CoChat

A Liquid Chromatography-Mass Spectrometry Method for the Simultaneous Measurement of 15 Urinary Estrogens and Estrogen Metabolites: Assay Reproducibility and Interindividual Variability

Open access
Falk, Roni T., Xu, Xia, Keefer, Larry, Veenstra, Timothy D., Ziegler, Regina G. · 2008 · Cancer Epidemiology, Biomarkers & Prevention
Cited by 67

The DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.

Abstract

Background: Accurate, reproducible, and sensitive measurements of endogenous estrogen exposure and individual patterns of estrogen metabolism are needed for etiologic studies of breast cancer. We have developed a high-performance liquid chromatography-tandem mass spectrometry method to quantitate simultaneously 15 urinary estrogens and estrogen metabolites (EM): estrone; estradiol; 3 catechol estrogens; 5 estrogens in the 16α pathway, including estriol; and 5 methoxy estrogens. Methods: Overnight urines were obtained from 45 participants. For the reproducibility study, two blinded, randomized aliquots from 5 follicular and 5 luteal premenopausal women, 5 naturally postmenopausal women, and 5 men were assayed in each of four batches. Assay coefficients of variation and intraclass correlation coefficients were calculated with ANOVA models. Data from the additional 25 participants were added to compare EM levels by menstrual/sex group and assess interindividual variability. Results: For each EM, overall coefficients of variation were ≤10%. Intraclass correlation coefficients for each menstrual/sex group were generally ≥98%. Although geometric mean EM concentrations differed among the four groups, rankings were similar, with estriol, 2-hydroxyestrone, estrone, estradiol, and 16-ketoestradiol accounting for 60% to 75% of total urinary EM. Within each group, interindividual differences in absolute concentrations were consistently high; the range was 10- to 100-fold for nearly all EM. Conclusion: Our high-performance liquid chromatography-tandem mass spectrometry method for measuring 15 urinary EM is highly reproducible, and the range of EM concentrations in each menstrual/sex group is quite large relative to assay variability. Whether these patterns persist in blood and target tissues awaits further development and application of this method. (Cancer Epidemiol Biomarkers Prev 2008;17(12):3411–8)

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1158/1055-9965.epi-08-0355

Cites

3 of 3 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 3 references

Cited by

See all 67

Metadata

Authors
Falk, R. T., Xu, X., Keefer, L., Veenstra, T. D., & Ziegler, R. G.
Venue
Cancer Epidemiology, Biomarkers & Prevention
Published
2008-12-01
Volume
17
Issue
12
Pages
3411-3418
ISSN
  • 1055-9965 (ISSN-L)
  • 1538-7755
OpenAlex
W2154264836
Cited by
67
References
3
FWCI
3.52
Type
journal article
Language
en
Open access
bronze

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: A Liquid Chromatography-Mass Spectrometry Method for the Simultaneous Measurement of 15 Urinary Estrogens and Estrogen Metabolites: Assay Reproducibility and Interindividual Variability. https://app.cochat.ai/papers/10.1158/1055-9965.epi-08-0355
The paper
Falk, R. T., Xu, X., Keefer, L., Veenstra, T. D., & Ziegler, R. G. (2008). A Liquid Chromatography-Mass Spectrometry Method for the Simultaneous Measurement of 15 Urinary Estrogens and Estrogen Metabolites: Assay Reproducibility and Interindividual Variability. Cancer Epidemiology, Biomarkers & Prevention. https://doi.org/10.1158/1055-9965.epi-08-0355

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.