Validation of Ultrasound Techniques Applied to Body Fat Measurement
The DOI matches its Crossref record; 6 of the 6 references it cites were found in a registry or an index.
Abstract
Aims: To evaluate the accuracy of body fat percentage (BF%) estimates from a portable, non-traumatizing ultrasound device with high accuracy and reliability compared to dual-energy X-ray absorptiometry (DEXA), the reference technique. Design: Cross-validation between ultrasound technique (UT), DEXA, air displacement plethysmography (ADP) and bioelectrical impedance (BIA) was developed in the study. Subjects: A total of 89 healthy subjects (41 women, 48 men), aged 48.4 ± 17.7 (mean ± SD), with Body mass index (28.5 ± 7.7 kg/m 2) and body fat DEXA (29.6 ± 10.8 kg) participated. Methods: BF% was measured using an UT associated with anthropometric parameters and simultaneously, with the DEXA reference technique, BIA and ADP. Results: UT estimates of BF% were better correlated with those of DEXA in both males and females (r = 0.98, SEE = 2.0) than with ADP (r = 0.94, SEE = 3.7) or BIA (r = 0.92, SEE = 4.4). The UT in both genders was better (TE = 1.0) than BIA (TE = 2.6) and ADP (TE = 3.0). The 95% limits of agreement were also better for the UT (–2%; 2%) than with BIA (–5.1%; 4.9%) and ADP (–6.3%; 5.3%). Conclusions: The limits of agreement with BIA and ADP are unacceptably high compared to a DEXA measure criterion. The use of a new portable device based on a UT produced a very accurate BF% estimate in relation to the DEXA reference technique.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT
Martin Bland, J., & Altman, D. (1986) · The Lancet · doi:10.1016/s0140-6736(86)90837-8 · Cited by 47,965
Assessment of fat-free mass using bioelectrical impedance measurements of the human body
Lukaski, H., Johnson, P., Bolonchuk, W., & Lykken, G. (1985) · The American Journal of Clinical Nutrition · doi:10.1093/ajcn/41.4.810 · Cited by 1,896
Lean body mass estimation by bioelectrical impedance analysis: a four-site cross-validation study
Segal, K., Van Loan, M., Fitzgerald, P., Hodgdon, A., & Van Itallie, T. (1988) · The American Journal of Clinical Nutrition · doi:10.1093/ajcn/47.1.7 · Cited by 881
A new air displacement method for the determination of human body composition
DEMPSTER, P., & AITKENS, S. (1995) · Medicine & Science in Sports & Exercise · doi:10.1249/00005768-199512000-00017 · Cited by 678
Body-composition assessment via air-displacement plethysmography in adults and children: a review
Fields, D. A., Goran, M. I., & McCrory, M. A. (2002) · The American Journal of Clinical Nutrition · doi:10.1093/ajcn/75.3.453 · Cited by 638
Dual-Energy X-Ray Absorptiometry
Lohman, T. G., & Chen, Z. (2005) · Human Body Composition · doi:10.5040/9781492596950.ch-005 · Cited by 219
Cited by
Ultrasound as a Tool to Assess Body Fat
Wagner, D. R. (2013) · Journal of Obesity · doi:10.1155/2013/280713 · Cited by 252
Ismail, C., Zabal, J., Hernandez, H. J., Woletz, P., Manning, H., Teixeira, C., DiPietro, L., Blackman, M. R., & Harris-Love, M. O. (2015) · Frontiers in Physiology · doi:10.3389/fphys.2015.00302 · Cited by 107
Measuring Muscle Mass and Strength in Obesity: a Review of Various Methods
Sizoo, D., de Heide, L. J. M., Emous, M., van Zutphen, T., Navis, G., & van Beek, A. P. (2021) · Obesity Surgery · doi:10.1007/s11695-020-05082-2 · Cited by 77
Carrillo‐Arango, H. A., Atencio‐Osorio, M. A., López‐Álban, C. A., Nava‐González, E. J., Correa‐Rodríguez, M., Izquierdo, M., & Ramírez‐Vélez, R. (2023) · Physiological Reports · doi:10.14814/phy2.15555 · Cited by 10
Metadata
- Authors
- Pineau, J.-C., Guihard-Costa, A.-M., & Bocquet, M.
- Venue
- Annals of Nutrition and Metabolism
- Publisher
- S. Karger AG
- Published
- 2007
- Volume
- 51
- Issue
- 5
- Pages
- 421-427
- ISSN
- 0250-6807 (ISSN-L)
- 1421-9697
- OpenAlex
- W2093495757
- Cited by
- 79
- References
- 6
- FWCI
- 2.37
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.