CoChat

The DOI matches its Crossref record; 14 of the 14 references it cites were found in a registry or an index.

Non-Invasive Resting Magnetocardiographic Imaging for the Rapid Detection of Ischemia in Subjects Presenting with Chest Pain

Abstract

BACKGROUND: Early diagnosis of ischemia is complicated by the poor sensitivity of standard tests and contraindication for stress testing in unstable angina patients. Magnetocardiography (MCG) imaging can be used for the rapid, non-invasive detection of ischemia at rest. METHODS: We studied 125 patients with presumed ischemic chest pain. All were chest pain free at the time of scanning. A 6-minute resting MCG scan (CardioMag Imaging, Inc., New York, 9-channel system) was performed. Following the MCG scan, automated software data analysis was performed, and quantitative scores were automatically calculated for each subject. The presence of ischemia was determined after testing with serial troponins, stress testing, and/or coronary angiography. RESULTS: The mean age was 59.4 +/- 13.6 years. Most patients (86.4%) had non-ischemic 12-lead ECG and normal troponin (86.2%). Fifty-five patients (44.0%) were determined to be ischemic. The MCG sensitivity, specificity, positive and negative predictive value was 76.4, 74.3, 70.0 and 80.0%, respectively, for the detection of ischemia (p < 0.0001). CONCLUSIONS: MCG is a new rapid, non-invasive imaging tool able to detect repolarization abnormalities at rest consistent with ischemia in patients presenting with chest pain syndrome and normal or non-specific 12-lead ECG and normal troponin.

Overview

Integrity signals

Registry

Crossref · 10.1159/000093490

Cites

14 of 14 references verified0 citation errors · 0 not checkable

Statistics

Recomputing p-values needs the paper’s full text.

Verification

Claims the paper makes

This paper’s full text isn’t openly available, so its claims and self-check weren’t run. The registry and citation checks still apply.

Citations

Cites

Cited by

See all 78

Metadata

Authors
Tolstrup, K., Madsen, B. E., Ruiz, J. A., Greenwood, S. D., Camacho, J., Siegel, R. J., Gertzen, H. C., Park, J.-W., & Smars, P. A.
Affiliations
  • Cedars-Sinai Medical Center (US)
  • Mayo Clinic (US)
  • Lausitzer Seenland Klinikum (DE)
Venue
Cardiology
Publisher
S. Karger AG
Published
2006
Volume
106
Issue
4
Pages
270-276
ISSN
  • 0008-6312 (ISSN-L)
  • 1421-9751
OpenAlex
W1999463028
Cited by
78
References
14
Citations by year
2026: 2 · 2025: 6 · 2024: 7 · 2023: 4 · 2022: 4 · 2021: 1 · 2020: 2 · 2019: 2 · 2018: 1 · 2017: 4 · 2016: 7 · 2015: 2 · 2014: 5 · 2013: 5 · 2012: 2
FWCI
4.30
Type
journal article
Language
en
Open access
closed
Licence
Locations
  • Cardiology (publishedVersion)
  • PubMed (publishedVersion)
Topics
  • Health Sciences › Medicine › Radiology, Nuclear Medicine and Imaging › Cardiac Imaging and Diagnostics
  • Health Sciences › Medicine › Cardiology and Cardiovascular Medicine › ECG Monitoring and Analysis
  • Health Sciences › Medicine › Cardiology and Cardiovascular Medicine › Acute Myocardial Infarction Research
Keywords
magnetocardiography, myocardial ischemia detection, chest pain, unstable angina, repolarization abnormalities, noninvasive cardiac imaging, diagnostic accuracy, troponin, stress testing
MeSH terms
Adult, Aged, Aged, 80 and over, Angina, Unstable, Chest Pain, Electrocardiography, Female, Humans, Male, Middle Aged, Predictive Value of Tests, Rest, Sensitivity and Specificity, Time Factors, Troponin, Myocardial Ischemia, Magnetocardiography

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.