Recent Developments in Sweat Analysis and Its Applications
Open accessAbstract
Currently, the clinical use of sweat as biofluid is limited. The collection of sweat and its analysis for determining ethanol, drugs, ions, and metals have been encompassed in this review article to assess the merits of sweat compared to other biofluids, for example, blood or urine. Moreover, sweat comprises various biomarkers of different diseases including cystic fibrosis and diabetes. Additionally, the normalization of sampled volume of sweat is also necessary for getting efficient and useful results.
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
The concentration of chloride ions serves as a marker of cystic fibrosis and altered electrolyte levels correspond to a sodium ion imbalance.
“The concentration of chloride ions serves as a marker of cystic fibrosis and altered electrolyte levels correspond to a sodium ion imbalance (17).”
From A soft, wearable microfluidic device for the capture, storage, and colorimetric sensing of sweat (2016) · cites this paper as [17]
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Cites
Biology of sweat glands and their disorders. I. Normal sweat gland function
Sato, K., Kang, W. H., Saga, K., & Sato, K. T. (1989) · Journal of the American Academy of Dermatology · doi:10.1016/s0190-9622(89)70063-3 · Cited by 717 · see citing works
Correlation Between Sweat Glucose and Blood Glucose in Subjects with Diabetes
Moyer, J., Wilson, D., Finkelshtein, I., Wong, B., & Potts, R. (2012) · Diabetes Technology & Therapeutics · doi:10.1089/dia.2011.0262 · Cited by 570 · see citing works
Analyses of volatile organic compounds from human skin
Gallagher, M., Wysocki, C. J., Leyden, J. J., Spielman, A. I., Sun, X., & Preti, G. (2008) · British Journal of Dermatology · doi:10.1111/j.1365-2133.2008.08748.x · Cited by 438 · see citing works
Smartphone based health accessory for colorimetric detection of biomarkers in sweat and saliva
Oncescu, V., O’Dell, D., & Erickson, D. (2013) · Lab on a Chip · doi:10.1039/c3lc50431j · Cited by 362 · see citing works
A short history of sweat gland biology
Wilke, K., Martin, A. E., Terstegen, L., & Biel, S. S. (2007) · International Journal of Cosmetic Science · doi:10.1111/j.1467-2494.2007.00387.x · Cited by 333 · see citing works
Segura, J., Ventura, R., & Jurado, C. (1998) · Journal of Chromatography B Biomedical Sciences and Applications · doi:10.1016/s0378-4347(98)00089-9 · Cited by 251 · see citing works
Sweat: A sample with limited present applications and promising future in metabolomics
Mena-Bravo, A., & de Castro, M. D. L. (2013) · Journal of Pharmaceutical and Biomedical Analysis · doi:10.1016/j.jpba.2013.10.048 · Cited by 237 · see citing works
Alternative Specimens for Workplace Drug Testing*
Caplan, Y. H., & Goldberger, B. A. (2001) · Journal of Analytical Toxicology · doi:10.1093/jat/25.5.396 · Cited by 203 · see citing works
The role of alternative specimens in toxicological analysis
Gallardo, E., & Queiroz, J. A. (2008) · Biomedical Chromatography · doi:10.1002/bmc.1009 · Cited by 200 · see citing works
Kuukasjarvi, S. (2004) · Behavioral Ecology · doi:10.1093/beheco/arh050 · Cited by 165 · see citing works
Biological Matrices for the Evaluation of In Utero Exposure to Drugs of Abuse
Lozano, J., García‐Algar, Ó., Vall, O., de la Torre, R., Scaravelli, G., & Pichini, S. (2007) · Therapeutic Drug Monitoring · doi:10.1097/ftd.0b013e31815c14ce · Cited by 158 · see citing works
Clinical Pharmacokinetics of Amfetamine and Related Substances
de la Torre, R., Farr, M., Navarro, M., Pacifici, R., Zuccaro, P., & Pichini, S. (2004) · Clinical Pharmacokinetics · doi:10.2165/00003088-200443030-00002 · Cited by 149 · see citing works
Raiszadeh, M. M., Ross, M. M., Russo, P. S., Schaepper, M. A., Zhou, W., Deng, J., Ng, D., Dickson, A., Dickson, C., Strom, M., et al. (2012) · Journal of Proteome Research · doi:10.1021/pr2007957 · Cited by 142 · see citing works
Sweat testing for the diagnosis of cystic fibrosis: Practical considerations
LeGrys, V. A. (1996) · The Journal of Pediatrics · doi:10.1016/s0022-3476(96)70034-3 · Cited by 138 · see citing works
Samyn, N., & van Haeren, C. (2000) · International Journal of Legal Medicine · doi:10.1007/s004140050287 · Cited by 132 · see citing works
A neural survival factor is a candidate oncogene in breast cancer
PORTER, D. A., Weremowicz, S., Chin, K., Seth, P., Keshaviah, A. P., Lahti‐Domenici, J., Bae, Y. K., Monitto, C. L., Merlos-Suarez, A., Chan, J. A.-W., et al. (2003) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.1932980100 · Cited by 130 · see citing works
Blood, Urine, and Sweat (BUS) Study: Monitoring and Elimination of Bioaccumulated Toxic Elements
Genuis, S. J., Birkholz, D., Rodushkin, I., & Beesoon, S. (2011) · Archives of Environmental Contamination and Toxicology · doi:10.1007/s00244-010-9611-5 · Cited by 128 · cited 1× · see citing works
“, 2011 [20]”
Sweat testing for cocaine, codeine and metabolites by gas chromatography–mass spectrometry
Huestis, M. A., Oyler, J. M., Cone, E. J., Wstadik, A. T., Schoendorfer, D., & Joseph, R. E. (1999) · Journal of Chromatography B Biomedical Sciences and Applications · doi:10.1016/s0378-4347(99)00246-7 · Cited by 125 · see citing works
Hassan, M. I., Waheed, A., Yadav, S., Singh, T. P., & Ahmad, F. (2008) · Cellular and Molecular Life Sciences · doi:10.1007/s00018-008-8463-x · Cited by 122 · see citing works
Drug Monitoring in Nonconventional Biological Fluids and Matrices
Pichini, S., Altieri, I., Zuccaro, P., & Pacifici, R. (1996) · Clinical Pharmacokinetics · doi:10.2165/00003088-199630030-00003 · Cited by 120 · see citing works
Sweat Testing in Opioid Users with a Sweat Patch
Kintz, P., Tracqui, A., Mangin, P., & Edel, Y. (1996) · Journal of Analytical Toxicology · doi:10.1093/jat/20.6.393 · Cited by 119 · see citing works
The Use of Oral Fluid and Sweat Wipes for the Detection of Drugs of Abuse in Drivers
Samyn, N., Boeck, G. D., & Verstraete, A. (2002) · Journal of Forensic Sciences · doi:10.1520/jfs15579j · Cited by 114 · see citing works
Individual discrimination of humans by odor
WALLACE, P. M. (1977) · Physiology & Behavior · doi:10.1016/0031-9384(77)90238-4 · Cited by 114 · see citing works
Sikirzhytski, V., Sikirzhytskaya, A., & Lednev, I. K. (2012) · Analytica Chimica Acta · doi:10.1016/j.aca.2011.12.059 · Cited by 106 · see citing works
Analyzing and Mapping Sweat Metabolomics by High-Resolution NMR Spectroscopy
Kutyshenko, V. P., Molchanov, M. V., Beskaravayny, P., Uversky, V. N., & Timchenko, M. (2011) · PLoS ONE · doi:10.1371/journal.pone.0028824 · Cited by 98 · see citing works
Hohnadel, D. C., Sunderman, F. W., Nechay, M. W., & McNeely, M. (1973) · Clinical Chemistry · doi:10.1093/clinchem/19.11.1288 · Cited by 96 · see citing works
Monitoring Opiate Use in Substance Abuse Treatment Patients With Sweat and Urine Drug Testing
Huestis, M. A., Cone, E. J., Wong, C. J., Umbricht, A., & Preston, K. L. (2000) · Journal of Analytical Toxicology · doi:10.1093/jat/24.7.509 · Cited by 94 · see citing works
Rowe, S. M., Accurso, F. J., & Clancy, J. P. (2007) · Proceedings of the American Thoracic Society · doi:10.1513/pats.200703-043br · Cited by 87 · see citing works
Sweat‐testing: A review of current technical requirements
Beauchamp, M. K., & Lands, L. C. (2005) · Pediatric Pulmonology · doi:10.1002/ppul.20226 · Cited by 84 · see citing works
A simple new non‐invasive sweat indicator test for the diagnosis of diabetic neuropathy
Παπάνας, Ν., Boulton, A. J. M., Malik, R. A., Manes, C., Schnell, O., Spallone, V., Tentolouris, N., Tesfaye, S. H., Valensi, P. E., Ziegler, D., et al. (2012) · Diabetic Medicine · doi:10.1111/dme.12000 · Cited by 83 · see citing works
Kuhn, F., & Natsch, A. (2008) · Journal of The Royal Society Interface · doi:10.1098/rsif.2008.0223 · Cited by 80 · see citing works
THE EXCRETION OF TRACE METALS IN HUMAN SWEAT
COHN, J. R., & EMMETT, E. A. (1979) · Toxicology and Occupational Medicine · doi:10.1016/b978-0-444-00288-4.50036-0 · Cited by 78 · see citing works
Systems biology approaches to evaluate arsenic toxicity and carcinogenicity: An overview
Bhattacharjee, P., Chatterjee, D., Singh, K. K., & Giri, A. K. (2013) · International Journal of Hygiene and Environmental Health · doi:10.1016/j.ijheh.2012.12.008 · Cited by 77 · see citing works
Myint, K. T., Aoshima, K., Tanaka, S., Nakamura, T., & Oda, Y. (2009) · Analytical Chemistry · doi:10.1021/ac802259r · Cited by 71 · see citing works
The use of sweat to monitor lead absorption through the skin
Lilley, S. G., Florence, T. M., & Stauber, J. L. (1988) · The Science of The Total Environment · doi:10.1016/0048-9697(88)90112-x · Cited by 70 · see citing works
Brunet, B., Barnes, A. J., Scheidweiler, K. B., Mura, P., & Huestis, M. A. (2008) · Analytical and Bioanalytical Chemistry · doi:10.1007/s00216-008-2228-0 · Cited by 70 · see citing works
Usefulness of Sweat Testing for the Detection of MDMA after a Single-Dose Administration*
Pichini, S., Navarro, M. D. S., Pacifici, R., Zuccaro, P., Ortuño, J., Farré, M., Roset, P. N., Segura, J., & de la Torre, R. (2003) · Journal of Analytical Toxicology · doi:10.1093/jat/27.5.294 · Cited by 66 · see citing works
Susceptibility of PharmChek™ drugs of abuse patch to environmental contamination
Kidwell, D. A., & Smith, F. P. (2001) · Forensic Science International · doi:10.1016/s0379-0738(00)00353-4 · Cited by 65 · see citing works
Staub, C. (1999) · Journal of Chromatography B Biomedical Sciences and Applications · doi:10.1016/s0378-4347(99)00249-2 · Cited by 65 · see citing works
Excretion of Δ9-tetrahydrocannabinol in sweat
Huestis, M. A., Scheidweiler, K. B., Saito, T., Fortner, N. A., Abraham, T. T., Gustafson, R. A., & Smith, M. L. (2007) · Forensic Science International · doi:10.1016/j.forsciint.2007.04.002 · Cited by 58 · see citing works
Lead in sweat and its relationship to salivary and urinary levels in normal healthy subjects1
Omokhodion, F. O., & Crockford, G. W. (1991) · The Science of The Total Environment · doi:10.1016/0048-9697(91)90137-4 · Cited by 57 · see citing works
A comparative study of copper, lead, cadmium and zinc in human sweat and blood
Stauber, J. L., & Florence, T. M. (1988) · The Science of The Total Environment · doi:10.1016/0048-9697(88)90140-4 · Cited by 55 · see citing works
Barroso, M., Gallardo, E., Vieira, D. N., Queiroz, J. A., & López‐Rivadulla, M. (2011) · Analytical and Bioanalytical Chemistry · doi:10.1007/s00216-011-4888-4 · Cited by 49 · see citing works
Appenzeller, B. M. R., Schummer, C., Rodrigues, S. B., & Wennig, R. (2007) · Journal of Chromatography B · doi:10.1016/j.jchromb.2007.01.037 · Cited by 48 · see citing works
Opioid Disposition in Human Sweat after Controlled Oral Codeine Administration
Schwilke, E. W., Barnes, A. J., Kacinko, S. L., Cone, E. J., Moolchan, E. T., & Huestis, M. A. (2006) · Clinical Chemistry · doi:10.1373/clinchem.2006.067983 · Cited by 48 · see citing works
LC‐MS: a powerful tool in workplace drug testing
Gallardo, E., Barroso, M., & Queiroz, J. A. (2009) · Drug Testing and Analysis · doi:10.1002/dta.26 · Cited by 44 · see citing works
Uemura, N., Nath, R. P., Harkey, M. R., Henderson, G. L., Mendelson, J. E., & Jones, R. T. (2004) · Journal of Analytical Toxicology · doi:10.1093/jat/28.4.253 · Cited by 43 · see citing works
Determination of Fentanyl in Sweat and Hair of a Patient using Transdermal Patches
Schneider, S., Ait-m-bark, Z., Schummer, C., Lemmer, P., Yegles, M., Appenzeller, B. M. R., & Wennig, R. (2008) · Journal of Analytical Toxicology · doi:10.1093/jat/32.3.260 · Cited by 41 · see citing works
Trace elements in the sweat of acclimatized persons
Omokhodion, F. O., & Howard, J. M. (1994) · Clinica Chimica Acta · doi:10.1016/0009-8981(94)90250-x · Cited by 40 · see citing works
Monitoring Pregnant Women's Illicit Opiate and Cocaine Use With Sweat Testing
Brunet, B., Barnes, A. J., Choo, R. E., Mura, P., Jones, H. E., & Huestis, M. A. (2010) · Therapeutic Drug Monitoring · doi:10.1097/ftd.0b013e3181c13aaf · Cited by 38 · see citing works
Cytosolic potassium controls CFTR deactivation in human sweat duct
Reddy, M. M., & Quinton, P. (2006) · American Journal of Physiology-Cell Physiology · doi:10.1152/ajpcell.00134.2005 · Cited by 32 · see citing works
Protocolo de diagnóstico y seguimiento de los pacientes con fibrosis quística
de Agüero, M. I. B. G., Hernández, G. G., & Gärtner, S. (2009) · Anales de Pediatría · doi:10.1016/j.anpedi.2009.06.020 · Cited by 31 · see citing works
Usefulness of Sweat Testing for the Detection of Cannabis Smoke
de la Torre, R., & Pichini, S. (2004) · Clinical Chemistry · doi:10.1373/clinchem.2004.040758 · Cited by 30 · see citing works
Sweat testing in addicts under methadone treatment: An Italian experience
Fucci, N., Giovanni, N. D., & Scarlata, S. (2007) · Forensic Science International · doi:10.1016/j.forsciint.2007.03.010 · Cited by 28 · see citing works
Methadone in Hair and Sweat From Patients in Long-Term Maintenance Therapy
Fucci, N., & Giovanni, N. D. (2007) · Therapeutic Drug Monitoring · doi:10.1097/ftd.0b013e31811f1bbe · Cited by 28 · see citing works
Evaluation of the Megaduct sweat collector for mineral analysis
Ely, M. R., Ely, B. R., Chinevere, T. D., Lacher, C. P., Lukaski, H. C., & Cheuvront, S. N. (2012) · Physiological Measurement · doi:10.1088/0967-3334/33/3/385 · Cited by 26 · see citing works
The determination of trace metals in sweat by anodic stripping voltammetry
Stauber, J. L., & Florence, T. M. (1987) · The Science of The Total Environment · doi:10.1016/0048-9697(87)90420-7 · Cited by 25 · see citing works
Hb, L., Zg, B., & Tr, V. (1973) · PubMed · Cited by 20 · see citing works
Omokhodion, F. O., & Howard, J. (1991) · The Science of The Total Environment · doi:10.1016/0048-9697(91)90138-5 · Cited by 19 · see citing works
Clinical response to therapeutic agents in poisoning from mercury vapor.
Sunderman, F. W. (1978) · PubMed · Cited by 19 · see citing works
Mercury exposure evaluations and their correlation with urine mercury excretions.
Zg, B., Mw, W., & Kuryla, L. A. (1973) · PubMed · Cited by 19 · see citing works
Yousuf, A. K. M., Misbahuddin, M., & Rahman, M. S. (2011) · Clinical Toxicology · doi:10.3109/15563650.2011.577747 · Cited by 12 · see citing works
Omokhodion, F. O., & Crockford, G. W. (1991) · The Science of The Total Environment · doi:10.1016/0048-9697(91)90360-q · Cited by 7 · see citing works
The Direct Determination of Mercury in Sweat
Robinson, J. W., & Skelly, E. M. (1983) · Spectroscopy Letters · doi:10.1080/00387018308062329 · Cited by 5 · see citing works
Parpaleĭ, I. A., Prokof'eva, L. G., & Obertas, V. G. (1991) · PubMed · Cited by 5 · see citing works
Robinson, J. W., & Weiss, S. (1980) · Journal of Environmental Science and Health Part A Environmental Science and Engineering · doi:10.1080/10934528009374956 · Cited by 4 · see citing works
Analysis of Cancer Biomarkers in Exhaled Breath and Comparison with Sensory Indications by Dogs
Buszewski, B., Ligor, T., Rudnicka, J., Jezierski, T. A., Walczak, M., & Wenda-Piesik, A. (2013) · Elsevier eBooks · doi:10.1016/b978-0-44-462613-4.00010-6 · Cited by 4 · see citing works
Flagged first, then by citations
Research works printed but not linked: 2
- [38]Kintz P. Samy N. Bogusz M. J. Unconventional samples and alternative matrices Handbook of Analytical Separations 2000 2 Amsterdam, The Netherlands Elsevier Science 459 488
- [45]Pichini S. Distribution of 3,4-methylenedioxymethamphetamine (MDMA) in non conventional matrices and its applications in clinical toxicology [Thesis] 2005 Autonomous University of Barcelona
Cited by
Sorted by citations
A soft, wearable microfluidic device for the capture, storage, and colorimetric sensing of sweat
Koh, A., Kang, D., Xue, Y., Lee, S., Pielak, R. M., Kim, J., Hwang, T., Min, S., Banks, A., Bastien, P., et al. (2016) · Science Translational Medicine · doi:10.1126/scitranslmed.aaf2593 · Cited by 1,308 · see citing works
Wearable and flexible electrochemical sensors for sweat analysis: a review
Gao, F., Liu, C., Zhang, L., Liu, T., Wang, Z., Song, Z., Cai, H., Fang, Z., Chen, J., Wang, J., et al. (2022) · Microsystems & Nanoengineering · doi:10.1038/s41378-022-00443-6 · Cited by 813 · see citing works
Skin-Interfaced Wearable Sweat Sensors for Precision Medicine
Min, J., Tu, J., Xu, C., Lukas, H., Shin, S., Yang, Y., Solomon, S. A., Mukasa, D., & Gao, W. F. (2023) · Chemical Reviews · doi:10.1021/acs.chemrev.2c00823 · Cited by 728 · see citing works
Ghoneim, M. T., Nguyen, A. N., Dereje, N., Huang, J., Moore, G. C., Murzynowski, P. J., & Dağdeviren, C. (2019) · Chemical Reviews · doi:10.1021/acs.chemrev.8b00655 · Cited by 319 · see citing works
Promphet, N., Rattanawaleedirojn, P., Siralertmukul, K., Soatthiyanon, N., Potiyaraj, P., Thanawattano, C., Hinestroza, J. P., & Rodthongkum, N. (2018) · Talanta · doi:10.1016/j.talanta.2018.09.086 · Cited by 254 · see citing works
Laser-induced graphene non-enzymatic glucose sensors for on-body measurements
Zhu, J., Liu, S., Hu, Z., Zhang, X., Yi, N., Tang, K., Dexheimer, M. G., Lian, X. L., Wang, Q., Yang, J. Y., et al. (2021) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2021.113606 · Cited by 237 · see citing works
Flexible inorganic bioelectronics
Chen, Y., Zhang, Y., Liang, Z., Cao, Y. K., Han, Z., & Feng, X. (2020) · npj Flexible Electronics · doi:10.1038/s41528-020-0065-1 · Cited by 231 · see citing works
Textile Organic Electrochemical Transistors as a Platform for Wearable Biosensors
Gualandi, I., Marzocchi, M., Achilli, A., Cavedale, D., Bonfiglió, A., & Fraboni, B. (2016) · Scientific Reports · doi:10.1038/srep33637 · Cited by 193 · see citing works
Keene, S. T., Fogarty, D., Cooke, R., Casadevall, C., Salleo, A., & Parlak, O. (2019) · Advanced Healthcare Materials · doi:10.1002/adhm.201901321 · Cited by 185 · see citing works
Kim, S. B., Zhang, Y., Won, S. M., Bandodkar, A. J., Sekine, Y., Xue, Y., Koo, J., Harshman, S. W., Martin, J. A., Park, J. M., et al. (2018) · Small · doi:10.1002/smll.201703334 · Cited by 167 · see citing works
Printing Flexible and Hybrid Electronics for Human Skin and Eye‐Interfaced Health Monitoring Systems
Kim, K., Kim, B., & Lee, C. H. (2019) · Advanced Materials · doi:10.1002/adma.201902051 · Cited by 146 · see citing works
Padmanathan, N., Shao, H., & Razeeb, K. M. (2018) · ACS Applied Materials & Interfaces · doi:10.1021/acsami.7b17187 · Cited by 147 · see citing works
Chung, M., Skinner, W. H., Robert, C., Campbell, C. J., Rossi, R. M., Koutsos, V., & Radacsi, N. (2021) · ACS Applied Materials & Interfaces · doi:10.1021/acsami.1c15238 · Cited by 143 · see citing works
Non-invasive wearable chemical sensors in real-life applications
Promphet, N., Ummartyotin, S., Ngeontae, W., Puthongkham, P., & Rodthongkum, N. (2021) · Analytica Chimica Acta · doi:10.1016/j.aca.2021.338643 · Cited by 138 · see citing works
Alternative matrices in forensic toxicology: a critical review
de Campos, E. G., da Costa, B. R. B., dos Santos, F. S., Monedeiro, F., Alves, M. N. R., Santos, W. J. R., & Martinis, B. S. D. (2021) · Forensic Toxicology · doi:10.1007/s11419-021-00596-5 · Cited by 137 · see citing works
Siripongpreda, T., Somchob, B., Rodthongkum, N., & Hoven, V. P. (2020) · Carbohydrate Polymers · doi:10.1016/j.carbpol.2020.117506 · Cited by 130 · see citing works
Kim, J., Wu, Y., Luan, H., Yang, D. S., Cho, D., Kwak, S. S., Liu, S., Ryu, H., Ghaffari, R., & Rogers, J. A. (2021) · Advanced Science · doi:10.1002/advs.202103331 · Cited by 128 · see citing works
Proteomic Profiling of Sweat Exosome Suggests its Involvement in Skin Immunity.
Wu, C.-X., & Liu, Z.-F. (2018) · Journal of Investigative Dermatology · doi:10.1016/j.jid.2017.05.040 · Cited by 104 · see citing works
Wang, W., Chen, Y., Xiao, C., Xiao, S., Wang, C., Nie, Q., Xu, P., Chen, J., You, R., Zhang, G., et al. (2023) · Chemical Engineering Journal · doi:10.1016/j.cej.2023.145953 · Cited by 116 · see citing works
Xiao, J., Fan, C. G., Xu, T., Su, L., & Zhang, X. (2022) · Sensors and Actuators B Chemical · doi:10.1016/j.snb.2022.131586 · Cited by 115 · see citing works
Cancer biomarkers and their biosensors: A comprehensive review
Khan, H., Shah, M. R., Barek, J., & Malik, M. I. (2022) · TrAC Trends in Analytical Chemistry · doi:10.1016/j.trac.2022.116813 · Cited by 107 · see citing works
Zhou, Z., & Zare, R. N. (2017) · Analytical Chemistry · doi:10.1021/acs.analchem.6b04498 · Cited by 104 · see citing works
Nanomaterials-patterned flexible electrodes for wearable health monitoring: a review
Hasan, M. M., & Hossain, M. M. (2021) · Journal of Materials Science · doi:10.1007/s10853-021-06248-8 · Cited by 103 · see citing works
Finger sweat analysis enables short interval metabolic biomonitoring in humans
Brunmair, J., Gotsmy, M., Niederstaetter, L., Neuditschko, B., Bileck, A., Slany, A., Feuerstein, M. L., Langbauer, C., Janker, L., Zanghellini, J., et al. (2021) · Nature Communications · doi:10.1038/s41467-021-26245-4 · Cited by 96 · see citing works
Zhao, Z., Li, Q., Chen, L., Yu, Z., Gong, J., Li, Z., & Zhang, J. (2020) · Lab on a Chip · doi:10.1039/d0lc01075h · Cited by 95 · see citing works
PEDOT: Dye-Based, Flexible Organic Electrochemical Transistor for Highly Sensitive pH Monitoring
Mariani, F., Gualandi, I., Tessarolo, M., Fraboni, B., & Scavetta, E. (2018) · ACS Applied Materials & Interfaces · doi:10.1021/acsami.8b04970 · Cited by 92 · see citing works
Forensics in hand: new trends in forensic devices (2013–2017)
de Oliveira, L. P., Rocha, D. P., de Araujo, W. R., Muñoz, R. A. A., Paixão, T. R. L. C., & Salles, M. O. (2018) · Analytical Methods · doi:10.1039/c8ay01389f · Cited by 90 · see citing works
Trovato, V., Sfameni, S., Rando, G., Rosace, G., Libertino, S., Ferri, A., & Plutino, M. R. (2022) · Molecules · doi:10.3390/molecules27175709 · Cited by 91 · see citing works
Wearable Sensor System Powered by a Biofuel Cell for Detection of Lactate Levels in Sweat
Garcia, S. O., Ulyanova, Y., Figueroa-Teran, R., Bhatt, K. H., Singhal, S., & Atanassov, P. B. (2016) · ECS Journal of Solid State Science and Technology · doi:10.1149/2.0131608jss · Cited by 88 · see citing works
Wearable piezoelectric mass sensor based on pH sensitive hydrogels for sweat pH monitoring
Scarpa, E., Mastronardi, V., Guido, F., Algieri, L., Qualtieri, A., Fiammengo, R., Rizzi, F., & Vittorio, M. D. (2020) · Scientific Reports · doi:10.1038/s41598-020-67706-y · Cited by 87 · see citing works
Eccrine Sweat as a Biofluid for Profiling Immune Biomarkers
Katchman, B. A., Zhu, M., Blain Christen, J., & Anderson, K. S. (2018) · PROTEOMICS – Clinical Applications · doi:10.1002/prca.201800010 · Cited by 86 · see citing works
Das, R., Nag, S., & Banerjee, P. (2023) · Molecules · doi:10.3390/molecules28031259 · Cited by 89 · see citing works
Bauer, M., Wunderlich, L., Weinzierl, F., Lei, Y., Duerkop, A., Alshareef, H. N., & Baeumner, A. J. (2020) · Analytical and Bioanalytical Chemistry · doi:10.1007/s00216-020-02939-4 · Cited by 85 · see citing works
Wearable multifunctional sweat-sensing system for efficient healthcare monitoring
Criscuolo, F., Hanitra, I. N., Aiassa, S., Taurino, I., Oliva, N., Carrara, S., & Micheli, G. D. (2020) · Sensors and Actuators B Chemical · doi:10.1016/j.snb.2020.129017 · Cited by 85 · see citing works
Microfluidics by Additive Manufacturing for Wearable Biosensors: A Review
Padash, M., Enz, C., & Carrara, S. (2020) · Sensors · doi:10.3390/s20154236 · Cited by 87 · see citing works
Vibrational Spectroscopy for Identification of Metabolites in Biologic Samples
Hackshaw, K. V., Miller, J. S., Aykas, D. P., & RODRIGUEZ‐SAONA, L. E. (2020) · Molecules · doi:10.3390/molecules25204725 · Cited by 83 · see citing works
Clark, K. M., & Ray, T. R. (2023) · ACS Sensors · doi:10.1021/acssensors.3c01512 · Cited by 86 · see citing works
UV‐Sensitive Wearable Devices for Colorimetric Monitoring of UV Exposure
Kurz, W., Yetisen, A. K., Kaito, M. V., Fuchter, M. J., Jakobi, M., Elsner, M., & Koch, A. W. (2020) · Advanced Optical Materials · doi:10.1002/adom.201901969 · Cited by 82 · see citing works
Textile Chemical Sensors Based on Conductive Polymers for the Analysis of Sweat
Gualandi, I., Tessarolo, M., Mariani, F., Possanzini, L., Scavetta, E., & Fraboni, B. (2021) · Polymers · doi:10.3390/polym13060894 · Cited by 80 · see citing works
Assalve, G., Lunetti, P., di Cagno, A., Luca, E. W. D., Aldegheri, S., Zara, V., & Ferramosca, A. (2024) · Biosensors · doi:10.3390/bios14120574 · Cited by 85 · see citing works
(2017) · PubMed Central · Cited by 76 · see citing works
Coates, M., Mariottoni, P. R. C. G. B., Corcoran, D. L., Fradin, H., Jaleel, T., Brown, D. A., Brooks, S. R., Murray, J. C. S., Morasso, M. I., & MacLeod, A. S. (2019) · PLoS ONE · doi:10.1371/journal.pone.0216249 · Cited by 74 · see citing works
Present and foreseeable future of metabolomics in forensic analysis
Castillo-Peinado, L. S., & de Castro, M. D. L. (2016) · Analytica Chimica Acta · doi:10.1016/j.aca.2016.04.040 · Cited by 77 · see citing works
Silicon Micropillar Array-Based Wearable Sweat Glucose Sensor
Dervisevic, M., Alba, M., Esser, L., Tabassum, N. H., Prieto‐Simón, B., & Voelcker, N. H. (2021) · ACS Applied Materials & Interfaces · doi:10.1021/acsami.1c22383 · Cited by 75 · see citing works
Toilet-based continuous health monitoring using urine
Taşoğlu, S. (2022) · Nature Reviews Urology · doi:10.1038/s41585-021-00558-x · Cited by 79 · see citing works
Hussain, S., & Park, S. (2020) · ACS Sensors · doi:10.1021/acssensors.0c01757 · Cited by 71 · see citing works
Acevedo, C. M. D., Gómez, J. K. C., & Rojas, C. A. A. (2021) · Biomedical Signal Processing and Control · doi:10.1016/j.bspc.2021.102756 · Cited by 71 · see citing works
Liu, D., Liu, Z., Feng, S., Gao, Z., Chen, R., Cai, G., & Bian, S. (2023) · Biosensors · doi:10.3390/bios13020157 · Cited by 68 · see citing works
Usability as a guiding principle for the design of paper-based, point-of-care devices – A review
Murray, L. P., & Mace, C. R. (2020) · Analytica Chimica Acta · doi:10.1016/j.aca.2020.09.063 · Cited by 66 · see citing works
Chen, Y., Kuan, W., & Liu, C. (2020) · International Journal of Environmental Research and Public Health · doi:10.3390/ijerph17103377 · Cited by 65 · see citing works
Lee, C., Jeong, S., Kwon, Y., Lee, J.-U., Cho, S., & Shin, B. S. (2021) · Sensors and Actuators A Physical · doi:10.1016/j.sna.2021.113320 · Cited by 64 · see citing works
Nair, R. R., An, J. M., Kim, J., & Kim, D. (2023) · Coordination Chemistry Reviews · doi:10.1016/j.ccr.2023.215336 · Cited by 65 · see citing works
Liu, T.-L., Dong, Y., Chen, S., Zhou, J., Ma, Z., & Li, J. (2022) · Science Advances · doi:10.1126/sciadv.abo7049 · Cited by 63 · see citing works
Review and Comparison of Cancer Biomarker Trends in Urine as a Basis for New Diagnostic Pathways
Bax, C., Lotesoriere, B. J., Sironi, S., & Capelli, L. (2019) · Cancers · doi:10.3390/cancers11091244 · Cited by 63 · see citing works
Mugo, S. M., Robertson, S. V., & Lu, W. (2023) · Talanta · doi:10.1016/j.talanta.2023.124531 · Cited by 61 · see citing works
Cutting Edge Methods for Non-Invasive Disease Diagnosis Using E-Tongue and E-Nose Devices
Fitzgerald, J. E., & Fenniri, H. (2017) · Biosensors · doi:10.3390/bios7040059 · Cited by 61 · see citing works
Laser‐Induced, Green and Biocompatible Paper‐Based Devices for Circular Electronics
Cantarella, G., Madagalam, M., Merino, I., Ebner, C., Ciocca, M., Polo, A., Ibba, P., Bettotti, P., Ahmad, M., Shkodra, B., et al. (2023) · Advanced Functional Materials · doi:10.1002/adfm.202210422 · Cited by 55 · see citing works
Vairo, D., Bruzzese, L., Marlinge, M., Fuster, L., Adjriou, N., Kipson, N., Brunet, P., Cautela, J., Jammes, Y., Mottola, G., et al. (2017) · Scientific Reports · doi:10.1038/s41598-017-12211-y · Cited by 55 · see citing works
Self-powered wearable electronics
Tan, P., Zou, Y., Fan, Y., & Li, Z. (2020) · Wearable Technologies · doi:10.1017/wtc.2020.3 · Cited by 56 · see citing works
Harshman, S. W., Pitsch, R. L., Smith, Z. K., O’Connor, M. L., Geier, B. A., Qualley, A. V., Schaeublin, N. M., Fischer, M. V., Eckerle, J. J., Strang, A. J., et al. (2018) · PLOS ONE · doi:10.1371/journal.pone.0203133 · Cited by 51 · see citing works
Zhang, X., Yao, B., Hu, Q., Hong, Y., Wallace, A. K., Reynolds, K. J., Ramsey, C., Maeder, A. J., Reed, R. L., & Tang, Y. (2020) · Materials Chemistry Frontiers · doi:10.1039/d0qm00376j · Cited by 49 · see citing works
Conducting polymers in wearable devices
Mokhtar, S. M. A., de Eulate, E. A., Yamada, M., Prow, T. W., & Evans, D. (2020) · Medical Devices & Sensors · doi:10.1002/mds3.10160 · Cited by 48 · see citing works
Wearable electronic nose for human skin odor identification: A preliminary study
Zheng, Y., Li, H., Shen, W., & Jian, J. (2018) · Sensors and Actuators A Physical · doi:10.1016/j.sna.2018.11.048 · Cited by 46 · see citing works
Validating Differential Volatilome Profiles in Parkinson’s Disease
Sinclair, E., Walton‐Doyle, C., Sarkar, D., Hollywood, K. A., Milne, J., Lim, S. H., Kunath, T., Rijs, A. M., de Bie, R. M. A., Silverdale, M., et al. (2021) · ACS Central Science · doi:10.1021/acscentsci.0c01028 · Cited by 44 · see citing works
Green sample preparation of alternative biosamples in forensic toxicology
Manousi, N., & Samanidou, V. (2021) · Sustainable Chemistry and Pharmacy · doi:10.1016/j.scp.2021.100388 · Cited by 41 · see citing works
Iakab, S. A., Ràfols, P., Correig, X., & García‐Altares, M. (2021) · Analytical Chemistry · doi:10.1021/acs.analchem.0c04986 · Cited by 41 · see citing works
Wearable microneedle dual electrochemical sensor for simultaneous pH and cortisol detection in sweat
Mugo, S. M., Lu, W., Wood, M., & Lemieux, S. (2021) · Electrochemical Science Advances · doi:10.1002/elsa.202100039 · Cited by 40 · see citing works
Wearable Double Network Plasmonic Hydrogel for SERS Detection of Urea and Uric Acid in Sweat
Zhu, J., Yu, W., Xiong, H., Xia, X., Li, Y., & Huang, Y. (2025) · ACS Sensors · doi:10.1021/acssensors.5c01745 · Cited by 41 · see citing works
A Biomimetric Lactate Imprinted Smart Polymers as Capacitive Sweat Sensors
Mugo, S. M., Dhanjai, D., & Alberkant, J. (2020) · IEEE Sensors Journal · doi:10.1109/jsen.2020.2974851 · Cited by 38 · see citing works
Probing Skin for Metabolites and Topical Drugs with Hydrogel Micropatches
Dutkiewicz, E. P., Chiu, H., & Urban, P. L. (2017) · Analytical Chemistry · doi:10.1021/acs.analchem.6b04276 · Cited by 37 · see citing works
Optical sensors for transdermal biomarker detection: A review
Amjad, A., & Xian, X. (2024) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2024.116844 · Cited by 37 · see citing works
Rood, J. J. M., Schellens, J. H. M., Beijnen, J. H., & Sparidans, R. W. (2016) · Journal of Pharmaceutical and Biomedical Analysis · doi:10.1016/j.jpba.2016.06.037 · Cited by 36 · see citing works
Quantitative mass spectrometry of unconventional human biological matrices
Dutkiewicz, E. P., & Urban, P. L. (2016) · Philosophical Transactions of the Royal Society A Mathematical Physical and Engineering Sciences · doi:10.1098/rsta.2015.0380 · Cited by 36 · see citing works
Na, C. H., Sharma, N., Madugundu, A. K., Chen, R., Aksit, M. A., Rosson, G. D., Cutting, G. R., & Pandey, A. (2019) · Molecular & Cellular Proteomics · doi:10.1074/mcp.ra118.001101 · Cited by 36 · see citing works
Real Time Analysis of Bioanalytes in Healthcare, Food, Zoology and Botany
Wang, T., Ramnarayanan, A., & Cheng, H. (2017) · Sensors · doi:10.3390/s18010005 · Cited by 34 · see citing works
Rodin, D., Kirby, M. L., Sedogin, N., Shapiro, Y., Pinhasov, A., & Kreinin, A. (2019) · Clinical Biochemistry · doi:10.1016/j.clinbiochem.2018.12.014 · Cited by 34 · see citing works
Sweat urea bioassay based on degradation of Prussian Blue as the sensing architecture
Salatiello, S., Spinelli, M., Cassiano, C., Amoresano, A., Marini, F., & Cinti, S. (2022) · Analytica Chimica Acta · doi:10.1016/j.aca.2022.339882 · Cited by 33 · see citing works
Multimodal technique to eliminate humidity interference for specific detection of ethanol
Jalal, A. H., Umasankar, Y., Gonzalez, P. J., Alfonso, A. A., & Bhansali, S. (2016) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2016.08.106 · Cited by 33 · see citing works
Screening of Potential Stress Biomarkers in Sweat Associated with Sports Training
Nunes, M. J., Cordas, C. M., Moura, J. J. G., Noronha, J. P., & Branco, L. C. (2021) · Sports Medicine - Open · doi:10.1186/s40798-020-00294-3 · Cited by 34 · see citing works
Moisture-Associated Skin Damage
Gray, M., Bliss, D. Z., & McNichol, L. (2022) · Journal of Wound Ostomy and Continence Nursing · doi:10.1097/won.0000000000000865 · Cited by 33 · see citing works
Gould, O., Nguyen, N., & Honeychurch, K. C. (2023) · Chemosensors · doi:10.3390/chemosensors11100527 · Cited by 31 · see citing works
Serag, A., Shakkour, Z., Halboup, A. M., Kobeissy, F. H., & Farag, M. A. (2021) · Journal of Proteomics · doi:10.1016/j.jprot.2021.104310 · Cited by 32 · see citing works
Micropatternable Janus Paper as a Wearable Skin Patch for Sweat Collection and Analysis
Gao, Y., & Choi, S. (2023) · Advanced Materials Technologies · doi:10.1002/admt.202300396 · Cited by 28 · see citing works
Zhao, G., Li, Z.-Y., Huang, X., Zhang, Q., Liu, Y., & Yu, X. (2024) · Soft Science · doi:10.20517/ss.2024.04 · Cited by 28 · see citing works
Hauke, A., Oertel, S., Knoke, L., Fein, V., Maier, C., Brinkmann, F., & Jank, M. P. M. (2020) · Biosensors · doi:10.3390/bios10090123 · Cited by 28 · see citing works
Brunmair, J., Bileck, A., Stimpfl, T., Raible, F., Favero, G. D., Meier, S. M., & Gerner, C. (2021) · The EPMA Journal · doi:10.1007/s13167-021-00241-6 · Cited by 28 · see citing works
Excretion of Ni, Pb, Cu, As, and Hg in Sweat under Two Sweating Conditions
Kuan, W., Chen, Y., & Liu, C. (2022) · International Journal of Environmental Research and Public Health · doi:10.3390/ijerph19074323 · Cited by 28 · see citing works
Development of Flexible Electronic Biosensors for Healthcare Engineering
Zhao, Y. G., Yan, J., Cheng, J., Fu, Y., Zhou, J., Yan, J., & Guo, J. (2023) · IEEE Sensors Journal · doi:10.1109/jsen.2023.3287291 · Cited by 29 · see citing works
Delshad, M., Sanaei, M., Mohammadi, M. H., Sadeghi, A., & Bashash, D. (2025) · Biomolecules · doi:10.3390/biom15040587 · Cited by 26 · see citing works
Electrochemical sensing of heavy metals in biological media: A review
Gonzalez, K. A., Kazemeini, S., Weber, D. C., Cordero, P. A., Garcia, E. M., & Rusinek, C. A. (2023) · Electroanalysis · doi:10.1002/elan.202300098 · Cited by 26 · see citing works
Soft and transient magnesium plasmonics for environmental and biomedical sensing
Li, R., Xie, S., Zhang, L., Li, L., Kong, D., Wang, Q., Xin, R., Sheng, X., Yin, L., Yu, C., et al. (2018) · Nano Research · doi:10.1007/s12274-018-2028-6 · Cited by 25 · see citing works
Trovato, V., Vitale, A., Bongiovanni, R. M., Ferri, A., Rosace, G., & Plutino, M. R. (2021) · Cellulose · doi:10.1007/s10570-021-03733-w · Cited by 26 · see citing works
Zhang, M., Zhang, S., Wang, Q., Xu, Y., Jiang, L., Yan, Y., Li, J., Tian, Z., & Zhang, W. (2023) · Advanced Materials Technologies · doi:10.1002/admt.202300775 · Cited by 25 · see citing works
Advanced Microfluidic‐Based Wearable Electrochemical Sensors for Continuous Biochemical Monitoring
Park, S., Kim, S., Lee, S.-J., Tsukruk, V. V., Park, S., & Lim, H. (2025) · Advanced Electronic Materials · doi:10.1002/aelm.202500010 · Cited by 27 · see citing works
Passively Addressable Ultra-Low Volume Sweat Chloride Sensor
Ganguly, A., & Prasad, S. (2019) · Sensors · doi:10.3390/s19204590 · Cited by 22 · see citing works
Cannabis Use Surveillance by Sweat Analysis
Gambelunghe, C., Fucci, N., Aroni, K., Bacci, M., Marcelli, A., & Rossi, R. (2016) · Therapeutic Drug Monitoring · doi:10.1097/ftd.0000000000000327 · Cited by 22 · see citing works
Electrowetting valves for sweat-based microfluidics
Naik, A. R., Warren, B., Burns, A., Lenigk, R., Morse, J. D., Alizadeh, A., & Watkins, J. J. (2021) · Microfluidics and Nanofluidics · doi:10.1007/s10404-020-02403-w · Cited by 21 · see citing works
Diagnostic Devices with Microfluidics
(2017) · CRC Press eBooks · doi:10.1201/9781315154442 · Cited by 20 · see citing works
Efficient energy generation from a sweat-powered, wearable, MXene-based hydroelectric nanogenerator
Su, H., Usman, K. A. S., Nilghaz, A., Bu, Y., Tang, K., Dai, L., Liu, D., Razal, J. M., Lei, W., Tian, J., et al. (2024) · Device · doi:10.1016/j.device.2024.100356 · Cited by 20 · see citing works
Hand-Held Volatilome Analyzer Based on Elastically Deformable Nanofibers
Yücel, M., Akın, O., Çayören, M., Akduman, İ., Palaniappan, A., Liedberg, B., Hızal, G., İnci, F., & Yıldız, Ü. H. (2018) · Analytical Chemistry · doi:10.1021/acs.analchem.7b05187 · Cited by 20 · see citing works
- Authors
- Jadoon, S., Karim, S., Akram, M. R., Kalsoom Khan, A., Zia, M. A., Siddiqi, A. R., & Murtaza, G.
- Affiliations
- University of Kurdistan Hewler (IQ)
- University of the Punjab (PK)
- University of Sargodha (PK)
- Department of Chemistry, COMSATS Institute of Information Technology, Abbottabad 22060, Pakistan
- University of Education (PK)
- COMSATS University Islamabad (PK)
- Corresponding author
- Murtaza, Ghulam
- Venue
- International Journal of Analytical Chemistry
- Publisher
- Wiley
- Published
- 2015
- Volume
- 2015
- Pages
- 1-7
- ISSN
- 1687-8760 (ISSN-L)
- 1687-8779
- PMC
- PMC4369929
- OpenAlex
- W2063135415
- Cited by
- 216
- References
- 67
- Citations by year
- 2026: 15 · 2025: 13 · 2024: 14 · 2023: 33 · 2022: 33 · 2021: 33 · 2020: 25 · 2019: 12 · 2018: 16 · 2017: 8 · 2016: 14
- FWCI
- 1.50
- Type
- journal article
- Language
- en
- Open access
- gold
- doi.org
- Locations
- International Journal of Analytical Chemistry (publishedVersion, cc-by)
- Europe PMC (PubMed Central) (publishedVersion, cc-by)
- PubMed Central (publishedVersion, cc-by)
- PubMed (publishedVersion)
- DOAJ (DOAJ: Directory of Open Access Journals) (submittedVersion)
- Topics
- Physical Sciences › Chemistry › Analytical Chemistry › Analytical chemistry methods development
- Physical Sciences › Engineering › Biomedical Engineering › Advanced Chemical Sensor Technologies
- Health Sciences › Medicine › Physiology › Clinical Laboratory Practices and Quality Control
- Keywords
- sweat analysis, sweat collection, ethanol detection, drug detection, ion analysis, metal detection, sweat biomarkers, cystic fibrosis, diabetes mellitus
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review