The DOI matches its Crossref record; 32 of the 32 references it cites were found in a registry or an index.
Cone Beam Computed Tomography in Implant Dentistry: A Systematic Review Focusing on Guidelines, Indications, and Radiation Dose Risks
Abstract
PURPOSE: The aim of the paper is to identify, review, analyze, and summarize available evidence in three areas on the use of cross-sectional imaging, specifically maxillofacial cone beam computed tomography (CBCT) in pre- and postoperative dental implant therapy: (1) Available clinical use guidelines, (2) indications and contraindications for use, and (3) assessment of associated radiation dose risk. MATERIALS AND METHODS: Three focused questions were developed to address the aims. A systematic literature review was performed using a PICO-based search strategy based on MeSH key words specific to each focused question of English-language publications indexed in the MEDLINE database retrospectively from October 31, 2012. These results were supplemented by a hand search and gray literature search. RESULTS: Twelve publications were identified providing guidelines for the use of cross-sectional radiography, particularly CBCT imaging, for the pre- and/or postoperative assessment of potential dental implant sites. The publications discovered by the PICO strategy (43 articles), hand (12), and gray literature searches (1) for the second focus question regarding indications and contraindications for CBCT use in implant dentistry were either cohort or case-controlled studies. For the third question on the assessment of associated radiation dose risk, a total of 22 articles were included. Publication characteristics and themes were summarized in tabular format. CONCLUSIONS: The reported indications for CBCT use in implant dentistry vary from preoperative analysis regarding specific anatomic considerations, site development using grafts, and computer-assisted treatment planning to postoperative evaluation focusing on complications due to damage of neurovascular structures. Effective doses for different CBCT devices exhibit a wide range with the lowest dose being almost 100 times less than the highest dose. Significant dose reduction can be achieved by adjusting operating parameters, including exposure factors and reducing the field of view (FOV) to the actual region of interest.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Preferred reporting items for systematic reviews and meta-analyses: the PRISMA Statement.
(2009) · PubMed Central · Cited by 44,859
Preferred Reporting Items for Systematic Reviews and Meta-Analyses: The PRISMA Statement
Moher, D., Liberati, A., Tetzlaff, J., & Altman, D. G. (2009) · Journal of Clinical Epidemiology · doi:10.1016/j.jclinepi.2009.06.005 · Cited by 19,575
Evidence-Based Medicine: How to Practice and Teach EBM
Sackett, D. L. (2000) · Cited by 5,950
A new volumetric CT machine for dental imaging based on the cone-beam technique: preliminary results
Mozzo, P., Procacci, C., Tacconi, A., Tinazzi Martini, P., & Bergamo Andreis, I. A. (1998) · European Radiology · doi:10.1007/s003300050586 · Cited by 1,383
Epidemiology and etiology of meningioma
Wiemels, J., Wrensch, M., & Claus, E. B. (2010) · Journal of Neuro-Oncology · doi:10.1007/s11060-010-0386-3 · Cited by 1,226
Bulger, R. E. (1992) · Kennedy Institute of Ethics Journal · doi:10.1353/ken.0.0102 · Cited by 992
Guidelines International Network: Toward International Standards for Clinical Practice Guidelines
Qaseem, A., Forland, F., Macbeth, F., Ollenschläger, G., Phillips, S., van der Wees, P., & for the Board of Trustees of the Guidelines International Network* (2012) · Annals of Internal Medicine · doi:10.7326/0003-4819-156-7-201204030-00009 · Cited by 902
Comparative dosimetry of dental CBCT devices and 64-slice CT for oral and maxillofacial radiology
Ludlow, J. B., & Ivanovic, M. (2008) · Oral Surgery, Oral Medicine, Oral Pathology, Oral Radiology, and Endodontology · doi:10.1016/j.tripleo.2008.03.018 · Cited by 872
Dosimetry of 3 CBCT devices for oral and maxillofacial radiology: CB Mercuray, NewTom 3G and i-CAT
Ludlow, J., Davies-Ludlow, L., Brooks, S., & Howerton, W. (2006) · Dentomaxillofacial Radiology · doi:10.1259/dmfr/14340323 · Cited by 851
Effective dose range for dental cone beam computed tomography scanners
Pauwels, R., Beinsberger, J., Collaert, B., Theodorakou, C., Rogers, J., Walker, A., Cockmartin, L., Bosmans, H., Jacobs, R., Bogaerts, R., et al. (2012) · European Journal of Radiology · doi:10.1016/j.ejrad.2010.11.028 · Cited by 642
Self-citationPrinciples of evidence based medicine
Akobeng, A. K. (2005) · Archives of Disease in Childhood · doi:10.1136/adc.2005.071761 · Cited by 413
State-of-the-art on cone beam CT imaging for preoperative planning of implant placement
Guerrero, M. E., Jacobs, R., Loubele, M., Schutyser, F., Suetens, P., & van Steenberghe, D. (2006) · Clinical Oral Investigations · doi:10.1007/s00784-005-0031-2 · Cited by 371
Self-citationZijderveld, S. A., van den Bergh, J. P. A., Schulten, E. A. J. M., & ten Bruggenkate, C. M. (2008) · Journal of Oral and Maxillofacial Surgery · doi:10.1016/j.joms.2008.01.027 · Cited by 252
Clinical indications for digital volume tomography in oral and maxillofacial surgery
Ziegler, C. M., Woertche, R., Brief, J., & Hassfeld, S. (2002) · Dentomaxillofacial Radiology · doi:10.1038/sj.dmfr.4600680 · Cited by 224
Bornstein, M. M., Lauber, R., Sendi, P., & von Arx, T. (2011) · Journal of Endodontics · doi:10.1016/j.joen.2010.11.014 · Cited by 209
Self-citationJanner, S. F. M., Caversaccio, M. D., Dubach, P., Sendi, P., Buser, D., & Bornstein, M. M. (2011) · Clinical Oral Implants Research · doi:10.1111/j.1600-0501.2010.02140.x · Cited by 202
Self-citationBornstein, M. M., Balsiger, R., Sendi, P., & von Arx, T. (2011) · Clinical Oral Implants Research · doi:10.1111/j.1600-0501.2010.02010.x · Cited by 195
Self-citationNackaerts, O., Maes, F., Yan, H., Couto Souza, P., Pauwels, R., & Jacobs, R. (2011) · Clinical Oral Implants Research · doi:10.1111/j.1600-0501.2010.02076.x · Cited by 192
Self-citationDental x‐rays and risk of meningioma
Claus, E. B., Calvocoressi, L., Bondy, M. L., Schildkraut, J. M., Wiemels, J. L., & Wrensch, M. (2012) · Cancer · doi:10.1002/cncr.26625 · Cited by 184
Influence of CBCT exposure conditions on radiation dose
Palomo, J. M., Rao, P. S., & Hans, M. G. (2008) · Oral Surgery Oral Medicine Oral Pathology Oral Radiology and Endodontology · doi:10.1016/j.tripleo.2007.12.019 · Cited by 177
Theodorakou, C., Walker, A., Horner, K., Pauwels, R., Bogaerts, R., Jacobs Dds, R., & The Sedentexct Project Consortium (2012) · The British Journal of Radiology · doi:10.1259/bjr/19389412 · Cited by 173
Hirsch, E., Wolf, U., Heinicke, F., & Silva, M. (2008) · Dentomaxillofacial Radiology · doi:10.1259/dmfr/23424132 · Cited by 161
Profiling of patients presenting with posttraumatic neuropathy of the trigeminal nerve.
Renton, T. F., & Yilmaz, Z. (2011) · PubMed · Cited by 154
Bornstein, M. M., Wölner-Hanssen, A. B., Sendi, P., & von Arx, T. (2009) · Dental Traumatology · doi:10.1111/j.1600-9657.2009.00833.x · Cited by 141
Self-citationEvidence supporting the use of cone-beam computed tomography in orthodontics
van Vlijmen, O. J. C., Kuijpers, M. A. R., Bergé, S. J., Schols, J. G. J. H., Maal, T., Breuning, H., & Kuijpers‐Jagtman, A. M. (2012) · The Journal of the American Dental Association · doi:10.14219/jada.archive.2012.0148 · Cited by 133
Three‐dimensional imaging as a pre‐operative tool in decision making for furcation surgery
Walter, C., Kaner, D., Berndt, D., Weiger, R., & Zitzmann, N. U. (2009) · Journal Of Clinical Periodontology · doi:10.1111/j.1600-051x.2008.01367.x · Cited by 133
Qu, X., Li, G., Ludlow, J. B., et al. (2010) · Oral Surgery Oral Medicine Oral Pathology Oral Radiology and Endodontology · doi:10.1016/j.tripleo.2010.06.013 · Cited by 115
Bornstein, M. M., Wasmer, J., Sendi, P., Janner, S. F. M., Buser, D., & von Arx, T. (2011) · Journal of Endodontics · doi:10.1016/j.joen.2011.09.023 · Cited by 106
Self-citationQuirynen, M., Mraiwa, N., van Steenberghe, D., & Jacobs, R. (2003) · Clinical Oral Implants Research · doi:10.1034/j.1600-0501.2003.140305.x · Cited by 92
Self-citationNunes, L. S. D. S., Bornstein, M. M., Sendi, P., & Buser, D. (2013) · The International Journal of Periodontics & Restorative Dentistry · doi:10.11607/prd.1475 · Cited by 88
Self-citationFamily and personal medical history and risk of meningioma
Claus, E. B., Calvocoressi, L., Bondy, M. L., Schildkraut, J. M., Wiemels, J. L., & Wrensch, M. (2011) · Journal of neurosurgery · doi:10.3171/2011.6.jns11129 · Cited by 85
Janner, S. F. M., Jeger, F. B., Lussi, A., & Bornstein, M. M. (2011) · Journal of Endodontics · doi:10.1016/j.joen.2011.05.005 · Cited by 84
Self-citation
Cited by
Buser, D., Sennerby, L., & De Bruyn, H. (2017) · Periodontology 2000 · doi:10.1111/prd.12185 · Cited by 792
Cone beam computed tomography in implant dentistry: recommendations for clinical use
Jacobs, R., Salmon, B., Codari, M., Hassan, B., & Bornstein, M. M. (2018) · BMC Oral Health · doi:10.1186/s12903-018-0523-5 · Cited by 521
Self-citationBuser, D., Chappuis, V., Belser, U. C., & Chen, S. (2017) · Periodontology 2000 · doi:10.1111/prd.12170 · Cited by 479
Accuracy of four intraoral scanners in oral implantology: a comparative in vitro study
Imburgia, M., Logozzo, S., Hauschild, U., Veronesi, G., Mangano, C., & Mangano, F. G. (2017) · BMC Oral Health · doi:10.1186/s12903-017-0383-4 · Cited by 393
Lim, H., Jeon, S., Cha, J., Lee, J., Choi, S., & Jung, U. (2016) · The Anatomical Record · doi:10.1002/ar.23301 · Cited by 13
Metadata
- Authors
- Bornstein, M., Scarfe, W., Vaughn, V., & Jacobs, R.
- Venue
- The International Journal of Oral & Maxillofacial Implants
- Publisher
- Quintessence Publishing
- Published
- 2014-01
- Volume
- 29
- Issue
- Supplement
- Pages
- 55-77
- ISSN
- 0882-2786 (ISSN-L)
- 1942-4434
- OpenAlex
- W1980709167
- Cited by
- 361
- References
- 32
- FWCI
- 29.41
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.