CoChat

Cardiovascular Effects of Systemic Nitric Oxide Synthase Inhibition With Asymmetrical Dimethylarginine in Humans

Open access
Kielstein, Jan T., Impraim, Burcu, Simmel, Solveig, Bode-Böger, Stefanie M., Tsikas, Dimitrios, Frölich, Jürgen C., Hoeper, Marius M., Haller, Hermann, Fliser, Danilo · 2004 · Circulation
Cited by 401

The DOI matches its Crossref record; 34 of the 34 references it cites were found in a registry or an index.

Abstract

Background— Increased blood concentrations of the endogenous nitric oxide synthase (NOS) inhibitor asymmetrical dimethylarginine (ADMA) have been linked to excess cardiovascular morbidity and mortality and to progression of renal disease. We evaluated systemic cardiovascular effects of ADMA infusion in healthy subjects using invasive techniques, ie, right heart catheter and inulin/para-aminohippurate clearance. Methods and Results— Plasma ADMA concentrations encountered in patients with cardiovascular diseases, ie, between 2 and 10 μmol/L, caused a significant ( P <0.05) decrease in concentrations of plasma cGMP, the main second messenger of NO. In addition, cardiac output was significantly lower (5.3±0.4 versus 5.8±0.6 L/min; P <0.05 versus baseline), and systemic vascular resistance was significantly higher (1403±123 versus 1221±100 dyn · s · cm −5 ; P <0.05 versus baseline). The infusion of 0.25 mg ADMA · kg −1 · min −1 or 3 μg N G -nitro- l -arginine methyl ester · kg −1 · min −1 , a potent synthetic NOS inhibitor with long action, resulted in a comparable decrease in effective renal plasma flow (from 670±40 to 596±29 mL · min −1 ; P <0.05) and an increase in renovascular resistance (from 79±5 to 90±7 mm Hg · mL −1 · min −1 ; P <0.05). Moreover, administration of ADMA caused significant sodium retention and blood pressure increase (both P <0.05). The observed effects of ADMA in the systemic circulation were sustained corresponding to a mean plasma half-life of 23.5±6.8 minutes, calculated from plasma ADMA decay curves in healthy subjects. Conclusions— Systemic ADMA infusion is responsible for a short-term, modest decrease in cardiac output with comparable decrease in effective renal plasma flow while increasing systemic vascular resistance and blood pressure in a dose-related manner.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1161/01.cir.0000105764.22626.b1

Cites

34 of 34 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Cited by

See all 401

Metadata

Authors
Kielstein, J. T., Impraim, B., Simmel, S., Bode-Böger, S. M., Tsikas, D., Frölich, J. C., Hoeper, M. M., Haller, H., & Fliser, D.
Venue
Circulation
Published
2004-01-20
Volume
109
Issue
2
Pages
172-177
ISSN
  • 0009-7322 (ISSN-L)
  • 1524-4539
OpenAlex
W2037655806
Cited by
401
References
34
FWCI
13.57
Type
journal article
Language
en
Open access
bronze

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.