Performance of Fluorescence Methods, Radiographic Examination and ICDAS II on Occlusal Surfaces in vitro
Open accessThe DOI matches its Crossref record; 24 of the 24 references it cites were found in a registry or an index.
Abstract
This study compared the performance of fluorescence-based methods, radiographic examination, and International Caries Detection and Assessment System (ICDAS) II on occlusal surfaces. One hundred and nineteen permanent human molars were assessed twice by 2 experienced dentists using the laser fluorescence (LF and LFpen) and fluorescence camera (FC) devices, ICDAS II and bitewing radiographs (BW). After measuring, the teeth were histologically prepared and assessed for caries extension. The sensitivities for dentine caries detection were 0.86 (FC), 0.78 (LFpen), 0.73 (ICDAS II), 0.51 (LF) and 0.34 (BW). The specificities were 0.97 (BW), 0.89 (LF), 0.65 (ICDAS II), 0.63 (FC) and 0.56 (LFpen). BW presented the highest values of likelihood ratio (LR)+ (12.47) and LR– (0.68). Rank correlations with histology were 0.53 (LF), 0.52 (LFpen), 0.41 (FC), 0.59 (ICDAS II) and 0.57 (BW). The area under the ROC curve varied from 0.72 to 0.83. Inter- and intraexaminer intraclass correlation values were respectively 0.90 and 0.85 (LF), 0.93 and 0.87 (LFpen) and 0.85 and 0.76 (FC). The ICDAS II ĸ values were 0.51 (interexaminer) and 0.61 (intraexaminer). The BW ĸ values were 0.50 (interexaminer) and 0.62 (intraexaminer). The Bland and Altman limits of agreement were 46.0 and 38.2 (LF), 55.6 and 40.0 (LFpen) and 1.12 and 0.80 (FC), for intra- and interexaminer reproducibilities. The posttest probability for dentine caries detection was high for BW and LF. In conclusion, LFpen, FC and ICDAS II presented better sensitivity and LF and BW better specificity. ICDAS II combined with BW showed the best performance and is the best combination for detecting caries on occlusal surfaces.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT
Martin Bland, J., & Altman, D. (1986) · The Lancet · doi:10.1016/s0140-6736(86)90837-8 · Cited by 47,965
Statistical Methods for Rates and Proportions
Fleiss, J. L., Levin, B., & Paik, M. C. (2003) · Wiley Series in Probability and Statistics · doi:10.1002/0471445428 · Cited by 18,646
A concordance correlation coefficient to evaluate reproducibility.
Lin, L. I.-K. (1989) · Biometrics · doi:10.2307/2532051 · Cited by 8,785
Hanley, J. A., & McNeil, B. J. (1983) · Radiology · doi:10.1148/radiology.148.3.6878708 · Cited by 7,016 · cited 1×
“A nonparametric statistical test was used to assess the difference among the A z [Hanley and McNeil, 1983].”
MethodClinical Epidemiology: A Basic Science for Clinical Medicine.
(1991) · Annals of Internal Medicine · doi:10.7326/0003-4819-114-9-825_9 · Cited by 3,476
Guidelines for evaluating and expressing the uncertainty of NIST measurement results
Taylor, B. N., & Kuyatt, C. E. (2018) · doi:10.6028/nist.tn.1297-1993 · Cited by 2,582
Ismail, A. I., Sohn, W., Tellez, M., Amaya, A., Sen, A., Hasson, H., & Pitts, N. B. (2007) · Community Dentistry and Oral Epidemiology · doi:10.1111/j.1600-0528.2007.00347.x · Cited by 1,535 · cited 2×
“…of Methods on Occlusal Surfaces Caries Res 2008;42:297–304 299 Visual Examination – ICDAS II Visual examination was performed following the ICDAS II [Ismail et al., 2007; Ekstrand et al., 2007], with direct visualization of the teeth under illumination and coded as: (0) sound tooth surface, (1)…”
BackgroundMethodReceiver Operating Characteristic Curves and Their Use in Radiology
Obuchowski, N. A. (2003) · Radiology · doi:10.1148/radiol.2291010898 · Cited by 843 · cited 1×
“The advantages of the ROC curve are: (a) it includes several cut-off points; (b) it shows the relationship between the sensitivity and specificity, and (c) it is not affected by the prevalence of disease [Obuchowski, 2003].”
BackgroundLussi, A., Imwinkelried, S., Pitts, N. B., Longbottom, C., & Reich, E. (1999) · Caries Research · doi:10.1159/000016527 · Cited by 466 · cited 1×
“Additionally, the changes in lesion morphology could lead to the presence of occlusal dentine caries under a fissure which seems intact to the naked eye [Lussi et al., 1999].”
BackgroundSelf-citationEkstrand, K. R., Ricketts, D. N. J., & Kidd, E. A. M. (1997) · Caries Research · doi:10.1159/000262404 · Cited by 424
A systematic review of the performance of a laser fluorescence device for detecting caries
BADER, J. D., & SHUGARS, D. A. (2004) · The Journal of the American Dental Association · doi:10.14219/jada.archive.2004.0051 · Cited by 332 · cited 1×
“Copyright © 2008 S. Karger AG, Basel The detection of caries is a key element in the prevention and treatment of lesions, and a difficult task in dentistry [Bader and Shugars, 2004].”
BackgroundDetection and Activity Assessment of Primary Coronal Caries Lesions: A Methodologic Study
Ekstrand, K. R., Martignon, S., Ricketts, D. J. N., & Qvist, V. (2007) · Operative Dentistry · doi:10.2341/06-63 · Cited by 315 · cited 3×
“…Surfaces Caries Res 2008;42:297–304 299 Visual Examination – ICDAS II Visual examination was performed following the ICDAS II [Ismail et al., 2007; Ekstrand et al., 2007], with direct visualization of the teeth under illumination and coded as: (0) sound tooth surface, (1) first visual change…”
BackgroundMethodPerformance of a new laser fluorescence device for the detection of occlusal caries in vitro
Lussi, A., & Hellwig, E. (2006) · Journal of Dentistry · doi:10.1016/j.jdent.2005.11.002 · Cited by 159 · cited 3×
“For dentine caries level, the concrete cut-off values were 24 for LF and 17 for LFpen [Lussi and Hellwig, 2006].”
BackgroundMethodSelf-citationSHEEHY, E. C., Brailsford, S. R., Kidd, E. A. M., Beighton, D., & Zoitopoulos, L. (2001) · Caries Research · doi:10.1159/000047485 · Cited by 158 · cited 2×
“A high value of fluorescence may result from other sources than caries, such as the presence of stains, disturbed tooth development or mineralization [Sheehy et al., 2001; Souza-Zaroni et al., 2006].”
BackgroundDetection of Approximal Caries with a New Laser Fluorescence Device
Lussi, A., Hack, A., Hug, I., Heckenberger, H., Megert, B., & Stich, H. (2006) · Caries Research · doi:10.1159/000091054 · Cited by 137 · cited 1×
“Both the first laser fluorescence device (LF) and a more recent pen-type LF device (LFpen) function on the same principle: they emit red light at 655 nm and measure fluorescence of bacterial metabolites in infected dentine [Hibst et al., 2001; Lussi and Hellwig, 2006; Lussi et al., 2006].”
BackgroundSelf-citationRicketts, D. N. J., Ekstrand, K., Kidd, E. A., & Larsen, T. E. (2002) · PubMed · Cited by 99
Mendes, F. M., Hissadomi, M., & Imparato, J. C. P. (2004) · Caries Research · doi:10.1159/000075933 · Cited by 93
Rodrigues, J. A., Diniz, M. B., Josgrilberg, É. B., & Cordeiro, R. D. C. L. (2008) · Lasers in Medical Science · doi:10.1007/s10103-008-0552-4 · Cited by 76
Self-citationde Souza-Zaroni, W. C., Ciccone, J. C., Souza‐Gabriel, A. E., Ramos, R. P., Corona, S. A. M., & Palma‐Dibb, R. G. (2006) · Caries Research · doi:10.1159/000092225 · Cited by 73 · cited 2×
“A high value of fluorescence may result from other sources than caries, such as the presence of stains, disturbed tooth development or mineralization [Sheehy et al., 2001; Souza-Zaroni et al., 2006].”
BackgroundMethodDiniz, M. B., Rodrigues, J. A., de Paula, A. B., & Cordeiro, R. D. C. L. (2008) · Lasers in Medical Science · doi:10.1007/s10103-008-0547-1 · Cited by 60
Self-citationKühnisch, J., Bücher, K., Henschel, V., & Hickel, R. (2007) · European Journal Of Oral Sciences · doi:10.1111/j.1600-0722.2007.00441.x · Cited by 45
The intra/inter-examiner reproducibility of the new DIAGNOdent Pen on occlusal sites
Kühnisch, J., Bücher, K., & Hickel, R. (2007) · Journal of Dentistry · doi:10.1016/j.jdent.2007.02.001 · Cited by 36
Reproducibility of Electrical Caries Measurements: A Technical Problem?
Huysmans, M. C. D. N. J. M., Kühnisch, J., & ten Bosch, J. J. (2005) · Caries Research · doi:10.1159/000086848 · Cited by 14 · cited 2×
“The shape is defined by concentrations of points close to 99 and 0 representing perfect agreement of extreme measurements, and clusters of points at the top and bottom corners of the diamond representing disagreement of extreme measurements [Huysmans et al., 2005].”
BackgroundAssessment criteria for compliance with oral hygiene: application of ROC analysis.
Htoon, H. M., Peng, L. L., & Huak, C. Y. (2007) · Oral health & preventive dentistry · Cited by 13
Cited by
International Caries Detection and Assessment System (ICDAS): A New Concept
Gugnani, N., Pandit, I., Srivastava, N., Gupta, M., & Sharma, M. (2011) · International Journal of Clinical Pediatric Dentistry · doi:10.5005/jp-journals-10005-1089 · Cited by 243
Detection Activity Assessment and Diagnosis of Dental Caries Lesions
Braga, M. M., Mendes, F. M., & Ekstrand, K. R. (2010) · Dental Clinics of North America · doi:10.1016/j.cden.2010.03.006 · Cited by 215
ICDAS II CRITERIA (INTERNATIONAL CARIES DETECTION AND ASSESSMENT SYSTEM)
Dikmen, B. (2015) · European Oral Research · doi:10.17096/jiufd.38691 · Cited by 200
The International Caries Detection and Assessment System – ICDAS: A Systematic Review
Ekstrand, K. R., Gimenez, T., Ferreira, F. R., Mendes, F. M., & Braga, M. M. (2018) · Caries Research · doi:10.1159/000486429 · Cited by 179
Metadata
- Authors
- Rodrigues, J. A., Hug, I., Diniz, M. B., & Lussi, A.
- Venue
- Caries Research
- Publisher
- S. Karger AG
- Published
- 2008
- Volume
- 42
- Issue
- 4
- Pages
- 297-304
- ISSN
- 0008-6568 (ISSN-L)
- 1421-976X
- OpenAlex
- W1966675276
- Cited by
- 233
- References
- 24
- FWCI
- 15.70
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.