The DOI matches its Crossref record; 14 of the 14 references it cites were found in a registry or an index.
Non-Invasive Resting Magnetocardiographic Imaging for the Rapid Detection of Ischemia in Subjects Presenting with Chest Pain
Abstract
BACKGROUND: Early diagnosis of ischemia is complicated by the poor sensitivity of standard tests and contraindication for stress testing in unstable angina patients. Magnetocardiography (MCG) imaging can be used for the rapid, non-invasive detection of ischemia at rest. METHODS: We studied 125 patients with presumed ischemic chest pain. All were chest pain free at the time of scanning. A 6-minute resting MCG scan (CardioMag Imaging, Inc., New York, 9-channel system) was performed. Following the MCG scan, automated software data analysis was performed, and quantitative scores were automatically calculated for each subject. The presence of ischemia was determined after testing with serial troponins, stress testing, and/or coronary angiography. RESULTS: The mean age was 59.4 +/- 13.6 years. Most patients (86.4%) had non-ischemic 12-lead ECG and normal troponin (86.2%). Fifty-five patients (44.0%) were determined to be ischemic. The MCG sensitivity, specificity, positive and negative predictive value was 76.4, 74.3, 70.0 and 80.0%, respectively, for the detection of ischemia (p < 0.0001). CONCLUSIONS: MCG is a new rapid, non-invasive imaging tool able to detect repolarization abnormalities at rest consistent with ischemia in patients presenting with chest pain syndrome and normal or non-specific 12-lead ECG and normal troponin.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Citations
Cites
Grundy, S. M., Bilheimer, D. W., Chait, A., Clark, L. T., Denke, M. A., Havel, R. J., Hazzard, W. R., Hulley, S. B., Hunninghake, D. B., Kreisberg, R. A., et al. (1993) · JAMA · doi:10.1001/jama.269.23.3015 · Cited by 27,947
Gibbons, R. J., Abrams, J., Chatterjee, K., Daley, J., Deedwania, P. C., Douglas, J. S., Ferguson, T. B., Fihn, S. D., Fraker, T. D., Gardin, J. M., et al. (2003) · Journal of the American College of Cardiology · doi:10.1016/s0735-1097(02)02848-6 · Cited by 1,689
Magnetocardiograms taken inside a shielded room with a superconducting point-contact magnetometer
Cohen, D., Edelsack, E. A., & Zimmerman, J. E. (1970) · Applied Physics Letters · doi:10.1063/1.1653195 · Cited by 361
Hänninen, H., Takala, P., Mäkijärvi, M., Montonen, J., Korhonen, P., Oikarinen, L., Nenonen, J., Katila, T., & Toivonen, L. (2000) · Annals of Noninvasive Electrocardiology · doi:10.1111/j.1542-474x.2000.tb00380.x · Cited by 74 · cited 1×
“], or on lipid reduction therapy), family history of early coronary artery disease, and history of previous myocardial infarction. Data Interpretation The ECG’s were interpreted by the research teams at the three institutions and categorized into ischemic or non-ischemic according to standard criteria as follows: Isch…”
MethodHänninen, H., Takala, P., Korhonen, P., Oikarinen, L., Mäkijärvi, M., Nenonen, J., Katila, T., & Toivonen, L. (2002) · Annals of Medicine · doi:10.1080/07853890252953518 · Cited by 49 · cited 1×
“], or on lipid reduction therapy), family history of early coronary artery disease, and history of previous myocardial infarction. Data Interpretation The ECG’s were interpreted by the research teams at the three institutions and categorized into ischemic or non-ischemic according to standard criteria as follows: Isch…”
MethodKorhonen, P., MOINTONEN, J., MÄKINÄRVI, M., Katila, T. E., Nieminen, M. S., & Toivonen, L. K. (2000) · Journal of Cardiovascular Electrophysiology · doi:10.1111/j.1540-8167.2000.tb00336.x · Cited by 43
Magnetocardiogram recordings in a nonshielded environment—reproducibility and ischemia detection
Steinberg, B. A., Roguin, A., Watkins, S. P., Hill, P., Fernando, D., & Resar, J. R. (2005) · Annals of Noninvasive Electrocardiology · doi:10.1111/j.1542-474x.2005.05611.x · Cited by 42 · cited 1×
“However, all these studies were performed on early generation MCG machines, which required a magnetically shielded room to obtain images with an acceptable signal-to-noise ratio. In addition, none of those studies utilized an automated software program or standardized method for the analysis of the acquired data. Rece…”
MethodAnalysis of current source of the heart using Isomagnetic and Vector arrow maps.
Nakaya, Y., Sumi, M., Saito, K., Fujino, K., Murakami, M., & Mori, H. (1984) · Japanese Heart Journal · doi:10.1536/ihj.25.701 · Cited by 35
Leeuwen, P. V., Hailer, B., Lange, S., Donker, D. W., & Grönemeyer, D. H. W. (1999) · Biomedizinische Technik/Biomedical Engineering · doi:10.1515/bmte.1999.44.s2.139 · Cited by 26
Comparative capabilities of electrocardiography and magnetocardiography
Plonsey, R. (1972) · The American Journal of Cardiology · doi:10.1016/0002-9149(72)90179-8 · Cited by 24
Cited by
Kwong, J. S. W., Leithäuser, B., Park, J.-W., & Yu, C.-M. (2013) · International Journal of Cardiology · doi:10.1016/j.ijcard.2012.12.056 · Cited by 103
“Tolstrup and colleagues used a different method called effective magnetic dipole vector analysis, an automated analysis of the electrical activity during repolarization, and reported statistically significant differences between the ischemic (n=55) and non-ischemic (n=70) groups [46].”
MethodSelf-citationClinical magnetocardiography: the unshielded bet—past, present, and future
Brisinda, D., Fenici, P., & Fenici, R. (2023) · Frontiers in Cardiovascular Medicine · doi:10.3389/fcvm.2023.1232882 · Cited by 80
Pena, M. E., Pearson, C., Goulet, M. P., Kazan, V. M., DeRita, A. L., Szpunar, S. M., & Dunne, R. (2020) · IJC Heart & Vasculature · doi:10.1016/j.ijcha.2019.100466 · Cited by 78
Identification of ischemic heart disease via machine learning analysis on magnetocardiograms
Tantimongcolwat, T., Naenna, T., Isarankura-Na-Ayudhya, C., Embrechts, M. J., & Prachayasittikul, V. (2008) · Computers in Biology and Medicine · doi:10.1016/j.compbiomed.2008.04.009 · Cited by 57
“Machine learning is a promising technique that explores previously unknown regularities and trends from diverse data sets by learning from sets of data and extrapolating the new-found knowledge on testing data [16–18].”
BackgroundBrala, D., Thevathasan, T., Grahl, S., Barrow, S., Violano, M., Bergs, H., Golpour, A., Suwalski, P., Poller, W., Skurk, C., et al. (2023) · Journal of the American Heart Association · doi:10.1161/jaha.122.027619 · Cited by 54
Optical multichannel room temperature magnetic field imaging system for clinical application
Lembke, G., Erne, S. N., Nowak, H., Menhorn, B., Pasquarelli, A., & Bison, G. (2014) · Biomedical Optics Express · doi:10.1364/boe.5.000876 · Cited by 55
Lim, H. K., Kwon, H., Chung, N., Ko, Y.-G., Kim, J.-M., Kim, I.-S., & Park, Y.-K. (2009) · The American Journal of Cardiology · doi:10.1016/j.amjcard.2008.10.013 · Cited by 52
Magnetocardiography for the detection of myocardial ischemia
Her, A., Dischl, D., Kim, Y. H., Kim, S., & Shin, E. (2023) · Frontiers in Cardiovascular Medicine · doi:10.3389/fcvm.2023.1242215 · Cited by 67
Kwon, H., Kim, K., Lee, Y.-H., Kim, J.-M., Yu, K. K., Chung, N., & Ko, Y.-G. (2010) · Circulation Journal · doi:10.1253/circj.cj-09-0975 · Cited by 47
Can magnetocardiography detect patients with non‐ST‐segment elevation myocardial infarction?
Lim, H. K., Chung, N., Kim, K., Ko, Y., Kwon, H., Lee, Y., Kim, J., Joung, B., Kim, J., Yu, K. K., et al. (2007) · Annals of Medicine · doi:10.1080/07853890701538040 · Cited by 40
A portable diagnostic device for cardiac magnetic field mapping
Mooney, J. W., Ghasemi-Roudsari, S., Banham, E. R., Symonds, C., Pawlowski, N., & Varcoe, B. T. H. (2017) · Biomedical Physics & Engineering Express · doi:10.1088/2057-1976/3/1/015008 · Cited by 39
Shin, E., Lam, Y., Her, A., Brachmann, J., Jung, F., & Park, J. (2016) · International Journal of Cardiology · doi:10.1016/j.ijcard.2016.11.165 · Cited by 39
Alday, E. A. P., Ni, H., Zhang, C., Colman, M. A., Gan, Z., & Zhang, H. (2016) · PLoS ONE · doi:10.1371/journal.pone.0160999 · Cited by 36
Park, J.-W., Shin, E.-S., Ann, S. H., Gödde, M., Park, L. S.-I., Brachmann, J., Vidal-Lopez, S., Wierzbinski, J., Lam, Y.-Y., & Jung, F. (2015) · Clinical Hemorheology and Microcirculation · doi:10.3233/ch-141912 · Cited by 29
Self-citationAgarwal, R. K., Saini, A., Alyousef, T., & Umscheid, C. A. (2012) · Annals of Noninvasive Electrocardiology · doi:10.1111/j.1542-474x.2012.00538.x · Cited by 28
“, 200521 Prospective nonrandomized controlled study Patients with angiographically proven > 50% stenosis of a vessel (19) Patients with angiographically proven nonobstructive CAD (34) Unshielded room”
BackgroundGoernig, M., Liehr, M., Tute, C., Schlosser, M., Haueisen, J., Figulla, H. R., & LEDER, U. (2008) · Annals of Biomedical Engineering · doi:10.1007/s10439-008-9598-5 · Cited by 25
Space‐Time Database for Standardization of Adult Magnetocardiogram‐Making Standard MCG Parameters
Kandori, A., Ogata, K., Watanabe, Y., TAKUMA, N., Tanaka, K. J., Murakami, M., Miyashita, T., Sasaki, N., & Oka, Y. (2008) · Pacing and Clinical Electrophysiology · doi:10.1111/j.1540-8159.2008.01011.x · Cited by 25
Wang, Y., Zhao, Z., Chai, Z., Fang, J., & Chen, M. (2023) · The FASEB Journal · doi:10.1096/fj.202300201rr · Cited by 25
Roth, B. J. (2024) · Biophysics Reviews · doi:10.1063/5.0201950 · Cited by 24
Shin, E.-S., Chung, J.-H., Park, S. G., Saleh, A., Lam, Y.-Y., Bhak, J., Jung, F., Morita, S., & Brachmann, J. (2019) · Clinical Hemorheology and Microcirculation · doi:10.3233/ch-180485 · Cited by 20
Subtraction Magnetocardiogram for Detecting Coronary Heart Disease
Kandori, A., Ogata, K., Miyashita, T., Takaki, H., Kanzaki, H., Hashimoto, S., Shimizu, W., Kamakura, S., Watanabe, S., & Aonuma, K. (2010) · Annals of Noninvasive Electrocardiology · doi:10.1111/j.1542-474x.2010.00392.x · Cited by 20
Wu, Y., Lin, L. C., Tseng, W., Liu, Y., Kao, H.-L., Lin, M. S., Huang, H. C., Wang, S. Y., Horng, H. E., Yang, H. C., et al. (2014) · PubMed · Cited by 22
Yang, S., Feng, L., Zhang, M., Zhang, M., Ma, Z., Zhang, H., Zhang, Y., Liu, L., Zhou, S., Zhao, X., et al. (2024) · BMJ Open · doi:10.1136/bmjopen-2024-086433 · Cited by 21
“23 24 In most studies of MCG detection of myocardial ischaemia, researchers have categorised the analysis of MCG into morphological and quantitative data analyses.”
Wu, Y.-W., Lee, C.-M., Liu, Y.-B., Wang, S.-S., Huang, H.-C., Tseng, W.-K., Jui, H.-Y., Wang, S.-Y., Horng, H.-E., Yang, H.-C., et al. (2013) · Circulation Journal · doi:10.1253/circj.cj-12-1170 · Cited by 18
Sorbo, A. R., Lombardi, G., La Brocca, L., Guida, G., Fenici, R., & Brisinda, D. (2018) · Annals of Noninvasive Electrocardiology · doi:10.1111/anec.12526 · Cited by 18
“Compared to previous studies (Chen et al., 2002, 2004; Steinberg et al., 2004, 2005; Tolstrup et al., 2006), a larger cohort, 204 normal subjects, has been investigated.”
BackgroundMethodResultInfluentialStandard Template of Adult Magnetocardiogram
Kandori, A., Ogata, K., Miyashita, T., Watanabe, Y., Tanaka, K. J., Murakami, M., Oka, Y., Takaki, H., Hashimoto, S., Yamada, Y., et al. (2008) · Annals of Noninvasive Electrocardiology · doi:10.1111/j.1542-474x.2008.00246.x · Cited by 20
Assessing heart disease using a novel magnetocardiography device
Beadle, R., McDonnell, D., Ghasemi-Roudsari, S., Unitt, L., Parker, S. J., & Varcoe, B. T. H. (2021) · Biomedical Physics & Engineering Express · doi:10.1088/2057-1976/abe5c5 · Cited by 18
Her, A., & Park, J. (2016) · Yonsei Medical Journal · doi:10.3349/ymj.2016.57.6.1305 · Cited by 18
Magnetocardiography scoring system to predict the presence of obstructive coronary artery disease
Shin, E., Park, S. G., Saleh, A., Lam, Y., Bhak, J., Jung, F., Morita, S., & Brachmann, J. (2018) · Clinical Hemorheology and Microcirculation · doi:10.3233/ch-189301 · Cited by 16
“Various clinical studies have already shown superior sensitivity of MCG than ECG for ischemic myocardium at rest, as well as under stress (8-12).”
BackgroundGapelyuk, A., Schirdewan, A., Fischer, R., & Wessel, N. (2010) · Physiological Measurement · doi:10.1088/0967-3334/31/10/004 · Cited by 16
Quantification of cardiac magnetic field orientation during ventricular de- and repolarization
Leeuwen, P. V., Hailer, B., Lange, S., Klein, A., Geue, D., Seybold, K., Poplutz, C., & Grönemeyer, D. H. W. (2008) · Physics in Medicine and Biology · doi:10.1088/0031-9155/53/9/006 · Cited by 17
Repolarization Spatial‐Time Current Abnormalities in Patients with Coronary Heart Disease
Ogata, K., Kandori, A., Watanabe, Y., SUZUKI, A., Tanaka, K. J., Oka, Y., Takaki, H., Kanzaki, H., Nakatani, S., Miyatake, K., et al. (2009) · Pacing and Clinical Electrophysiology · doi:10.1111/j.1540-8159.2009.02313.x · Cited by 16
Magnetocardiogram Difference Between Healthy Subjects and Ischemic Heart Disease Patients
Lim, H. K., Chung, N., Ko, Y., Lee, Y., & Park, Y. K. (2009) · IEEE Transactions on Magnetics · doi:10.1109/tmag.2009.2018878 · Cited by 15
“Magnetocardiogram recording using a superconducting quantum interference device (SQUID) sensor, which is the most sensitive sensor to detect magnetism, was introduced over 40 years ago andisknownforitspotentialapplicationinseveralclinicalareas such as angina [ 2 ], myocardiac infarction [3], [4], arrhythmia source det…”
MethodDiagnostic accuracy of the magnetocardiograph for patients with suspected acute coronary syndrome
Goodacre, S., Walters, S. J., Qayyum, H., Coffey, F., Carlton, E., Coats, T., Glazebrook, W., & Unitt, L. (2021) · Emergency Medicine Journal · doi:10.1136/emermed-2020-210396 · Cited by 13
Rat Magnetocardiography Using a Flux-Gate Sensor Based on Iron Garnet Films
Vetoshko, P. M., Gusev, N. A., Chepurnova, D. A., Самойлова, Е. В., Zvezdin, A. K., Korotaeva, A. A., & Belotelov, V. I. (2016) · Biomedical Engineering · doi:10.1007/s10527-016-9628-9 · Cited by 13
Advances of magnetocardiography in application of adult and fetal cardiac diseases
Li, J., Shen, Y., Shen, C., Ning, X., & Xiang, M. (2025) · Frontiers in Cardiovascular Medicine · doi:10.3389/fcvm.2025.1522467 · Cited by 15
Ashokprabhu, N. D., Ziada, K. M., Daher, E., Cho, L., Schmidt, C. W., Alvarez, Y. R., Palmer, C., Kaur, S., Henry, T. D., Pepine, C. J., et al. (2024) · American Heart Journal Plus Cardiology Research and Practice · doi:10.1016/j.ahjo.2024.100424 · Cited by 14
“Several clinical studies have demonstrated that MCG has superior sensitivity compared to ECG and other noninvasive modalities in detecting ischemic myocardium in stable CAD and acute coronary syndrome [22 – 24].”
BackgroundLim, H. K., Chung, N., Kim, K., Ko, Y., Kwon, H., Lee, Y., Kim, J., Cho, J. R., Kim, J., Kim, I.-S., et al. (2006) · Annals of Biomedical Engineering · doi:10.1007/s10439-006-9210-9 · Cited by 12
Two-dimensional propagation of magnetocardiac T wave signals for characterizing myocardial ischemia
Wu, C. C., Huang, H., Liu, Y. B., Lin, L., Lin, L., Chen, M. F., Tsai, M. C., Gao, Y., Yang, S., Horng, H. E., et al. (2008) · Applied Physics Letters · doi:10.1063/1.2913158 · Cited by 9
Tu, C., Yang, S., Wang, Z., Liu, L., Ma, Z., Zhang, H., Feng, L., Cai, B., Zhang, H., Ding, M., et al. (2025) · Physiological Measurement · doi:10.1088/1361-6579/adf0be · Cited by 8
“Compared with ECG, OPM-MCG is more sensitive to tangential currents, which are more prominent in myocardial ischemia, and its 36-channel design significantly improves spatial resolution (Tolstrup et al 2006, Camm et al 2019).”
Comprehensive Analysis and Structural Optimization for Single-Ended Open Magnetic Shielding Cylinder
Yuan, L., Cui, P., Zhang, H., Zhao, F., Li, Y., Zhang, L., Zheng, Y., & Yang, Z. (2024) · IEEE Sensors Journal · doi:10.1109/jsen.2024.3498011 · Cited by 9
Noninvasively diagnosing coronary artery disease with 61-channel MCG data
Chen, T., Zhao, C., Jiang, S., Leeuwen, P. V., & Grönemeyer, D. H. W. (2014) · Chinese Science Bulletin · doi:10.1007/s11434-014-0177-x · Cited by 8
Predictive value of rest magnetocardiography in patients with stable angina
Fenici, R., & Brisinda, D. (2007) · International Congress Series · doi:10.1016/j.ics.2007.02.022 · Cited by 8
Alday, E. A. P., Zhang, C., Colman, M. A., Ni, H., Gan, Z., & Zhang, H. (2015) · Computing in cardiology · doi:10.1109/cic.2015.7410961 · Cited by 8
Bai, M., Huang, Y., Zhang, G., Zheng, W., Lin, Q., & Hu, Z. (2019) · Optics Express · doi:10.1364/oe.27.029534 · Cited by 9
Tolstrup, K., Akhtari, M., Brisinda, D., Meloni, A. M., Siegel, R. J., & Fenici, R. (2024) · American Heart Journal Plus Cardiology Research and Practice · doi:10.1016/j.ahjo.2024.100483 · Cited by 11
Mäkijärvi, M. A., Korhonen, P., Jurkko, R., Väänänen, H., SILTANEN, P., & Hänninen, H. (2010) · Springer eBooks · doi:10.1007/978-1-84882-046-3_44 · Cited by 9
Quan, W., Lu, G.-P., Qi, W.-H., Li, Y., Shen, Y., & Rong, Y. U. A. N. (2008) · Chinese Medical Journal · doi:10.1097/00029330-200801010-00005 · Cited by 7
Yang, S., Yang, K., Zhang, L., Ren, Y., Liu, L., Zhang, H., Feng, L., Ma, Z., Zhou, S., He, Y., et al. (2024) · Cardiovascular Innovations and Applications · doi:10.15212/cvia.2024.0031 · Cited by 7
Brisinda, D., Fenici, R., & Smars, P. (2022) · Contemporary Cardiology · doi:10.1007/978-3-031-05520-1_17 · Cited by 6
Self-citationMagnetoionography enhances diagnostic accuracy of magnetocardiography in coronary artery disease
Dischl, D., Kranz, D. D., Bannasch, S., Gapelyuk, A., Landmesser, U., Park, J.-W., & Wessel, N. (2025) · Scientific Reports · doi:10.1038/s41598-025-14054-4 · Cited by 6
Caiani, G., Chiaramello, E., Ravazzani, P., & Fiocchi, S. (2026) · Bioelectronic Medicine · doi:10.1186/s42234-025-00198-1 · Cited by 7
“Several studies have concluded that MCG is more sensitive to triage of acute chest pain and diagnosis of ischemic heart disease than widely used screening tools such as ECG, echocardiography, and stress tests (Park et al. 2005; Tolstrup et al. 2006; Kwon et al. 2010).”
Magnetocardiography capabilities in myocardium injuries diagnosis
Sosnytskyy, V., Chaikovsky, I. A., Stadnyuk, L., Miasnykov, G., Kazmirchyk, A., Sosnytska, T., & Gurjeva, O. (2013) · World Journal of Cardiovascular Diseases · doi:10.4236/wjcd.2013.35059 · Cited by 6
“During investigations of limitations of the IHD diagnosis at rest, it was determined that MCG exceeds ECG with diagnosis accuracy 60% - 90% for different examined populations [6-10].”
BackgroundDistributed current source reconstruction of magnetocadiography and its accuracy analysis
Wang, W., Chen, Z., Yu-Zhang, L., Zhang, S., Xie, X., & Shi-Qin, J. (2013) · Acta Physica Sinica · doi:10.7498/aps.62.148703 · Cited by 5
The Commercialization of SQUIDs
Fagaly, R. L. (2014) · IEEE Transactions on Applied Superconductivity · doi:10.1109/tasc.2014.2364212 · Cited by 5
“[19] has led to new methodologies for assessing cardiac health [20].”
MethodMagnetocardiac signal analysis based on multiple time windows beamformer method
Wei-Yuan, W., Shi-Qin, J., Da-Fang, Z., Jia-Chen, Z., Yu-Rui, Y., & Wei-wei, Q. (2014) · Acta Physica Sinica · doi:10.7498/aps.63.248702 · Cited by 5
Goernig, M., De Melis, M., Paolo, D. D. P., Tedeschi, W., Liehr, M., Figulla, H. R., & Erne, S. N. (2007) · PubMed · Cited by 7
Special article Magnetocardiography in clinical cardiology. Status quo and future applications
Leithäuser, B., Jung, F., & Park, J. (2011) · Advances in Interventional Cardiology · doi:10.5114/pwki.2011.24739 · Cited by 6
Clinical application of MCG in ischemic heart disease
Hailer, B., & Leeuwen, P. V. (2007) · International Congress Series · doi:10.1016/j.ics.2007.01.045 · Cited by 3
Adult Magnetocardiography: Principles and Clinical Practice
Erasala, V., Senagore, A. J., Shrivastava, P., Malhotra, R., Setegn, E., & Sokolowski, R. (2022) · Springer eBooks · doi:10.1007/978-3-031-05363-4_14 · Cited by 3
Pearson, C. L., Boudreau, B., Kazan, V. M., Pena, M. E., & Takla, R. B. (2022) · Journal of Critical Care & Emergency Medicine · doi:10.47363/jccem/2022(1)103 · Cited by 2
Bioelectric and biomagnetic measurements are differentially sensitive to spiral currents
Haueisen, J., Dietzel, A., Liehr, M., Weiser, T., Elsarnagawy, T., & Bellemann, M. E. (2011) · Biomedizinische Technik/Biomedical Engineering · doi:10.1515/bmt.2011.104 · Cited by 2
Yang, F., & PATTERSON, R. P. (2013) · International Journal of Cardiology · doi:10.1016/j.ijcard.2013.04.073 · Cited by 2
Krause, H., & Dong, H. (2017) · Springer series on chemical sensors and biosensors · doi:10.1007/5346_2017_13 · Cited by 6
“Applications include the detection of myocardial ischemia [21] and viability [22], coronary artery disease [23,24,25], arrhythmogenic risk assessment, imaging of arrhythmogenic sites such as the Wolff-Parkinson-White syndrome [26] or ventricular arrhythmia [27].”
BackgroundQureshi, M. A. (2025) · American Heart Journal Plus Cardiology Research and Practice · doi:10.1016/j.ahjo.2025.100519 · Cited by 2
Chen, J., Ye, C., Sun, L., Xiao, Q., Wang, L., & Niu, Y. (2024) · Academic Conference of China Instrument and Control Society (ACCIS) · doi:10.1109/accis62068.2024.10948626 · Cited by 1
Wearable Wireless Dual-Plane OPM-MCG System for Rest/Stress Cardiac Magnetic Field Measurement
Li, T., Cheng, H., Wang, D., Yin, Y., Li, C., Gu, W., Jiang, C., Lyu, B., & Gao, J. (2025) · IEEE Transactions on Instrumentation and Measurement · doi:10.1109/tim.2025.3595239 · Cited by 2
“Furthermore, various studies have demonstrated MCG’s superior sensitivity in myocardial ischemia detection compared to ECG [10], [11], [12], [13], [14], [15], [16].”
Brisinda, D. (2017) · The Anatolian Journal of Cardiology · doi:10.14744/anatoljcardiol.2017.7556 · Cited by 1
Sun, W., Iwai, M., & KOBAYASHI, K. (2022) · Journal of the Magnetics Society of Japan · doi:10.3379/msjmag.2211r001 · Cited by 2
Wybrane problemy akwizycji i analizy danych diagnostycznych z badań magnetokardiograficznych
Baron-Pałucka, K. (2008) · Elektrotechnika i Elektronika · Cited by 1
Leithäuser, B., Jung, F., & Park, J. W. (2012) · Der Kardiologe · doi:10.1007/s12181-012-0401-3
Chaikovsky, I. A., Stadnyuk, L., Verba, A., Vasetskyi, Y., Будник, М. М., Mjasnikov, G., Kazmirchuk, A., & Lomakovskyi, А. N. (2016) · World Journal of Cardiovascular Diseases · doi:10.4236/wjcd.2016.67026
“There are some approaches for visual sorting of these map which could be provided by physician-expert [2][4].”
BackgroundMethods of Data Obtained With MagnetocardiographyAnalysis
Udovychenko, Y. Y. (2016) · Electronics and Communications · doi:10.20535/2312-1807.2016.21.3.59838
A Portable Diagnostic Device for Cardiac Magnetic Field Mapping
Mooney, J. W., Ghasemi-Roudsari, S., Banham, E. R., Symonds, C., Pawlowski, N., & Varcoe, B. T. H. (2016) · White Rose Research Online (University of Leeds, The University of Sheffield, University of York) · doi:10.48550/arxiv.1609.05771
Mäkijärvi, M. A., Korhonen, P., Jurkko, R., Väänänen, H., SILTANEN, P., & Hänninen, H. (2011) · Springer eBooks · doi:10.1007/978-0-85729-880-5_12
Pena, M. E., Mace, S. E., Bleecker, G., Girard, K. K., Mital, P., Suri, P., & Takla, R. B. (2025) · American Heart Journal Plus Cardiology Research and Practice · doi:10.1016/j.ahjo.2025.100705
Meta-analysis of magnetocardiography in diagnosing coronary artery disease and myocardial ischemia
Li, J., Yan, M., Xiang, M., & Ning, X. (2026) · Next research. · doi:10.1016/j.nexres.2026.101496 · Cited by 1
Metadata
- Authors
- Tolstrup, K., Madsen, B. E., Ruiz, J. A., Greenwood, S. D., Camacho, J., Siegel, R. J., Gertzen, H. C., Park, J.-W., & Smars, P. A.
- Affiliations
- Cedars-Sinai Medical Center (US)
- Mayo Clinic (US)
- Lausitzer Seenland Klinikum (DE)
- Venue
- Cardiology
- Publisher
- S. Karger AG
- Published
- 2006
- Volume
- 106
- Issue
- 4
- Pages
- 270-276
- ISSN
- 0008-6312 (ISSN-L)
- 1421-9751
- OpenAlex
- W1999463028
- Cited by
- 78
- References
- 14
- Citations by year
- 2026: 2 · 2025: 6 · 2024: 7 · 2023: 4 · 2022: 4 · 2021: 1 · 2020: 2 · 2019: 2 · 2018: 1 · 2017: 4 · 2016: 7 · 2015: 2 · 2014: 5 · 2013: 5 · 2012: 2
- FWCI
- 4.30
- Type
- journal article
- Language
- en
- Open access
- closed
- Licence
- www.karger.com/Services/SiteLicenses (vor)
- www.karger.com/Services/SiteLicenses (tdm)
- Locations
- Cardiology (publishedVersion)
- PubMed (publishedVersion)
- Topics
- Health Sciences › Medicine › Radiology, Nuclear Medicine and Imaging › Cardiac Imaging and Diagnostics
- Health Sciences › Medicine › Cardiology and Cardiovascular Medicine › ECG Monitoring and Analysis
- Health Sciences › Medicine › Cardiology and Cardiovascular Medicine › Acute Myocardial Infarction Research
- Keywords
- magnetocardiography, myocardial ischemia detection, chest pain, unstable angina, repolarization abnormalities, noninvasive cardiac imaging, diagnostic accuracy, troponin, stress testing
- MeSH terms
- Adult, Aged, Aged, 80 and over, Angina, Unstable, Chest Pain, Electrocardiography, Female, Humans, Male, Middle Aged, Predictive Value of Tests, Rest, Sensitivity and Specificity, Time Factors, Troponin, Myocardial Ischemia, Magnetocardiography
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.