CoChat

Automatic Pressure Titration with APAP Is as Effective as Manual Titration with CPAP in Patients with Obstructive Sleep Apnea

Fietze, Ingo, Glos, Martin, Moebus, Isabel, Witt, Christian, Penzel, Thomas, Baumann, Gert · 2007 · Respiration
Cited by 45

The DOI matches its Crossref record; 5 of the 5 references it cites were found in a registry or an index.

Abstract

Background: The optimal approach to initiate positive-pressure therapy in patients with obstructive sleep apnea is still debated. Current options are autotitrating positive airway pressure (APAP) or manual titration with continuous positive airway pressure (CPAP). Procedures differ by parameters and by algorithms used for adapting pressure. Objectives: To evaluate the efficacy of attended automatic titration in a randomized crossover study compared with manual titration over 2 nights where the sequence of the titration mode was changed. Therapy outcome was controlled after 6 weeks. Methods: 21 sleep apnea patients were treated using manual CPAP versus automatic APAP titration. The mode used during the 2nd night was continued for 6 weeks. Cardiorespiratory polysomnography, Epworth Sleepiness Scale (ESS), SF-36 score and compliance were assessed. Results: Apnea-hypopnea index reduction was equally effective at similar effective pressure independent of the titration mode. If APAP was applied during the 1st night, total sleep time was longer (384 vs. 331 min, p < 0.01) and sleep efficacy was higher (91 vs. 81%, p < 0.01) than after starting with manual titration with CPAP. Compliance was comparable in both groups (4.6 ± 1.9 h). The ESS improved in both groups (from 12.9 to 6.5). SF-36 scores and therapeutic pressure did not much change. Conclusions: Taking the sequence of titration into account, we found equal effectiveness of CPAP and APAP. Sleep quality was better with initial application of APAP – which favors attended automatic titration if only 1 titration night is possible. Both modes are comparable after 6 weeks regarding therapeutic pressure, efficacy, compliance and quality of life.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1159/000100364

Cites

5 of 5 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 5 references

Research works printed but not linked: 14

  1. 10.1001%2Farchfami.9.2.168 · DOI · Paper page
  2. 10.1183%2F09031936.00.16591400 · DOI · Paper page
  3. 10.1016%2FS1389-9457%2800%2900048-4 · DOI
  4. 10.1378%2Fchest.113.3.714 · DOI
  5. 10.1159%2F000029510 · DOI
  6. 10.1183%2F09031936.04.00133703 · DOI · Paper page
  7. 10.1164%2Frccm.200204-360OC · DOI · Paper page
  8. 10.1136%2Fthx.53.8.643 · DOI · Paper page
  9. 10.1136%2Fthx.54.2.147 · DOI · Paper page
  10. 10.1183%2F09031936.04.00074304 · DOI
  11. 10.1183%2F09031936.96.09091795 · DOI · Paper page
  12. 10.1097%2F00004691-200307000-00009 · DOI
  13. 10.1378%2Fchest.123.3.704 · DOI
  14. 10.1136%2Fthx.52.1.72 · DOI · Paper page

Cited by

Metadata

Authors
Fietze, I., Glos, M., Moebus, I., Witt, C., Penzel, T., & Baumann, G.
Venue
Respiration
Publisher
S. Karger AG
Published
2007
Volume
74
Issue
3
Pages
279-286
ISSN
  • 0025-7931 (ISSN-L)
  • 1423-0356
OpenAlex
W1970824851
Cited by
45
References
5
FWCI
1.78
Type
journal article
Language
en
Open access
closed
Licence

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.