Noninvasive Techniques for Blood Pressure Measurement Are Not a Reliable Alternative to Direct Measurement: A Randomized Crossover Trial in ICU
Open accessThe DOI matches its Crossref record; 5 of the 5 references it cites were found in a registry or an index.
Abstract
Introduction.Noninvasive blood pressure (NIBP) monitoring methods are widely used in critically ill patients despite poor evidence of their accuracy. The erroneous interpretations of blood pressure (BP) may lead to clinical errors.Objectives.To test the accuracy and reliability of aneroid (ABP) and oscillometric (OBP) devices compared to the invasive BP (IBP) monitoring in an ICU population.Materials and Methods.Fifty adult patients (200 comparisons) were included in a randomized crossover trial. BP was recorded simultaneously by IBP and either by ABP or by OBP, taking IBP as gold standard.Results.Compared with ABP, IBP systolic values were significantly higher (mean difference ± standard deviation9.74±13.8;P<0.0001). Both diastolic (-5.13±7.1;P<0.0001) and mean (-2.14±7.1;P=0.0033) IBP were instead lower. Compared with OBP, systolic (10.80±14.9;P<0.0001) and mean (5.36±7.1;P<0.0001) IBP were higher, while diastolic IBP (-3.62±6.0;P<0.0001) was lower. Bland-Altman plots showed wide limits of agreement in both NIBP-IBP comparisons.Conclusions.BP measurements with different devices produced significantly different results. Since in critically ill patients the importance of BP readings is often crucial, noninvasive techniques cannot be regarded as reliable alternatives to direct measurements.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT
Martin Bland, J., & Altman, D. (1986) · The Lancet · doi:10.1016/s0140-6736(86)90837-8 · Cited by 47,965
Pickering, T. G., Hall, J. E., Appel, L. J., Falkner, B. E., Graves, J., Hill, M. N., Jones, D. W., Kurtz, T., Sheps, S. G., & Roccella, E. J. (2005) · Circulation · doi:10.1161/01.cir.0000154900.76284.f6 · Cited by 3,985
Pickering, T. G., Hall, J. E., Appel, L. J., Falkner, B. E., Graves, J., Hill, M. N., Jones, D. W., Kurtz, T., Sheps, S. G., & Roccella, E. J. (2005) · Hypertension · doi:10.1161/01.hyp.0000150859.47929.8e · Cited by 2,051
Bur, A., Hirschl, M. M., Herkner, H., Oschatz, E., Kofler, J., Woisetschläger, C., & Laggner, A. N. (2000) · Critical Care Medicine · doi:10.1097/00003246-200002000-00014 · Cited by 154 · cited 1×
“that underlying diseases do not contribute to the differences between differentmethods [34].”
BackgroundArterial blood pressure monitoring in overweight critically ill patients: invasive or noninvasive?
Araghi, A., Bander, J. J., & Guzman, J. A. (2006) · Critical Care · doi:10.1186/cc4896 · Cited by 115 · cited 1×
“This is a randomized crossover clinical trial performed to test the accuracy and reliability of ABP and OBP compared with invasive arterial blood pressure (IBP) monitoring.”
Method
Cited by
Kallioinen, N., Hill, A., Horswill, M. S., Ward, H. E., & Watson, M. O. (2017) · Journal of Hypertension · doi:10.1097/hjh.0000000000001197 · Cited by 357
Cuff-Less and Continuous Blood Pressure Monitoring: A Methodological Review
Sharma, M., Barbosa, K., Ho, V., Griggs, D., Ghirmai, T., Krishnan, S., Hsiai, T., Chiao, J.-C., & Cao, H. (2017) · Technologies · doi:10.3390/technologies5020021 · Cited by 226
Relationship between Hypotension and Cerebral Ischemia during Hemodialysis
MacEwen, C., Sutherland, S., Daly, J., Pugh, C., & Tarassenko, L. (2017) · Journal of the American Society of Nephrology · doi:10.1681/asn.2016060704 · Cited by 189
Ahuja, S., Mascha, E. J., Yang, D., Maheshwari, K., Cohen, B., Khanna, A. K., Ruetzler, K., Turan, A., & Sessler, D. I. (2020) · Anesthesiology · doi:10.1097/aln.0000000000003048 · Cited by 186
Peixoto, A. J. (2019) · New England Journal of Medicine · doi:10.1056/nejmcp1901117 · Cited by 166
Metadata
- Authors
- Ribezzo, S., Spina, E., Di Bartolomeo, S., & Sanson, G.
- Venue
- The Scientific World Journal
- Publisher
- Wiley
- Published
- 2014
- Volume
- 2014
- Pages
- 1-8
- ISSN
- 1537-744X (ISSN-L)
- 2356-6140
- OpenAlex
- W1988405807
- Cited by
- 83
- References
- 5
- FWCI
- 6.27
- Type
- journal article
- Language
- en
- Open access
- gold
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.