Cited by 609ECG Monitoring and AnalysisHealthcare Technology and Patient MonitoringCardiac electrophysiology and arrhythmias

The DOI matches its Crossref record; 160 of the 161 references it cites were found in a registry or an index.

Practice Standards for Electrocardiographic Monitoring in Hospital Settings: An American Heart Association Scientific Statement From the Councils on Cardiovascular Nursing, Clinical Cardiology, and Cardiovascular Disease in the Young: Endorsed by the International Society of Computerized Electrocardiology and the American Association of Critical-Care Nurses

Abstract

The goals of electrocardiographic (ECG) monitoring in hospital settings have expanded from simple heart rate and basic rhythm determination to the diagnosis of complex arrhythmias, myocardial ischemia, and prolonged QT interval. Whereas computerized arrhythmia analysis is automatic in cardiac monitoring systems, computerized ST-segment ischemia analysis is available only in newer-generation monitors, and computerized QT-interval monitoring is currently unavailable. Even in hospitals with ST-monitoring capability, ischemia monitoring is vastly underutilized by healthcare professionals. Moreover, because no computerized analysis is available for QT monitoring, healthcare professionals must determine when it is appropriate to manually measure QT intervals (eg, when a patient is started on a potentially proarrhythmic drug). The purpose of the present review is to provide ‘best practices’ for hospital ECG monitoring. Randomized clinical trials in this area are almost nonexistent; therefore, expert opinions are based upon clinical experience and related research in the field of electrocardiography. This consensus document encompasses all areas of hospital cardiac monitoring in both children and adults. The emphasis is on information clinicians need to know to monitor patients safely and effectively. Recommendations are made with regard to indications, timeframes, and strategies to improve the diagnostic accuracy of cardiac arrhythmia, ischemia, and QT-interval monitoring. Currently available ECG lead systems are described, and recommendations related to staffing, training, and methods to improve quality are provided.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1161/01.cir.0000145144.56673.59

Cites

160 of 160 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 161 references

Research works printed but not linked: 22

  1. 1963, Lancet, 83, 53
  2. 10.1161/circ.62.1.7379272 · DOI
  3. 10.1161/circ.79.2.2644056 · DOI
  4. 10.1161/circ.99.7.903 · DOI
  5. Silka MJ. Junctional ectopic tachycardia and perioperative arrhythmias. In: Balaji S Paul C. Gillete PC Case CL eds. Cardiac Arrhythmias After Surgery for Congenital Disease. London England: Arnold Publishers; 2001: 154–164.
  6. 10.1161/circ.92.1.59 · DOI
  7. 1999, Acta Cardiol, 54, 339
  8. 2002, Can J Cardiol, 18, 380
  9. 2001, Ann R Coll Surg Engl, 83, 174
  10. 2003, Eur Heart J, 24, 182
  11. 10.1161/circ.80.3.2527641 · DOI
  12. 10.1161/circ.98.24.2656 · DOI
  13. 1997, Crit Care Nurse, 17, 81
  14. 1994, Primary Cardiol, 20, 23
  15. 1920, Heart, 7, 353
  16. 2002, Circulation, 106, II
  17. 2003, Circulation, 108, IV–362.
  18. 10.1161/circ.13.5.737 · DOI
  19. 1996, Crit Care Nurse, 16, 102
  20. 1991, Heart Lung, 20, 597
  21. 1991, Heart Lung, 20, 27
  22. 1989, Heart Lung, 18, 456

Cited by

Sorted by citations

See all 609

Metadata

Authors
Drew, B. J., Califf, R. M., Funk, M., Kaufman, E. S., Krucoff, M. W., Laks, M. M., Macfarlane, P. W., Sommargren, C., Swiryn, S., & Van Hare, G. F.
Venue
Circulation
Published
2004-10-26
Volume
110
Issue
17
Pages
2721-2746
ISSN
  • 0009-7322 (ISSN-L)
  • 1524-4539
OpenAlex
W2768866949
Cited by
609
References
161
Citations by year
2026: 26 · 2025: 23 · 2024: 20 · 2023: 24 · 2022: 25 · 2021: 30 · 2020: 27 · 2019: 27 · 2018: 25 · 2017: 36 · 2016: 43 · 2015: 45 · 2014: 36 · 2013: 41 · 2012: 23
FWCI
12.66
Type
journal article
Language
en
Open access
closed
Locations
  • Circulation (publishedVersion)
  • PubMed (publishedVersion)
Topics
  • Health Sciences › Medicine › Cardiology and Cardiovascular Medicine › ECG Monitoring and Analysis
  • Health Sciences › Medicine › Surgery › Healthcare Technology and Patient Monitoring
  • Health Sciences › Medicine › Cardiology and Cardiovascular Medicine › Cardiac electrophysiology and arrhythmias
Keywords
ECG monitoring, arrhythmia detection, QT interval monitoring, myocardial ischemia, QT prolongation, computerized ECG analysis, ECG lead systems, quality improvement, proarrhythmic drugs
MeSH terms
Workforce, Arrhythmias, Cardiac, Cardiology, Electrocardiography, Electrodes, Hospitalization, Humans, Long QT Syndrome, Monitoring, Physiologic, Myocardial Ischemia

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review