J., Shen, J., & Yang, G. (2009) · IEEE Transactions on Magnetics · doi:10.1109/tmag.2009.2022179 · Cited by 153
Kang, G.-H., Hur, J., Nam, H., Hong, J.-P., & Kim, G.-T. (2003) · IEEE Transactions on Magnetics · doi:10.1109/tmag.2003.810330 · Cited by 139 · cited 1×
“The cage equipped permanent magnet motor known as LSPMSM has been introduced as the high efficiency motor with high starting capability with no need of drive system [3, 4].”
BackgroundSeera, M., Lim, C. P., Nahavandi, S., & Loo, C. K. (2014) · Expert Systems with Applications · doi:10.1016/j.eswa.2014.02.028 · Cited by 136
Comprehensive Eccentricity Fault Diagnosis in Induction Motors Using Finite Element Method
Faiz, J., Ebrahimi, B. M., Akin, B., & Toliyat, H. A. (2009) · IEEE Transactions on Magnetics · doi:10.1109/tmag.2009.2012812 · Cited by 132
Detection of stator winding faults in induction motors using three-phase current monitoring
Sharifi, R., & Ebrahimi, M. (2010) · ISA Transactions · doi:10.1016/j.isatra.2010.10.008 · Cited by 118 · cited 1×
“Therefore, the rotor slot harmonic (RSH) also called principle slot harmonics (PSH) can be derived as [37]”
BackgroundFaiz, J., & Ojaghi, M. (2008) · Mechatronics · doi:10.1016/j.mechatronics.2008.07.004 · Cited by 108
The design of high-efficiency line-start motors
McClay, C. I., & Knight, A. M. (2000) · IEEE Transactions on Industry Applications · doi:10.1109/28.887206 · Cited by 94
Sahraoui, M., Ghoggal, A., Zouzou, S. E., & Benbouzid, M. (2008) · Simulation Modelling Practice and Theory · doi:10.1016/j.simpat.2008.08.007 · Cited by 91 · cited 1×
“The winding function method (WFM) is introduced for modeling and simulation of electrical motors in order to evaluate their dynamic performance at healthy condition and under internal faults such as eccentricity between stator and rotor [10–13].”
MethodA Study on the Optimal Rotor Design of LSPM Considering the Starting Torque and Efficiency
Kim, W., Kim, K., Kim, S.-J., Kang, D., Go, S.-C., Lee, H.-W., Chun, Y., & Lee, J. H. (2009) · IEEE Transactions on Magnetics · doi:10.1109/tmag.2009.2012757 · Cited by 84 · cited 8×
“Accordingly, the idea of replacing IMs with higher efficiency electrical motors is seriously being considered.”
MethodInfluentialThe design of high-efficiency line-start motors
Knight, A. M., & McClay, C. I. (2003) · IEEE Industry Applications Society Annual Meeting (IAS) · doi:10.1109/ias.1999.800002 · Cited by 76 · cited 1×
“As it is reported, the electrical motors use up to 50%–60% of electric energy in different applications [2, 3] and induction motors (IMs) are expending 96% from this part of energy only in United States [3].”
BackgroundFaiz, J., Ebrahimi, B. M., & Sharifian, M. B. B. (2006) · Electromagnetics · doi:10.1080/02726340600873003 · Cited by 75
Magnets faults characterization for Permanent Magnet Synchronous Motors
Casadei, D., Filippetti, F., Rossi, C., & Stefani, A. (2009) · 2009 IEEE International Symposium on Diagnostics for Electric Machines, Power Electronics and Drives · doi:10.1109/demped.2009.5292770 · Cited by 74
Ebrahimi, B. M., Faiz, J., & Araabi, B. N. (2010) · IET Electric Power Applications · doi:10.1049/iet-epa.2009.0149 · Cited by 65 · cited 2×
“The permeance of an air-gap contains stator slotting permeance and smooth rotor in PMSM which can be written as [26]”
BackgroundField Harmonics in Induction Motors
Liwschitz, M. M. (1942) · Electrical Engineering · doi:10.1109/t-aiee.1942.5058444 · Cited by 61
Detection of airgap eccentricity using line current spectrum of induction motors
Güldemir, H. (2002) · Electric Power Systems Research · doi:10.1016/s0378-7796(02)00154-2 · Cited by 58 · cited 2×
“Figure 3: The computation style of air-gap field [35].”
BackgroundSamaga, B. L. R., & Vittal, K. P. (2011) · International Journal of Electrical Power & Energy Systems · doi:10.1016/j.ijepes.2011.10.011 · Cited by 57 · cited 1×
“The winding function method (WFM) is introduced for modeling and simulation of electrical motors in order to evaluate their dynamic performance at healthy condition and under internal faults such as eccentricity between stator and rotor [10–13].”
MethodAkar, M. (2012) · Mechanical Systems and Signal Processing · doi:10.1016/j.ymssp.2012.04.003 · Cited by 57
Yahia, K., Cardoso, A. J. M., Ghoggal, A., & Zouzou, S. E. (2014) · ISA Transactions · doi:10.1016/j.isatra.2013.12.002 · Cited by 52 · cited 2×
“Accordingly, the magnetic forces are balanced in the opposite directions, but when the eccentricity emerges, this air-gap lessens on one side whereas it increases on the other side at any gyration angle which causes higher absorption force through the shorter gap [9, 27].”
BackgroundTorkaman, H., & Afjei, E. S. (2012) · IEEE Transactions on Magnetics · doi:10.1109/tmag.2012.2213606 · Cited by 51
Kim, T., Hwang, S.-M., Kim, K., Jung, W.-B., & Kim, C.-U. (2001) · IEEE Transactions on Magnetics · doi:10.1109/20.951316 · Cited by 48 · cited 1×
“It must be noted that the type of electrical motors has significant influence on fault detection based on their different structures [25, 26].”
BackgroundDiagnosis of Static Eccentricity in Switched Reluctance Motors Based on Mutually Induced Voltages
Faiz, J., & Pakdelian, S. (2008) · IEEE Transactions on Magnetics · doi:10.1109/tmag.2008.921097 · Cited by 44 · cited 1×
“Nevertheless, other simulation studies are focused on finite element method for modeling of electrical motors [14, 15].”
Dorrell, D. G., & Cossar, C. (2008) · IEEE Transactions on Magnetics · doi:10.1109/tmag.2008.2000498 · Cited by 42 · cited 1×
“The radial forces in static eccentricity condition produce a steady unbalancedmagnetic pull (UMP) in the radial route across the motor [33] due to the fact that the reluctance of the magnetic flux path decreases versus the transmission of flux on the side of tiny air-gap.”
BackgroundHyun, D., Hong, J., Lee, S. B., Kim, K.-H., Wiedenbrug, E. J., Teska, M., Nandi, S., & Chelvan, I. T. (2011) · IEEE Transactions on Industry Applications · doi:10.1109/tia.2011.2126010 · Cited by 39 · cited 1×
“Due to intrinsic eccentricity level of 10% which exists in practical condition [32], the eccentric motor in this study is modeled with 16.”
BackgroundFaiz, J., Tabatabaei, I., & Sharifi-Ghazvini, E. (2004) · Electromagnetics · doi:10.1080/02726340490467637 · Cited by 35
Dynamic eccentricity fault diagnosis in round rotor synchronous motors
Ebrahimi, B. M., Etemadrezaei, M., & Faiz, J. (2011) · Energy Conversion and Management · doi:10.1016/j.enconman.2010.12.017 · Cited by 28
Taher, S. A., & Malekpour, M. (2011) · Mathematical Problems in Engineering · doi:10.1155/2011/620689 · Cited by 24
Mehrjou, M. R. (2013) · International Journal of Applied Electronics in Physics & Robotics · doi:10.7575/aiac.ijaepr.v.1n.1p.18 · Cited by 6
Increase Performance of IPMSM by Combination of Maximum Torque per Ampere and Flux-Weakening Methods
Toosi, S., Mehrjou, M. R., Karami, M., & Zare, M. R. (2013) · ISRN Power Engineering · doi:10.1155/2013/187686 · Cited by 5 · cited 1×
“Electrical energy consumes great portion of resources owing to new developments in industries, growth of population, and changing of the human needs [1].”
BackgroundSelf-citation
Cited by
Fault Diagnosis and Fault-Tolerant Control of PMSM Drives–State of the Art and Future Challenges
Orlowska-Kowalska, T., Wolkiewicz, M., Pietrzak, P., Skowron, M., Ewert, P., Tarchala, G., Krzysztofiak, M., & Kowalski, C. T. (2022) · IEEE Access · doi:10.1109/access.2022.3180153 · Cited by 328
“The basic diagnostic signals in eccentricity diagnosis are: stator current [135], [143]-[146], [150], [151], [156]-[159], [161], [162], mechanical vibrations [149], [155], [156], noise [155], an airgap search coil voltage [149], [152], [156], [160], stator voltage [159], speed [159], load torque [159], d-axis stator i…”
BackgroundMethodFault detection of broken rotor bar in LS-PMSM using random forests
Quiroz, J. C., Mariun, N., Mehrjou, M. R., Izadi, M., Misron, N., & Mohd Radzi, M. A. (2018) · Measurement · doi:10.1016/j.measurement.2017.11.004 · Cited by 148
Self-citationBhuiyan, E. A., Akhand, M. M. A., Das, S. K., Ali, M. F., Tasneem, Z., Islam, M. R., Saha, D. K., Badal, F. R., Ahamed, M. H., & Moyeen, S. I. (2020) · International Journal of Automation and Computing · doi:10.1007/s11633-020-1250-3 · Cited by 68
“13 Algorithm flowchart of OA method[42]”
BackgroundMethodInfluentialLiu, F., Xiang, C., Liu, H., Chen, X., Feng, F., Hua, C., & Yu, K. (2021) · Mechanical Systems and Signal Processing · doi:10.1016/j.ymssp.2021.108740 · Cited by 30
Karami, M., Mariun, N., Kadir, M. Z. A. A., Misron, N., & Radzi, M. A. M. (2021) · Electric Power Components and Systems · doi:10.1080/15325008.2021.1937386 · Cited by 28
“Material characteristic and stator winding formation highly influence the fault detection criteria [9].”
BackgroundMethodSelf-citation
Metadata
- Authors
- Karami, M., Mariun, N., Rezazadeh Mehrjou, M., Ab Kadir, M. Z. A., Misron, N., & Mohd Radzi, M. A.
- Affiliations
- Universiti Putra Malaysia (MY)
- Corresponding author
- Karami, Mahdi
- Venue
- Mathematical Problems in Engineering
- Publisher
- Wiley
- Published
- 2014-01
- Volume
- 2014
- Issue
- 1
- ISSN
- 1024-123X (ISSN-L)
- 1563-5147
- OpenAlex
- W2171589637
- Cited by
- 31
- References
- 43
- Citations by year
- 2026: 1 · 2025: 1 · 2024: 2 · 2023: 4 · 2022: 3 · 2021: 6 · 2020: 4 · 2019: 2 · 2018: 4 · 2017: 2 · 2016: 1 · 2015: 1
- FWCI
- 0.71
- Type
- journal article
- Language
- en
- Open access
- hybrid
- doi.org
- Locations
- Mathematical Problems in Engineering (publishedVersion, cc-by)
- Universiti Putra Malaysia Institutional Repository (Universiti Putra Malaysia) (acceptedVersion)
- RePEc: Research Papers in Economics (submittedVersion)
- DOAJ (DOAJ: Directory of Open Access Journals) (submittedVersion)
- Funders
- Ministry of Education, Malaysia (FRGS-5524356)
- Universiti Putra Malaysia (FRGS-5524356)
- Topics
- Physical Sciences › Engineering › Electrical and Electronic Engineering › Electric Motor Design and Analysis
- Physical Sciences › Engineering › Control and Systems Engineering › Machine Fault Diagnosis Techniques
- Physical Sciences › Engineering › Electrical and Electronic Engineering › Sensorless Control of Electric Motors
- Keywords
- static eccentricity, fault diagnosis, line-start permanent magnet synchronous motor, three-phase induction motor, permeance, stator current signals, sideband harmonics, power spectral density, low-frequency harmonics, fault severity
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.