Influence of the Test Area on the Mechanical Properties of Skin
The DOI matches its Crossref record.
Abstract
BACKGROUND: New advances in bioengineering have provided commercially available devices for measuring the mechanical properties of skin in vivo. Reproducibility of data and methodological approaches have not yet been thoroughly studied. OBJECTIVE: To study the reproducibility and the influence of the area of the test site on the values of biomechanical variables yielded in a normal population. METHOD: A 500-mbar suction was transmitted to the skin through Cutometer probes equipped with a 2- or 8-mm opening. RESULTS: The best reproducibility was obtained for the maximum distension of skin and for the biological elasticity. The values of the standard biomechanical ratios were almost the same for both probes. Linear correlations were found between parameters of elasticity. CONCLUSION: The Cutometer is a reliable device. A high degree of correlation exists between biomechanical variables related to elasticity. Under a suction of 500 mbar, both the 2- and 8-mm probes give results which correlate statistically in a large population. However, the two probes do not measure precisely the same aspect of skin mechanics. The 2-mm probe measures the capacity of superficial skin folding, and the 8-mm probe explores the biomechanical properties of the dermis itself and of its slipping mobility on the hypodermis. The biomechanical parameters which appear the most clinically relevant for a normal-looking skin are the maximum distension and the biological elasticity.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Advancements in nanofibers for wound dressing: A review
Ambekar, R. S., & Kandasubramanian, B. (2019) · European Polymer Journal · doi:10.1016/j.eurpolymj.2019.05.020 · Cited by 447
A numerical‐experimental method to characterize the non‐linear mechanical behaviour of human skin
Hendriks, F. M., Brokken, D., Van Eemeren, J. T. W. M., Oomens, C. W. J., Baaijens, F. P. T., & Horsten, J. B. A. M. (2003) · Skin Research and Technology · doi:10.1034/j.1600-0846.2003.00019.x · Cited by 347
Hendriks, F. M., Brokken, D., Oomens, C. W. J., Bader, D. L., & Baaijens, F. P. T. (2006) · Medical Engineering & Physics · doi:10.1016/j.medengphy.2005.07.001 · Cited by 338
The influence of solid lipid nanoparticles on skin hydration and viscoelasticity – in vivo study
Wissing, S. A., & Müller, R. H. (2003) · European Journal of Pharmaceutics and Biopharmaceutics · doi:10.1016/s0939-6411(03)00040-7 · Cited by 244
Skin ageing: changes of physical properties of human skin in vivo
Diridollou, S., Vabre, V., Berson, M., Vaillant, L., Black, D., Lagarde, J. M., Grégoire, J. M., Gall, Y., & Patat, F. (2001) · International Journal of Cosmetic Science · doi:10.1046/j.0412-5463.2001.00105.x · Cited by 178
Sex‐ and site‐dependent variations in the thickness and mechanical properties of human skin in vivo
Diridollou, S., Black, D., Lagarde, J. M., Gall, Y., Berson, M., Vabre, V., Patat, F., & Vaillant, L. (2000) · International Journal of Cosmetic Science · doi:10.1111/j.1468-2494.2000.00037.x · Cited by 99
Piérard‐Franchimont, C., Castelli, D., Cromphaut, I. V., Bertin, C., Ries, G., Cauwenbergh, G., & Piérard, G. E. (1998) · Skin Research and Technology · doi:10.1111/j.1600-0846.1998.tb00116.x · Cited by 36
Metadata
- Authors
- Piérard, G. E., Nikkels-Tassoudji, N., & Piérard-Franchimont, C.
- Venue
- Dermatology
- Publisher
- S. Karger AG
- Published
- 1995
- Volume
- 191
- Issue
- 1
- Pages
- 9-15
- ISSN
- 1018-8665 (ISSN-L)
- 1421-9832
- OpenAlex
- W2005589641
- Cited by
- 99
- References
- 0
- FWCI
- 5.20
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.