Irreversible Electroporation Therapy in the Liver: Longitudinal Efficacy Studies in a Rat Model of Hepatocellular Carcinoma
Open accessThe DOI matches its Crossref record; 34 of the 34 references it cites were found in a registry or an index.
Abstract
Irreversible electroporation (IRE) is an innovative local-regional therapy that involves delivery of intense electrical pulses to tissue to induce nanoscale cell membrane defects for tissue ablation. The purpose of this study was to investigate the feasibility of using IRE as a liver-directed ablation technique for the treatment of hepatocellular carcinoma (HCC). In the N1-S1 rodent model, hepatomas were grown in 30 Sprague-Dawley rats that were divided into treatment and control groups. For treatment groups, IRE electrodes were inserted and eight 100-μs 2,500-V pulses were applied to ablate the targeted tumor tissues. For both groups, magnetic resonance imaging scans were performed at baseline and 15-day follow-up intervals to determine tumor sizes (one-dimensional maximum diameter, Dmax; estimated two-dimensional cross-sectional area, Cmax) as a tactic to assess longitudinal outcomes. Additional groups of treated animals were sacrificed at 1-, 3-, and 7-day intervals posttherapy for pathology assessment of treatment response. Magnetic resonance images showed significant tumor size reductions within 15 days posttherapy (32 ± 31% Dmax and 52 ± 39% Cmax decreases compared with 110 ± 35% Dmax and 286 ± 125% Cmax increases for untreated tumors). Pathology correlation studies documented progression from poorly differentiated viable HCC tissues before treatment to extensive tumor necrosis and full regression in 9 of 10 treated rats 7 to 15 days after treatment. Our findings suggest that IRE can be an effective strategy for targeted ablation of liver tumors, prompting its further evaluation for HCC therapy. Cancer Res; 70(4); 1555–63
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Global Cancer Statistics, 2002
Parkin, D. M., Bray, F., Ferlay, J., & Pisani, P. (2005) · CA: A Cancer Journal for Clinicians · doi:10.3322/canjclin.55.2.74 · Cited by 18,196
New Guidelines to Evaluate the Response to Treatment in Solid Tumors
Therasse, P., Arbuck, S. G., Eisenhauer, E. A., Wanders, J., Kaplan, R. S., Rubinstein, L., Verweij, J., Van Glabbeke, M., van Oosterom, A. T., Christian, M. C., et al. (2000) · JNCI: Journal of the National Cancer Institute · doi:10.1093/jnci/92.3.205 · Cited by 15,660
Management of Hepatocellular Carcinoma *
Bruix, J., & Sherman, M. (2005) · Hepatology · doi:10.1002/hep.20933 · Cited by 5,857
Llovet, J. M., Burroughs, A., & Bruix, J. (2003) · The Lancet · doi:10.1016/s0140-6736(03)14964-1 · Cited by 3,608
WHO Handbook for Reporting Results of Cancer Treatment
Palmer, M. K. (1982) · British Journal of Cancer · doi:10.1038/bjc.1982.83 · Cited by 2,198
Tissue Ablation with Irreversible Electroporation
Davalos, R. V., Mir, L. M., & Rubinsky, B. (2005) · Annals of Biomedical Engineering · doi:10.1007/s10439-005-8981-8 · Cited by 1,293 · cited 1×
“Our simulation closely followed those described in previous IRE studies solving the Laplace equation to calculate induced electrical field potentials based on anticipated tissue and electrode conductivities (20, 30).”
MethodLivraghi, T., Giorgio, A., Marin, G., Salmi, A., de Sio, I., Bolondi, L., Pompili, M., Brunello, F., Lazzaroni, S., & Torzilli, G. (1995) · Radiology · doi:10.1148/radiology.197.1.7568806 · Cited by 939 · cited 1×
“However, for HCC between 3 and 5 cm, this rate drops to 50% (13), and the local tumor recurrence rate is up to 17% when treating HCC ≥5 cm (14).”
Lencioni, R., Cioni, D., Crocetti, L., Franchini, C., Pina, C. D., Lera, J., & Bartolozzi, C. (2005) · Radiology · doi:10.1148/radiol.2343040350 · Cited by 867 · cited 1×
“These ablation techniques include percutaneous ethanol injection (6), percutaneous acetic acid injection (7), radiofrequency ablation (8, 9), microwave coagulation therapy (10), laser interstitial thermal ablation (11), and cryoablation therapy (12).”
Novel advancements in the management of hepatocellular carcinoma in 2008
Llovet, J. M., & Bruix, J. (2008) · Journal of Hepatology · doi:10.1016/j.jhep.2008.01.022 · Cited by 815
Irreversible Electroporation: A New Ablation Modality — Clinical Implications
Rubinsky, B., Onik, G., & Mikus, P. (2007) · Technology in Cancer Research & Treatment · doi:10.1177/153303460700600106 · Cited by 781 · cited 1×
“During previous studies, ultrasound imaging methods were used for intraprocedural visualization of IRE ablation procedures (44).”
Percutaneous radiofrequency ablation for hepatocellular carcinoma: An analysis of 1000 cases
Tateishi, R., Shiina, S., Teratani, T., Obi, S., Sato, S., Koike, Y., Fujishima, T., Yoshida, H., Kawabe, T., & Omata, M. (2005) · Cancer · doi:10.1002/cncr.20892 · Cited by 778
In Vivo Results of a New Focal Tissue Ablation Technique: Irreversible Electroporation
Edd, J. F., Horowitz, L., Davalos, R. V., Mir, L. M., & Rubinsky, B. (2006) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2006.873745 · Cited by 510 · cited 1×
“IRE results in a distinct margin between ablated and viable tissues at the position where themagnitude of the electrical field falls below a lethal dose threshold (23).”
Tumor Ablation with Irreversible Electroporation
Al-Sakere, B., André, F., Bernat, C., Connault, E., Opolon, P., Davalos, R. V., Rubinsky, B., & Mir, L. M. (2007) · PLoS ONE · doi:10.1371/journal.pone.0001135 · Cited by 490 · cited 1×
“24), normal liver (25), and prostate tissues (26), as well as cutaneous tumor models (22), have each shown the feasibility of using IRE as a new ablation option with negligible thermal side effects (27).”
Cho, Y. K., Kim, J. K., Kim, M. Y., Rhim, H., & Han, J. K. (2009) · Hepatology · doi:10.1002/hep.22648 · Cited by 466 · cited 1×
“Radiofrequency ablation is the most widely used thermoablation technique providing improved local disease control compared with percutaneous ethanol injection in both small and larger HCC (5, 15).”
Irreversible Electroporation: Implications for Prostate Ablation
Onik, G., Mikus, P., & Rubinsky, B. (2007) · Technology in Cancer Research & Treatment · doi:10.1177/153303460700600405 · Cited by 375 · cited 1×
“Importantly, IRE does not suffer from the heat-sink effect, which is commonly problematic for thermal ablationmethods (21).”
The Effect of Irreversible Electroporation on Blood Vessels
Maor, E., Ivorra, A., Leor, J., & Rubinsky, B. (2007) · Technology in Cancer Research & Treatment · doi:10.1177/153303460700600407 · Cited by 370 · cited 1×
“Additional potential advantages for IRE methods include tumor-specific immunologic reaction (41), little impact on the collagen network within treated tissues, and the potential to abate tumor tissues near large vessels (42).”
Miklavčič, D., Šemrov, D., Mekid, H., & Mir, L. M. (2000) · Biochimica et Biophysica Acta (BBA) - General Subjects · doi:10.1016/s0304-4165(00)00101-x · Cited by 366 · cited 2×
“Before in vivo IRE procedures, we used a commercial finite element modeling (FEM) software package (COMSOL Multi-Physics, version 3.3) to simulate the anticipated ablation zone based on the above-described IRE protocol parameters, electrode spacing, and anticipated lethal electrical field potential for hepatic tissues…”
InfluentialRadiofrequency ablation for hepatocellular carcinoma in so-called high-risk locations
Teratani, T., Yoshida, H., Shiina, S., Obi, S., Sato, S., Tateishi, R., Mine, N., Kondo, Y., Kawabe, T., & Omata, M. (2006) · Hepatology · doi:10.1002/hep.21164 · Cited by 331
Lau, W. Y., & Lai, E. C. H. (2009) · Annals of Surgery · doi:10.1097/sla.0b013e31818eec29 · Cited by 304 · cited 1×
“These ablation techniques include percutaneous ethanol injection (6), percutaneous acetic acid injection (7), radiofrequency ablation (8, 9), microwave coagulation therapy (10), laser interstitial thermal ablation (11), and cryoablation therapy (12).”
Cancer Cells Ablation with Irreversible Electroporation
Miller, L., Leor, J., & Rubinsky, B. (2005) · Technology in Cancer Research & Treatment · doi:10.1177/153303460500400615 · Cited by 298
Vilana, R., Bruix, J., Bru, C., Ayuso, C., Solé, M., & Rodés, J. (1992) · Hepatology · doi:10.1002/hep.1840160212 · Cited by 270 · cited 1×
“However, for HCC between 3 and 5 cm, this rate drops to 50% (13), and the local tumor recurrence rate is up to 17% when treating HCC ≥5 cm (14).”
Lee, E. W., Loh, C. T., & Kee, S. T. (2007) · Technology in Cancer Research & Treatment · doi:10.1177/153303460700600404 · Cited by 241
Mathematical Modeling of Irreversible Electroporation for Treatment Planning
Edd, J. F., & Davalos, R. V. (2007) · Technology in Cancer Research & Treatment · doi:10.1177/153303460700600403 · Cited by 196 · cited 2×
“Our simulation closely followed those described in previous IRE studies solving the Laplace equation to calculate induced electrical field potentials based on anticipated tissue and electrode conductivities (20, 30).”
MethodHistological quantitation of tumour angiogenesis
Fox, S. B., & Harris, A. L. (2004) · Apmis · doi:10.1111/j.1600-0463.2004.apm11207-0803.x · Cited by 160 · cited 1×
“CD34 staining was used as a malignant tumor neovascularization marker (34, 35) to highlight regions of sinusoidal capillarization; caspase-3 staining (previously shown during induction of hepatocyte apoptosis both in vitro and in vivo) was used as a marker of active apoptosis (36, 37).”
Temperature considerations during irreversible electroporation
Davalos, R. V., & Rubinsky, B. (2008) · International Journal of Heat and Mass Transfer · doi:10.1016/j.ijheatmasstransfer.2008.04.046 · Cited by 148 · cited 1×
“24), normal liver (25), and prostate tissues (26), as well as cutaneous tumor models (22), have each shown the feasibility of using IRE as a new ablation option with negligible thermal side effects (27).”
Optimal Parameters for the Destruction of Prostate Cancer Using Irreversible Electroporation
Rubinsky, J., Onik, G. M., Mikus, P., & Rubinsky, B. (2008) · The Journal of Urology · doi:10.1016/j.juro.2008.08.003 · Cited by 144 · cited 1×
“24), normal liver (25), and prostate tissues (26), as well as cutaneous tumor models (22), have each shown the feasibility of using IRE as a new ablation option with negligible thermal side effects (27).”
Varma, M., & Jasani, B. (2005) · Histopathology · doi:10.1111/j.1365-2559.2005.02188.x · Cited by 133
A Study of the Immunological Response to Tumor Ablation with Irreversible Electroporation
Al-Sakere, B., Bernat, C., André, F. M., Connault, E., Opolon, P., Davalos, R. V., & Mir, L. M. (2007) · Technology in Cancer Research & Treatment · doi:10.1177/153303460700600406 · Cited by 126 · cited 1×
“Additional potential advantages for IRE methods include tumor-specific immunologic reaction (41), little impact on the collagen network within treated tissues, and the potential to abate tumor tissues near large vessels (42).”
Locoregional recurrences are frequent after radiofrequency ablation for hepatocellular carcinoma
Harrison, L. E., Koneru, B., Baramipour, P., Fisher, A., Barone, A., Wilson, D. J., Torre, A. D., Cho, K. C., Contractor, D., & Korogodsky, M. (2003) · Journal of the American College of Surgeons · doi:10.1016/s1072-7515(03)00750-6 · Cited by 122
Mass transfer model for drug delivery in tissue cells with reversible electroporation
Granot, Y., & Rubinsky, B. (2008) · International Journal of Heat and Mass Transfer · doi:10.1016/j.ijheatmasstransfer.2008.04.041 · Cited by 115
Hinshaw, J. L., & Lee, F. T. (2007) · Techniques in vascular and interventional radiology · doi:10.1053/j.tvir.2007.08.005 · Cited by 113 · cited 1×
“These ablation techniques include percutaneous ethanol injection (6), percutaneous acetic acid injection (7), radiofrequency ablation (8, 9), microwave coagulation therapy (10), laser interstitial thermal ablation (11), and cryoablation therapy (12).”
Technologies for Ablation of Hepatocellular Carcinoma
Callstrom, M. R., & Charboneau, J. W. (2008) · Gastroenterology · doi:10.1053/j.gastro.2008.05.022 · Cited by 42 · cited 4×
“Cancer Res; 70(4) February 15, 2010 1559”
InfluentialNajimi, M., Smets, F. N., & Sokal, E. M. (2008) · Methods in molecular biology · doi:10.1007/978-1-59745-201-4_6 · Cited by 28 · cited 1×
“CD34 staining was used as a malignant tumor neovascularization marker (34, 35) to highlight regions of sinusoidal capillarization; caspase-3 staining (previously shown during induction of hepatocyte apoptosis both in vitro and in vivo) was used as a marker of active apoptosis (36, 37).”
TSAI, W. ‐., Cheng, J., Lai, K., Lin, C., Lo, G., Hsu, P.-I., YU, H. ‐., Lin, C., Chan, H. ‐., Chen, W., et al. (2008) · Alimentary Pharmacology & Therapeutics · doi:10.1111/j.1365-2036.2008.03702.x · Cited by 28 · cited 1×
“These ablation techniques include percutaneous ethanol injection (6), percutaneous acetic acid injection (7), radiofrequency ablation (8, 9), microwave coagulation therapy (10), laser interstitial thermal ablation (11), and cryoablation therapy (12).”
Cited by
EASL–EORTC Clinical Practice Guidelines: Management of hepatocellular carcinoma
European Association for the Study of the Liver, & European Organisation for Research and Treatment of Cancer (2012) · Journal of Hepatology · doi:10.1016/j.jhep.2011.12.001 · Cited by 5,218
“Irreversible electroporation is currently in clinical evaluation, after pre-clinical positive approach [282].”
BackgroundEASL–EORTC Clinical Practice Guidelines: Management of hepatocellular carcinoma
(2012) · European Journal of Cancer · doi:10.1016/j.ejca.2011.12.021 · Cited by 1,096
Electroporation-Based Technologies for Medicine: Principles, Applications, and Challenges
Yarmush, M. L., Golberg, A., Serša, G., Kotnik, T., & Miklavčič, D. (2014) · Annual Review of Biomedical Engineering · doi:10.1146/annurev-bioeng-071813-104622 · Cited by 889
Cell death due to electroporation – A review
Batista Napotnik, T., Polajžer, T., & Miklavčič, D. (2021) · Bioelectrochemistry · doi:10.1016/j.bioelechem.2021.107871 · Cited by 542
Local-Regional Treatment of Hepatocellular Carcinoma
Lencioni, R., & Crocetti, L. (2012) · Radiology · doi:10.1148/radiol.11110144 · Cited by 514
Metadata
- Authors
- Guo, Y., Zhang, Y., Klein, R., Nijm, G. M., Sahakian, A. V., Omary, R. A., Yang, G.-Y., & Larson, A. C.
- Venue
- Cancer Research
- Published
- 2010-02-14
- Volume
- 70
- Issue
- 4
- Pages
- 1555-1563
- ISSN
- 0008-5472 (ISSN-L)
- 1538-7445
- OpenAlex
- W2002193311
- Cited by
- 182
- References
- 34
- FWCI
- 17.05
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.