Quantitative Immuno-Positron Emission Tomography Imaging of HER2-Positive Tumor Xenografts with an Iodine-124 Labeled Anti-HER2 Diabody
The DOI matches its Crossref record; 26 of the 26 references it cites were found in a registry or an index.
Abstract
Positron emission tomography (PET) provides an effective means of both diagnosing/staging several types of cancer and evaluating efficacy of treatment. To date, the only U.S. Food and Drug Administration–approved radiotracer for oncologic PET is 18F-fluoro-deoxyglucose, which measures glucose accumulation as a surrogate for malignant activity. Engineered antibody fragments have been developed with the appropriate targeting specificity and systemic elimination properties predicted to allow for effective imaging of cancer based on expression of tumor associated antigens. We evaluated a small engineered antibody fragment specific for the HER2 receptor tyrosine kinase (C6.5 diabody) for its ability to function as a PET radiotracer when labeled with iodine-124. Our studies revealed HER2-dependent imaging of mouse tumor xenografts with a time-dependent increase in tumor-to-background signal over the course of the experiments. Radioiodination via an indirect method attenuated uptake of radioiodine in tissues that express the Na/I symporter without affecting the ability to image the tumor xenografts. In addition, we validated a method for using a clinical PET/computed tomography scanner to quantify tumor uptake in small-animal model systems; quantitation of the tumor targeting by PET correlated with traditional necropsy-based analysis at all time points analyzed. Thus, diabodies may represent an effective molecular structure for development of novel PET radiotracers.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Sequences of proteins of immunological interest
(1984) · Analytical Biochemistry · doi:10.1016/0003-2697(84)90805-4 · Cited by 3,363
Bolton, A. E., & Hunter, W. M. (1973) · Biochemical Journal · doi:10.1042/bj1330529 · Cited by 3,254
Molecular imaging of cancer with positron emission tomography
Gambhir, S. S. (2002) · Nature Reviews Cancer · doi:10.1038/nrc882 · Cited by 1,656 · cited 1×
“Positron emission tomography (PET) is an imaging modality based on coincidence detection of the two opposing photons that result from annihilation of a positron and an electron (5).”
BackgroundPegram, M. D., Lipton, A., Hayes, D. F., Weber, B. L., Baselga, J. M., Tripathy, D., Baly, D., Baughman, S. A., Twaddell, T., Glaspy, J. A., et al. (1998) · Journal of Clinical Oncology · doi:10.1200/jco.1998.16.8.2659 · Cited by 1,067 · cited 1×
“This is exemplified by the successful use of the HER2-directed antibody, Trastuzumab, in women with HER2 overexpressing breast cancer (37, 38).”
MethodMethods in molecular medicine.
Craig, R. K. (1987) · BMJ · doi:10.1136/bmj.295.6599.646 · Cited by 1,057
(2001) · PubMed · Cited by 943
Schier, R., McCall, A., Adams, G. P., Marshall, K. W., Merritt, H., Yim, M., Crawford, R. S., Weiner, L. M., Marks, C., & Marks, J. D. (1996) · Journal of Molecular Biology · doi:10.1006/jmbi.1996.0598 · Cited by 382 · cited 1×
“33) can be substituted to an alanine residue without affecting affinity of the molecule for HER2 (34).”
BackgroundSelf-citationSlamon, D. J. (1998) · Medical Entomology and Zoology · Cited by 347
Synthesis and evaluation of (18)F-labeled choline analogs as oncologic PET tracers.
DeGrado, T. R., BALDWIN, S. W., Wang, S., Orr, M. D., Liao, R., Friedman, H. S., Reiman, R. E., Price, D. T., & Coleman, R. E. (2001) · PubMed · Cited by 329
Adams, G. P., McCartney, J. E., Tai, M.-S., Oppermann, H., Huston, J. S., Stafford, W. F., Bookman, M. A., Fand, I., Houston, L. L., & Weiner, L. M. (1993) · PubMed · Cited by 248
Self-citation
Cited by
Engineered antibody fragments and the rise of single domains
Holliger, P., & Hudson, P. J. (2005) · Nature Biotechnology · doi:10.1038/nbt1142 · Cited by 1,931
Arming antibodies: prospects and challenges for immunoconjugates
Wu, A. M., & Senter, P. D. (2005) · Nature Biotechnology · doi:10.1038/nbt1141 · Cited by 1,052
Fass, L. (2008) · Molecular Oncology · doi:10.1016/j.molonc.2008.04.001 · Cited by 822
Tumor Imaging Using a Picomolar Affinity HER2 Binding Affibody Molecule
Orlova, A., Magnusson, M., Eriksson, T. L. J., Nilsson, M., Larsson, B., Höidén-Guthenberg, I., Widström, C., Carlsson, J., Tolmachev, V., Ståhl, S., et al. (2006) · Cancer Research · doi:10.1158/0008-5472.can-05-3521 · Cited by 568
Immuno-PET: A Navigator in Monoclonal Antibody Development and Applications
van Dongen, G. A. M. S., Visser, G. W. M., Lub-de Hooge, M. N., de Vries, E. G., & Perk, L. R. (2007) · The Oncologist · doi:10.1634/theoncologist.12-12-1379 · Cited by 330
Preclinical screening of anti‐HER2 nanobodies for molecular imaging of breast cancer
Vaneycken, I., Devoogdt, N., Van Gassen, N., Vincke, C., Xavier, C., Wernery, U., Muyldermans, S., Lahoutte, T., & Caveliers, V. (2011) · The FASEB Journal · doi:10.1096/fj.10-180331 · Cited by 315
64Cu-DOTA-Trastuzumab PET Imaging in Patients with HER2-Positive Breast Cancer
Tamura, K., Kurihara, H., Yonemori, K., Tsuda, H., Suzuki, J., Kono, Y., Honda, N., Kodaira, M., Yamamoto, H., Yunokawa, M., et al. (2013) · Journal of Nuclear Medicine · doi:10.2967/jnumed.112.118612 · Cited by 294
Development of radioimmunotherapeutic and diagnostic antibodies: an inside-out view
Boswell, C. A., & Brechbiel, M. W. (2007) · Nuclear Medicine and Biology · doi:10.1016/j.nucmedbio.2007.04.001 · Cited by 241
Affinity and Avidity in Antibody-Based Tumor Targeting
Rudnick, S. I., & Adams, G. P. (2009) · Cancer Biotherapy and Radiopharmaceuticals · doi:10.1089/cbr.2009.0627 · Cited by 237
Self-citationOlafsen, T., & Wu, A. M. (2010) · Seminars in Nuclear Medicine · doi:10.1053/j.semnuclmed.2009.12.005 · Cited by 223
Radiopharmaceutical chemistry for positron emission tomography
Li, Z., & Conti, P. S. (2010) · Advanced Drug Delivery Reviews · doi:10.1016/j.addr.2010.09.007 · Cited by 212
Bai, J.-W., Qiu, S.-Q., & Zhang, G.-J. (2023) · Signal Transduction and Targeted Therapy · doi:10.1038/s41392-023-01366-y · Cited by 210
“Full-length monoclonal antibodies are usually labeled with long-half-life radionuclides, such as (64)Cu, (89)Zr, (111)In,(235,236) and (124)I.(237) Besides, imaging tracers targeting HER2 by shorter fragments (antibody fragments [Fab or F(ab)2], nanobodies, or affibodies) have been introduced into clinical trials, suc…”
BackgroundAdvances in Immuno–Positron Emission Tomography: Antibodies for Molecular Imaging in Oncology
Knowles, S. M., & Wu, A. M. (2012) · Journal of Clinical Oncology · doi:10.1200/jco.2012.42.4887 · Cited by 209
Orlova, A., Tolmachev, V., Pehrson, R., Lindborg, M., Tran, T., Sandström, M., Nilsson, F. Y., Wennborg, A., Abrahmsén, L., & Feldwisch, J. (2007) · Cancer Research · doi:10.1158/0008-5472.can-06-2887 · Cited by 193
Antibodies and Antimatter: The Resurgence of Immuno-PET
Wu, A. M. (2009) · Journal of Nuclear Medicine · doi:10.2967/jnumed.108.056887 · Cited by 184
“Stabilized iodination protocols (10), or radiometal chelates, are required.”
BackgroundAffibody Molecules for In vivo Characterization of HER2-Positive Tumors by Near-Infrared Imaging
Lee, S. B., Hassan, M., Fisher, R., Chertov, O., Chernomordik, V., Kramer-Marek, G., Gandjbakhche, A., & Capala, J. (2008) · Clinical Cancer Research · doi:10.1158/1078-0432.ccr-07-4076 · Cited by 171
Kramer-Marek, G., Kiesewetter, D. O., Martiniova, L., Jagoda, E., Lee, S. B., & Capala, J. (2008) · European Journal of Nuclear Medicine and Molecular Imaging · doi:10.1007/s00259-007-0658-0 · Cited by 160
“For imaging purposes, this ratio at such a short time post-injection is much better than the previously published data with other HER2-targeting agents that demonstrated much weaker tumor accumulation and worse signal-to-background ratio [ 17 , 31].”
BackgroundMethodResultInfluentialDevelopments and Challenges for mAb-Based Therapeutics
Goswami, S., Wang, W., Arakawa, T., & Ohtake, S. (2013) · Antibodies · doi:10.3390/antib2030452 · Cited by 144
“allow for lower separation of the two binding sites and possess an excellent combination of rapid tumor uptake and clearance for in vivo imaging [276,277].”
Background
Metadata
- Authors
- Robinson, M. K., Doss, M., Shaller, C., Narayanan, D., Marks, J. D., Adler, L. P., González Trotter, D. E., & Adams, G. P.
- Venue
- Cancer Research
- Published
- 2005-02-15
- Volume
- 65
- Issue
- 4
- Pages
- 1471-1478
- ISSN
- 0008-5472 (ISSN-L)
- 1538-7445
- OpenAlex
- W2159581345
- Cited by
- 169
- References
- 26
- FWCI
- 14.76
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.