Synergistic Effects of Fluid Shear Stress and Cyclic Circumferential Stretch on Vascular Endothelial Cell Morphology and Cytoskeleton
Open accessThe DOI matches its Crossref record; 25 of the 25 references it cites were found in a registry or an index.
Abstract
The development of atherosclerosis is thought to be initiated by a dysfunctional state of the vascular endothelium. The proposal that mechanical forces play a role in the localization of this disease has led researchers to develop in vitro models to assess their effects on cultured endothelial cells. The arterial endothelium is exposed simultaneously to circumferential hoop stretch and wall shear stress, yet previous investigations have focused on the isolated effects of either cyclic stretch or shear stress. The influence of physiological levels of combined shear stress and hoop stretch on the morphology and F-actin organization of bovine aortic endothelial cells was investigated. Cells subjected for 24 hours to shear stresses higher than 2 dyne/cm 2 or to hoop stretch greater than 2% elongated significantly compared with unstressed controls and oriented along the direction of flow and perpendicular to the direction of stretch. Exposure to more than 4% stretch significantly enhanced the responses to shear stress. Both shear stress and hoop stretch induced formation of stress fibers that were aligned with the cells’ long axes. Simultaneous exposure to both stimuli appeared to enhance stress fiber size and alignment. These results indicate that shear stress and hoop stretch synergistically induce morphological changes in endothelial cells, which suggests that circumferential strain might modulate sensitivity of endothelial cells towards shear stress.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Ku, D. N., Giddens, D. P., Zarins, C. K., & Glagov, S. (1985) · Arteriosclerosis: An Official Journal of the American Heart Association, Inc. · doi:10.1161/01.atv.5.3.293 · Cited by 2,707
Caro, C. G., Fitz-Gerald, J. M., & Schroter, R. C. (1971) · Proceedings of the Royal Society of London. Series B. Biological Sciences · doi:10.1098/rspb.1971.0019 · Cited by 1,357
The Dynamic Response of Vascular Endothelial Cells to Fluid Shear Stress
Dewey, C. F., Bussolari, S. R., Gimbrone, M. A., & Davies, P. F. (1981) · Journal of Biomechanical Engineering · doi:10.1115/1.3138276 · Cited by 1,136
The Elongation and Orientation of Cultured Endothelial Cells in Response to Shear Stress
Levesque, M. J., & Nerem, R. M. (1985) · Journal of Biomechanical Engineering · doi:10.1115/1.3138567 · Cited by 723
Integrins as mechanochemical transducers
Ingber, D. (1991) · Current Opinion in Cell Biology · doi:10.1016/0955-0674(91)90058-7 · Cited by 675
Mechanical stress mechanisms and the cell. An endothelial paradigm.
Davies, P. F., & Tripathi, S. C. (1993) · Circulation Research · doi:10.1161/01.res.72.2.239 · Cited by 629
MOOREJR, J., XU, C., GLAGOV, S., ZARINS, C., & KU, D. (1994) · Atherosclerosis · doi:10.1016/0021-9150(94)90207-0 · Cited by 425
Banes, A. J., Gilbert, J., Taylor, D., & Monbureau, O. (1985) · Journal of Cell Science · doi:10.1242/jcs.75.1.35 · Cited by 404
Increased endothelial cell turnover in areas of in vivo Evans Blue uptake in the pig aorta
Caplan, B. A., & Schwartz, C. J. (1973) · Atherosclerosis · doi:10.1016/0021-9150(73)90031-2 · Cited by 380
Barbee, K. A., Davies, P. F., & Lal, R. (1994) · Circulation Research · doi:10.1161/01.res.74.1.163 · Cited by 350
Davies, P. F., Robotewskyj, A., & Griem, M. L. (1994) · Journal of Clinical Investigation · doi:10.1172/jci117197 · Cited by 325
Vascular Endothelial Morphology as an Indicator of the Pattern of Blood Flow
Nerem, R. M., Levesque, M. J., & Cornhill, J. F. (1981) · Journal of Biomechanical Engineering · doi:10.1115/1.3138275 · Cited by 317
Effects of Pulsatile Flow on Cultured Vascular Endothelial Cell Morphology
Helmlinger, G., Geiger, R. V., Schreck, S., & Nerem, R. M. (1991) · Journal of Biomechanical Engineering · doi:10.1115/1.2891226 · Cited by 288
Tardy, Y., Meister, J. J., Perret, F., Brunner, H. R., & Arditi, M. (1991) · Clinical Physics and Physiological Measurement · doi:10.1088/0143-0815/12/1/003 · Cited by 270
Self-citationMechanical effects on endothelial cell morphology: In vitro assessment
Ives, C. L., Eskin, S. G., & McIntire, L. V. (1986) · In Vitro Cellular & Developmental Biology · doi:10.1007/bf02621134 · Cited by 253
Mechano-chemical control of human endothelium orientation and size.
Shirinsky, V. P., Antonov, A. S., Birukov, K. G., Sobolevsky, A. V., Romanov, Y. A., Kabaeva, N. V., Antonova, G. N., & Smirnov, V. N. (1989) · The Journal of cell biology · doi:10.1083/jcb.109.1.331 · Cited by 229
Molecular aspects of signal transduction of shear stress in the endothelial cell
Malek, A. M., & Izumo, S. (1996) · Molecular Reviews in Cardiovascular Medicine · doi:10.1007/978-94-009-0083-7_21 · Cited by 168
Endothelial cell morphology in focal areas of in vivo Evans Blue uptake in the young pig aorta
Caplan, B. A., Gerrity, R. G., & Schwartz, C. J. (1974) · Experimental and Molecular Pathology · doi:10.1016/0014-4800(74)90082-3 · Cited by 129
Sumpio, B. E., Banes, A. J., Buckley, M., & Johnson, G. (1988) · PubMed · Cited by 129
Moore, J. E., Bürki, E., Suciu, A., Zhao, S., Burnier, M., Brunner, H. R., & Meister, J.-J. (1994) · Annals of Biomedical Engineering · doi:10.1007/bf02368248 · Cited by 110
Self-citationCyclical strain effects on production of vasoactive materials in cultured endothelial cells
Carosi, J. A., Eskin, S. G., & McIntire, L. V. (1992) · Journal of Cellular Physiology · doi:10.1002/jcp.1041510106 · Cited by 105
Sumpio, B. E., Widmann, M. D., Ricotta, J. J., Awolesi, M. A., & WATASE, M. (1994) · Journal of Cellular Physiology · doi:10.1002/jcp.1041580117 · Cited by 90
Hemodynamic Influences on Vascular Endothelial Biology*
Nerem, R. M., & Girard, P. R. (1990) · Toxicologic Pathology · doi:10.1177/019262339001804a07 · Cited by 79
Simple calculation of the velocity profiles for pulsatile flow in a blood vessel using mathematica
He, X., Ku, D. N., & Moore, J. E. (1993) · Annals of Biomedical Engineering · doi:10.1007/bf02368163 · Cited by 62
Self-citationIves, C. L., Eskin, S. G., McIntire, L., & DEBAKEY, M. E. (1983) · PubMed · Cited by 47
Cited by
Mechanotransduction in vascular physiology and atherogenesis
Hahn, C., & Schwartz, M. A. (2009) · Nature Reviews Molecular Cell Biology · doi:10.1038/nrm2596 · Cited by 1,211
Mechanotransduction and endothelial cell homeostasis: the wisdom of the cell
Chien, S. (2007) · American Journal of Physiology-Heart and Circulatory Physiology · doi:10.1152/ajpheart.01047.2006 · Cited by 907
Cell mechanics and mechanotransduction: pathways, probes, and physiology
Huang, H., Kamm, R. D., & Lee, R. T. (2004) · American Journal of Physiology-Cell Physiology · doi:10.1152/ajpcell.00559.2003 · Cited by 548
Small-diameter vascular tissue engineering
Seifu, D. G., Purnama, A., Mequanint, K., & Mantovani, D. (2013) · Nature Reviews Cardiology · doi:10.1038/nrcardio.2013.77 · Cited by 501
Small-Diameter Artificial Arteries Engineered In Vitro
Isenberg, B. C., Williams, C., & Tranquillo, R. T. (2006) · Circulation Research · doi:10.1161/01.res.0000196867.12470.84 · Cited by 469
Metadata
- Authors
- Zhao, S., Suciu, A., Ziegler, T., Moore, J. E., Bürki, E., Meister, J.-J., & Brunner, H. R.
- Venue
- Arteriosclerosis, Thrombosis, and Vascular Biology
- Published
- 1995-10
- Volume
- 15
- Issue
- 10
- Pages
- 1781-1786
- ISSN
- 1079-5642 (ISSN-L)
- 1524-4636
- OpenAlex
- W2059360769
- Cited by
- 211
- References
- 25
- FWCI
- 2.36
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.