Unique Morphology and Focal Adhesion Development of Valvular Endothelial Cells in Static and Fluid Flow Environments
The DOI matches its Crossref record; 41 of the 41 references it cites were found in a registry or an index.
Abstract
Background—The influence of mechanical forces on cell function has been well documented for many different cell types. Endothelial cells native to the aortic valve may play an important role in mediating tissue responses to the complex fluid environment, and may therefore respond to fluid flow in a different manner than more characterized vascular endothelial cells. Methods and Results—Porcine endothelial cells of aortic and aortic valvular origin were subjected to 20 dynes/cm 2 steady laminar shear stress for up to 48 hours, with static cultures serving as controls. The aortic valve endothelial cells were observed to align perpendicular to flow, in direct contrast to the aortic endothelial cells, which aligned parallel to flow. Focal adhesion complexes reorganized prominently at the ends of the long axis of aligned cells. Valvular endothelial cell alignment was dependent on Rho-kinase signaling, whereas vascular endothelial cell alignment was dependent on both Rho-kinase and phosphatidylinositol 3-kinase signal pathways. Conclusions—These differences in response to mechanical forces suggest a unique phenotype of valvular endothelial cells not mimicked by vascular endothelial cells, and could have implications for cardiovascular cell biology and cell-source considerations for tissue-engineered valvular substitutes.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
ROCKs: multifunctional kinases in cell behaviour
Riento, K., & Ridley, A. J. (2003) · Nature Reviews Molecular Cell Biology · doi:10.1038/nrm1128 · Cited by 1,941
Functional Arteries Grown in Vitro
Niklason, L. E., Gao, J., Abbott, W. M., Hirschi, K. K., Houser, S., Marini, R., & Langer, R. (1999) · Science · doi:10.1126/science.284.5413.489 · Cited by 1,766
Hammermeister, K., Sethi, G. K., Henderson, W. G., Grover, F. L., Oprian, C., & Rahimtoola, S. H. (2000) · Journal of the American College of Cardiology · doi:10.1016/s0735-1097(00)00834-2 · Cited by 1,144
Regulation of the Cytoskeleton and Cell Adhesion by the Rho Family GTPases in Mammalian Cells
Kaibuchi, K., Kuroda, S., & Amano, M. (1999) · Annual Review of Biochemistry · doi:10.1146/annurev.biochem.68.1.459 · Cited by 1,017
Turbulent fluid shear stress induces vascular endothelial cell turnover in vitro.
Davies, P. F., Remuzzi, A., Gordon, E. J., Dewey, C. F., & Gimbrone, M. A. (1986) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.83.7.2114 · Cited by 847
The Elongation and Orientation of Cultured Endothelial Cells in Response to Shear Stress
Levesque, M. J., & Nerem, R. M. (1985) · Journal of Biomechanical Engineering · doi:10.1115/1.3138567 · Cited by 723
Self-citationFunctional Living Trileaflet Heart Valves Grown In Vitro
Hoerstrup, S. P., Sodian, R., Daebritz, S., Wang, J., Bacha, E. A., Martin, D. P., Moran, A. M., Guleserian, K. J., Sperling, J. S., Kaushal, S., et al. (2000) · Circulation · doi:10.1161/01.cir.102.suppl_3.iii-44 · Cited by 595
Tzima, E. (2001) · The EMBO Journal · doi:10.1093/emboj/20.17.4639 · Cited by 569
Oscillatory Shear Stress Stimulates Adhesion Molecule Expression in Cultured Human Endothelium
Chappell, D. C., Varner, S. E., Nerem, R. M., Medford, R. M., & Alexander, R. W. (1998) · Circulation Research · doi:10.1161/01.res.82.5.532 · Cited by 548
Self-citationWojciak-Stothard, B., & Ridley, A. J. (2003) · The Journal of Cell Biology · doi:10.1083/jcb.200210135 · Cited by 344
Cited by
Chiu, J.-J., & Chien, S. (2011) · Physiological Reviews · doi:10.1152/physrev.00047.2009 · Cited by 2,280
“The exposure of valvular ECs to unidirectional laminar shear stress results in the alignment of these ECs perpendicularly to the direction of flow, in contrast to the parallel alignment of vascular ECs to flow (58, 59).”
ResultHockaday, L. A., Kang, K. H., Colangelo, N. W., Cheung, P. Y. C., Duan, B., Malone, E., Wu, J., Girardi, L. N., Bonassar, L. J., Lipson, H., et al. (2012) · Biofabrication · doi:10.1088/1758-5082/4/3/035005 · Cited by 683
Self-citationThe Emerging Role of Valve Interstitial Cell Phenotypes in Regulating Heart Valve Pathobiology
Liu, A. C., Joag, V. R., & Gotlieb, A. I. (2007) · The American Journal of Pathology · doi:10.2353/ajpath.2007.070251 · Cited by 632
Aikawa, E., Whittaker, P., Farber, M., Mendelson, K., Padera, R. F., Aikawa, M., & Schoen, F. J. (2006) · Circulation · doi:10.1161/circulationaha.105.591768 · Cited by 426
Schoen, F. J. (2008) · Circulation · doi:10.1161/circulationaha.108.805911 · Cited by 421
Heart valve function: a biomechanical perspective
Sacks, M. S., & Yoganathan, A. P. (2007) · Philosophical Transactions of the Royal Society B: Biological Sciences · doi:10.1098/rstb.2007.2122 · Cited by 387
On the biomechanics of heart valve function
Sacks, M. S., David Merryman, W., & Schmidt, D. E. (2009) · Journal of Biomechanics · doi:10.1016/j.jbiomech.2009.05.015 · Cited by 372
Yutzey, K. E., Demer, L. L., Body, S. C., Huggins, G. S., Towler, D. A., Giachelli, C. M., Hofmann-Bowman, M. A., Mortlock, D. P., Rogers, M. B., Sadeghi, M. M., et al. (2014) · Arteriosclerosis, Thrombosis, and Vascular Biology · doi:10.1161/atvbaha.114.302523 · Cited by 371
Heart Valve Tissue Engineering: Concepts, Approaches, Progress, and Challenges
Mendelson, K., & Schoen, F. J. (2006) · Annals of Biomedical Engineering · doi:10.1007/s10439-006-9163-z · Cited by 328
Simmons, C. A., Grant, G. R., Manduchi, E., & Davies, P. F. (2005) · Circulation Research · doi:10.1161/01.res.0000161998.92009.64 · Cited by 274
Engineering cell alignment in vitro
Li, Y., Huang, G., Zhang, X., Wang, L., Du, Y., Lu, T. J., & Xu, F. (2014) · Biotechnology Advances · doi:10.1016/j.biotechadv.2013.11.007 · Cited by 272
Biomechanical factors in the biology of aortic wall and aortic valve diseases
Bäck, M., Gasser, T. C., Michel, J.-B., & Caligiuri, G. (2013) · Cardiovascular Research · doi:10.1093/cvr/cvt040 · Cited by 263
Mahler, G. J., Farrar, E. J., & Butcher, J. T. (2013) · Arteriosclerosis, Thrombosis, and Vascular Biology · doi:10.1161/atvbaha.112.300504 · Cited by 236
Self-citationSucosky, P., Balachandran, K., Elhammali, A., Jo, H., & Yoganathan, A. P. (2009) · Arteriosclerosis, Thrombosis, and Vascular Biology · doi:10.1161/atvbaha.108.176347 · Cited by 235
Insights Into Degenerative Aortic Valve Disease
Goldbarg, S. H., Elmariah, S., Miller, M. A., & Fuster, V. (2007) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2007.06.024 · Cited by 233
Integration of substrate- and flow-derived stresses in endothelial cell mechanobiology
Dessalles, C. A., Leclech, C., Castagnino, A., & Barakat, A. I. (2021) · Communications Biology · doi:10.1038/s42003-021-02285-w · Cited by 230
Butcher, J. T., & Nerem, R. M. (2006) · Tissue Engineering · doi:10.1089/ten.2006.12.905 · Cited by 226
Self-citationMacro- and microscale fluid flow systems for endothelial cell biology
Young, E. W. K., & Simmons, C. A. (2010) · Lab Chip · doi:10.1039/b913390a · Cited by 215
Aortic valve disease and treatment: The need for naturally engineered solutions
Butcher, J. T., Mahler, G. J., & Hockaday, L. A. (2011) · Advanced Drug Delivery Reviews · doi:10.1016/j.addr.2011.01.008 · Cited by 210
Self-citationButcher, J. T., Tressel, S., Johnson, T., Turner, D., Sorescu, G., Jo, H., & Nerem, R. M. (2006) · Arteriosclerosis, Thrombosis, and Vascular Biology · doi:10.1161/01.atv.0000196624.70507.0d · Cited by 191
Self-citationBlood Flow Forces in Shaping the Vascular System: A Focus on Endothelial Cell Behavior
Campinho, P., Vilfan, A., & Vermot, J. (2020) · Frontiers in Physiology · doi:10.3389/fphys.2020.00552 · Cited by 189
Integrating biological vasculature into a multi-organ-chip microsystem
Schimek, K., Busek, M., Brincker, S., Groth, B., Hoffmann, S., Lauster, R., Lindner, G., Lorenz, A., Menzel, U., Sonntag, F., et al. (2013) · Lab on a Chip · doi:10.1039/c3lc50217a · Cited by 180
Butcher, J. T., Norris, R. A., Hoffman, S., Mjaatvedt, C. H., & Markwald, R. R. (2007) · Developmental Biology · doi:10.1016/j.ydbio.2006.09.048 · Cited by 176
Self-citationCyclic strain induces dual-mode endothelial-mesenchymal transformation of the cardiac valve
Balachandran, K., Alford, P. W., Wylie-Sears, J., Goss, J. A., Grosberg, A., Bischoff, J., Aikawa, E., Levine, R. A., & Parker, K. K. (2011) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.1106954108 · Cited by 176
“VECs typically align perpendicular to flow (23, 24), resulting in an anisotropic alignment on the inflow surface that is oriented circumferential to the valve leaflet (23, 25).”
BackgroundHemodynamics and Mechanobiology of Aortic Valve Inflammation and Calcification
Balachandran, K., Sucosky, P., & Yoganathan, A. P. (2011) · International Journal of Inflammation · doi:10.4061/2011/263870 · Cited by 168
“[19] reported that valve endothelial cells aligned parallel to steady, laminar flow in contrast with vascular endothelial cells, underscoring the difference between these two cell types.”
BackgroundResultInfluentialMatrix-dependent adhesion of vascular and valvular endothelial cells in microfluidic channels
Young, E. W. K., Wheeler, A. R., & Simmons, C. A. (2007) · Lab on a Chip · doi:10.1039/b712486d · Cited by 159
Side-Specific Endothelial-Dependent Regulation of Aortic Valve Calcification
Richards, J., El-Hamamsy, I., Chen, S., Sarang, Z., Sarathchandra, P., Yacoub, M. H., Chester, A. H., & Butcher, J. T. (2013) · The American Journal of Pathology · doi:10.1016/j.ajpath.2013.01.037 · Cited by 158
Self-citationLarge animal models of cardiovascular disease
Tsang, H. G., Rashdan, N. A., Whitelaw, C. B. A., Corcoran, B. M., Summers, K. M., & MacRae, V. E. (2016) · Cell Biochemistry and Function · doi:10.1002/cbf.3173 · Cited by 154
Heart Valve Development, Maintenance, and Disease
Tao, G., Kotick, J. D., & Lincoln, J. (2012) · Current Topics in Developmental Biology · doi:10.1016/b978-0-12-387786-4.00006-3 · Cited by 89
Insights into aortic sclerosis and its relationship with coronary artery disease
Milin, A. C., Vorobiof, G., Aksoy, O., & Ardehali, R. (2014) · Journal of the American Heart Association · doi:10.1161/jaha.114.001111 · Cited by 59
“In contrast to vascular endothelial cells, which assemble parallel to the direction of flow, valvular endothelium aligns perpendicular to flow.(22) The difference in arrangement is accompanied by reorganization of focal”
BackgroundCell diversity and plasticity during atrioventricular heart valve EMTs
Lotto, J., Cullum, R., Drissler, S., Arostegui, M., Garside, V. C., Fuglerud, B. M., Clement-Ranney, M., Thakur, A., Underhill, T. M., & Hoodless, P. A. (2023) · Nature Communications · doi:10.1038/s41467-023-41279-6 · Cited by 20
Metadata
- Authors
- Butcher, J. T., Penrod, A. M., García, A. J., & Nerem, R. M.
- Venue
- Arteriosclerosis, Thrombosis, and Vascular Biology
- Published
- 2004-08
- Volume
- 24
- Issue
- 8
- Pages
- 1429-1434
- ISSN
- 1079-5642 (ISSN-L)
- 1524-4636
- OpenAlex
- W2159776277
- Cited by
- 295
- References
- 41
- FWCI
- 5.22
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.