The DOI matches its Crossref record; 160 of the 161 references it cites were found in a registry or an index.
Practice Standards for Electrocardiographic Monitoring in Hospital Settings: An American Heart Association Scientific Statement From the Councils on Cardiovascular Nursing, Clinical Cardiology, and Cardiovascular Disease in the Young: Endorsed by the International Society of Computerized Electrocardiology and the American Association of Critical-Care Nurses
Abstract
The goals of electrocardiographic (ECG) monitoring in hospital settings have expanded from simple heart rate and basic rhythm determination to the diagnosis of complex arrhythmias, myocardial ischemia, and prolonged QT interval. Whereas computerized arrhythmia analysis is automatic in cardiac monitoring systems, computerized ST-segment ischemia analysis is available only in newer-generation monitors, and computerized QT-interval monitoring is currently unavailable. Even in hospitals with ST-monitoring capability, ischemia monitoring is vastly underutilized by healthcare professionals. Moreover, because no computerized analysis is available for QT monitoring, healthcare professionals must determine when it is appropriate to manually measure QT intervals (eg, when a patient is started on a potentially proarrhythmic drug). The purpose of the present review is to provide ‘best practices’ for hospital ECG monitoring. Randomized clinical trials in this area are almost nonexistent; therefore, expert opinions are based upon clinical experience and related research in the field of electrocardiography. This consensus document encompasses all areas of hospital cardiac monitoring in both children and adults. The emphasis is on information clinicians need to know to monitor patients safely and effectively. Recommendations are made with regard to indications, timeframes, and strategies to improve the diagnostic accuracy of cardiac arrhythmia, ischemia, and QT-interval monitoring. Currently available ECG lead systems are described, and recommendations related to staffing, training, and methods to improve quality are provided.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
The source backs part of the claim, not all of it — or backs it for a different population, condition or comparison.
In the citing paper
“However, the feasibility of continuous human monitoring of multiple screens is questionable and costly, pulling nurses away from direct patient care and education (Drew et al., 2004).”
From 2017 ISHNE-HRS expert consensus statement on ambulatory ECG and external cardiac monitoring/telemetry (2017) · cites this paper as Drew et al., 2004
Experimental — accuracy not yet measured
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Drug-induced prolongation of the QT interval
Roden, D. M. (2004) · New England Journal of Medicine · doi:10.1056/nejmra032426 · Cited by 1,965
Eagle, K. A., Berger, P. B., Calkins, H. G., CHAITMAN, B. R., Ewy, G. A., Fleischmann, K. E., Fleisher, L. A., Froehlich, J. B., Gusberg, R. J., Leppo, J. A., et al. (2002) · Journal of the American College of Cardiology · doi:10.1016/s0735-1097(01)01788-0 · Cited by 1,674
An Accurate, Clinically Practical System For Spatial Vectorcardiography
Frank, E. (1956) · Circulation · doi:10.1161/01.cir.13.5.737 · Cited by 1,097
Hazards of postoperative atrial arrhythmias
Creswell, L. L., Schuessler, R. B., Rosenbloom, M., & Cox, J. L. (1993) · The Annals of Thoracic Surgery · doi:10.1016/0003-4975(93)90894-n · Cited by 995
Mangano, D. T., Browner, W. S., Hollenberg, M., London, M. J., Tubau, J. F., & Tateo, I. M. (1990) · New England Journal of Medicine · doi:10.1056/nejm199012273232601 · Cited by 986
AN ANALYSIS OF THE TIME‐RELATIONS OF ELECTROCARDIOGRAMS.
Bazett, H. C. (1997) · Annals of Noninvasive Electrocardiology · doi:10.1111/j.1542-474x.1997.tb00325.x · Cited by 817
Silent Ischemia as a Marker for Early Unfavorable Outcomes in Patients with Unstable Angina
Gottlieb, S. O., Weisfeldt, M. L., Ouyang, P., Mellits, E. D., & Gerstenblith, G. (1986) · New England Journal of Medicine · doi:10.1056/nejm198605083141903 · Cited by 673
What Clinicians Should Know About the QT Interval
Al‐Khatib, S. M., LaPointe, N. M. A., Kramer, J. M., & Califf, R. M. (2003) · JAMA · doi:10.1001/jama.289.16.2120 · Cited by 671
Self-citationNormal ECG standards for infants and children
Davignon, A., Rautaharju, P. M., Boisselle, E., Soumis, F., Mégélas, M., & Choquette, A. (1980) · Pediatric Cardiology · doi:10.1007/bf02083144 · Cited by 553
Wellens, H. J. J., Bär, F. W. H. M., & Lie, K. I. (1978) · The American Journal of Medicine · doi:10.1016/0002-9343(78)90176-6 · Cited by 538
Research works printed but not linked: 22
- 1963, Lancet, 83, 53
- 10.1161/circ.62.1.7379272 · DOI
- 10.1161/circ.79.2.2644056 · DOI
- 10.1161/circ.99.7.903 · DOI
- Silka MJ. Junctional ectopic tachycardia and perioperative arrhythmias. In: Balaji S Paul C. Gillete PC Case CL eds. Cardiac Arrhythmias After Surgery for Congenital Disease. London England: Arnold Publishers; 2001: 154–164.
- 10.1161/circ.92.1.59 · DOI
- 1999, Acta Cardiol, 54, 339
- 2002, Can J Cardiol, 18, 380
- 2001, Ann R Coll Surg Engl, 83, 174
- 2003, Eur Heart J, 24, 182
- 10.1161/circ.80.3.2527641 · DOI
- 10.1161/circ.98.24.2656 · DOI
- 1997, Crit Care Nurse, 17, 81
- 1994, Primary Cardiol, 20, 23
- 1920, Heart, 7, 353
- 2002, Circulation, 106, II
- 2003, Circulation, 108, IV–362.
- 10.1161/circ.13.5.737 · DOI
- 1996, Crit Care Nurse, 16, 102
- 1991, Heart Lung, 20, 597
- 1991, Heart Lung, 20, 27
- 1989, Heart Lung, 18, 456
Cited by
Sorted by citations
Roffi, M., Patrono, C., Collet, J.-P., Mueller, C., Valgimigli, M., Andreotti, F., Bax, J. J., Borger, M. A., Brotons, C., Chew, D. P., et al. (2016) · European Heart Journal · doi:10.1093/eurheartj/ehv320 · Cited by 8,261
The Internet of Things for Health Care: A Comprehensive Survey
Islam, S. M. R., Kwak, D., Kabir, M. H., Hossain, M., & Kwak, K.-S. (2015) · IEEE Access · doi:10.1109/access.2015.2437951 · Cited by 3,199
Mitchell, C., Rahko, P. S., Blauwet, L. A., Canaday, B., Finstuen, J. A., Foster, M., Horton, K. D., Ogunyankin, K. O., Palma, R. A., & Velazquez, E. J. (2018) · Journal of the American Society of Echocardiography · doi:10.1016/j.echo.2018.06.004 · Cited by 2,628
Trung, T. Q., & Lee, N. (2016) · Advanced Materials · doi:10.1002/adma.201504244 · Cited by 2,160
Drew, B. J., Ackerman, M. J., Funk, M., Gibler, W. B., Kligfield, P., Menon, V., Philippides, G. J., Roden, D. M., & Zareba, W. (2010) · Circulation · doi:10.1161/circulationaha.109.192704 · Cited by 821
Self-citation2011 ACCF/AHA Guideline for Coronary Artery Bypass Graft Surgery
Hillis, L. D., Smith, P. K., Anderson, J. L., Bittl, J. A., Bridges, C. R., Byrne, J. G., Cigarroa, J. E., DiSesa, V. J., Hiratzka, L. F., Hutter, A. M., et al. (2011) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2011.08.009 · Cited by 826
Recommendations for the Standardization and Interpretation of the Electrocardiogram
Kligfield, P., Gettes, L. S., Bailey, J. J., Childers, R., Deal, B. J., Hancock, E. W., van Herpen, G., Kors, J. A., Macfarlane, P. W., Mirvis, D. M., et al. (2007) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2007.01.024 · Cited by 815
Self-citationKligfield (2007) · doi:10.1161/circulationaha.106.180200 · Cited by 802
Self-citation2011 ACCF/AHA Guideline for Coronary Artery Bypass Graft Surgery
Hillis, L. D., Smith, P. K., Anderson, J. L., Bittl, J. A., Bridges, C. R., Byrne, J. G., Cigarroa, J. E., DiSesa, V. J., Hiratzka, L. F., Hutter, A. M., et al. (2011) · Circulation · doi:10.1161/cir.0b013e31823c074e · Cited by 795
Wearable Chemical Sensors: Present Challenges and Future Prospects
Bandodkar, A. J., Jeerapan, I., & Wang, J. (2016) · ACS Sensors · doi:10.1021/acssensors.6b00250 · Cited by 778
2011 ACCF/AHA Guideline for Coronary Artery Bypass Graft Surgery: Executive Summary
Hillis, L. D., Smith, P. K., Anderson, J. L., Bittl, J. A., Bridges, C. R., Byrne, J. G., Cigarroa, J. E., DiSesa, V. J., Hiratzka, L. F., Hutter, A. M., et al. (2011) · Circulation · doi:10.1161/cir.0b013e31823b5fee · Cited by 617
Mapping and Ablation of Ventricular Fibrillation Associated With Long-QT and Brugada Syndromes
Haı̈ssaguerre, M., Extramiana, F., Hocini, M., CAUCHEMEZ, B., Jaı̈s, P., Cabrera, J. Á., Farre, G., Leenhardt, A., Sanders, P., Scavée, C., et al. (2003) · Circulation · doi:10.1161/01.cir.0000088781.99943.95 · Cited by 518
Monitor Alarm Fatigue: Standardizing Use of Physiological Monitors and Decreasing Nuisance Alarms
Graham, K. C., & Cvach, M. M. (2010) · American Journal of Critical Care · doi:10.4037/ajcc2010651 · Cited by 460
Flexible Wearable Sensors for Cardiovascular Health Monitoring
Chen, S., Qi, J., Fan, S., Qiao, Z., Yeo, J. C., & Lim, C. T. (2021) · Advanced Healthcare Materials · doi:10.1002/adhm.202100116 · Cited by 453
IoT-Based Applications in Healthcare Devices
Pradhan, B. K., Bhattacharyya, S., & Pal, K. (2021) · Journal of Healthcare Engineering · doi:10.1155/2021/6632599 · Cited by 481
Internet of Things: A survey of enabling technologies in healthcare and its applications
Dhanvijay, M. M., & Patil, S. (2019) · Computer Networks · doi:10.1016/j.comnet.2019.03.006 · Cited by 388
Prevention of Torsade de Pointes in Hospital Settings
Drew, B. J., Ackerman, M. J., Funk, M., Gibler, W. B., Kligfield, P., Menon, V., Philippides, G. J., Roden, D. M., & Zaręba, W. (2010) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2010.01.001 · Cited by 371
Self-citationECG Monitoring Systems: Review, Architecture, Processes, and Key Challenges
Serhani, M. A., Kassabi, H. T. E., Ismail, H., & Navaz, A. N. (2020) · Sensors · doi:10.3390/s20061796 · Cited by 373
Sandau, K. E., Funk, M., Auerbach, A. D., Barsness, G. W., Blum, K., Cvach, M. M., Lampert, R., May, J. L., McDaniel, G. M., Perez, M. V., et al. (2017) · Circulation · doi:10.1161/cir.0000000000000527 · Cited by 370
Self-citationSendelbach, S. E., & Funk, M. (2013) · AACN Advanced Critical Care · doi:10.1097/nci.0b013e3182a903f9 · Cited by 497
Self-citationNon-contact heart rate and heart rate variability measurements: A review
Kranjec, J., Beguš, S., Geršak, G., & Drnovšek, J. (2014) · Biomedical Signal Processing and Control · doi:10.1016/j.bspc.2014.03.004 · Cited by 332
Drug-induced QT interval prolongation: mechanisms and clinical management
Nachimuthu, S., Assar, M. D., & SCHUSSLER, J. M. (2012) · Therapeutic Advances in Drug Safety · doi:10.1177/2042098612454283 · Cited by 325
Steinberg, J. S., Varma, N., Cygankiewicz, I., Aziz, P., Balsam, P., Baranchuk, A., Cantillon, D. J., Dilaveris, P., Dubner, S. J., El-Sherif, N., et al. (2017) · Heart Rhythm · doi:10.1016/j.hrthm.2017.03.038 · Cited by 303
Morrison, L. J., Neumar, R. W., Zimmerman, J. L., Link, M. S., Newby, L. K., McMullan, P. W., Hoek, T. L. V., Halverson, C. C., Doering, L. V., Peberdy, M. A., et al. (2013) · Circulation · doi:10.1161/cir.0b013e31828b2770 · Cited by 311
Sendelbach, S., & Funk, M. (2013) · AACN Advanced Critical Care · doi:10.4037/nci.0b013e3182a903f9 · Cited by 497
Self-citation2011 ACCF/AHA guideline for coronary artery bypass graft surgery: Executive summary
Hillis, L. D., Smith, P. K., Anderson, J. L., Bittl, J. A., Bridges, C. R., Byrne, J. G., Cigarroa, J. E., DiSesa, V. J., Hiratzka, L. F., Hutter, A. M., et al. (2011) · Journal of Thoracic and Cardiovascular Surgery · doi:10.1016/j.jtcvs.2011.10.015 · Cited by 251
Krishnamoorthy, S., Dua, A., & Gupta, S. R. (2021) · Journal of Ambient Intelligence and Humanized Computing · doi:10.1007/s12652-021-03302-w · Cited by 250
Soft Thermal Sensor with Mechanical Adaptability
Yang, H., Qi, D., Liu, Z., Chandran, B. K., Wang, T., Yu, J., & Chen, X. (2016) · Advanced Materials · doi:10.1002/adma.201602994 · Cited by 227
Cardiopulmonary Resuscitation in Infants and Children With Cardiac Disease
Marino, B. S., Tabbutt, S., MacLaren, G., Hazinski, M. F., Adatia, I., Atkins, D. L., Checchia, P. A., DeCaen, A., Fink, E. L., Hoffman, G. M., et al. (2018) · Circulation · doi:10.1161/cir.0000000000000524 · Cited by 206
Effective hemodynamic monitoring
Pinsky, M. R., Cecconi, M., Chew, M. S., De Backer, D., Douglas, I., Edwards, M., Hamzaoui, O., Hernandez, G., Martin, G., Monnet, X., et al. (2022) · Critical Care · doi:10.1186/s13054-022-04173-z · Cited by 167
“Turn it Off!”: Diabetes Device Alarm Fatigue Considerations for the Present and the Future
Shivers, J. P., Mackowiak, L., Anhalt, H., & Zisser, H. (2013) · Journal of Diabetes Science and Technology · doi:10.1177/193229681300700324 · Cited by 159
Multi-Resident Non-Contact Vital Sign Monitoring Using Radar: A Review
Singh, A., Rehman, S. U., Yongchareon, S., & Chong, P. H. J. (2020) · IEEE Sensors Journal · doi:10.1109/jsen.2020.3036039 · Cited by 157
Kim, Y., Mahmood, M., Lee, Y.-K., Kim, N. K., Kwon, S., Herbert, R., Kim, D., Cho, H. C., & Yeo, W. (2019) · Advanced Science · doi:10.1002/advs.201900939 · Cited by 158
Heffernan, K. S., Fahs, C. A., Shinsako, K. K., Jae, S. Y., & Fernhall, B. (2007) · American Journal of Physiology-Heart and Circulatory Physiology · doi:10.1152/ajpheart.00648.2007 · Cited by 153
Roffi, M., Patrono, C., Collet, J., Mueller, C. E., Valgimigli, M., Andreotti, F., Bax, J. J., Borger, M. A., Brotons, C., Chew, D. P., et al. (2015) · Revista Española de Cardiología (English Edition) · doi:10.1016/j.rec.2015.10.009 · Cited by 139
2020 Clinical practice guidelines for Acute coronary syndrome without ST segment elevation
Барбараш, О. Л., Duplyakov, D. V., Zateischikov, D. A., Панченко, Е. П., Shakhnovich, R. M., Yavelov, I. S., Yakovlev, A. N., Sa, A., Alekyan, B. G., Викторович, А. М., et al. (2021) · Russian Journal of Cardiology · doi:10.15829/1560-4071-2021-4449 · Cited by 147
An, Q., Gan, S., Xu, J., Bao, Y., Wu, T., Kong, H., Zhong, L., Ma, Y., Song, Z., & Niu, L. (2019) · Electrochemistry Communications · doi:10.1016/j.elecom.2019.106553 · Cited by 133
Recommendations for the standardization and interpretation of the electrocardiogram
Kligfield, P., Gettes, L. S., Bailey, J. J., Childers, R., Deal, B. J., Hancock, E. W., van Herpen, G., Kors, J. A., Macfarlane, P. W., Mirvis, D. M., et al. (2007) · Heart Rhythm · doi:10.1016/j.hrthm.2007.01.027 · Cited by 132
Self-citationQRS Complex Detection Using STFT, Chaos Analysis, and PCA in Standard and Real-Time ECG Databases
Gupta, V., & Mittal, M. (2019) · Journal of The Institution of Engineers (India) Series B · doi:10.1007/s40031-019-00398-9 · Cited by 130
Overview and Management of Cardiac Adverse Events Associated With Tyrosine Kinase Inhibitors
Lenihan, D. J., & Kowey, P. R. (2013) · The Oncologist · doi:10.1634/theoncologist.2012-0466 · Cited by 122
Brady, W. J., Gurka, K. K., Mehring, B., Peberdy, M. A., & O’Connor, R. E. (2011) · Resuscitation · doi:10.1016/j.resuscitation.2011.02.028 · Cited by 120
Steinberg, J. S., Varma, N., Cygankiewicz, I., Aziz, P. F., Balsam, P., Baranchuk, A. M., Cantillon, D. J., Dilaveris, P., Dubner, S., El‐Sherif, N., et al. (2017) · Annals of Noninvasive Electrocardiology · doi:10.1111/anec.12447 · Cited by 123
Gilbert, S., McGuire, A., Maghera, S., Sundaresan, S. R., SEELY, A. J. E., Maziak, D. E., Shamji, F. M., & Villeneuve, P. J. (2015) · Journal of Thoracic and Cardiovascular Surgery · doi:10.1016/j.jtcvs.2015.08.051 · Cited by 111
Bougouin, W., Marijon, É., Puymirat, É., Defaye, P., Celermajer, D. S., Heuzey, J. Y. L., Bovéda, S., Kacet, S., Mabo, P., BARNAY, C., et al. (2013) · European Heart Journal · doi:10.1093/eurheartj/eht453 · Cited by 110
Shah, R. (2010) · British Journal of Pharmacology · doi:10.1111/j.1476-5381.2009.00191.x · Cited by 103
Noujaim (2004) · doi:10.1161/01.cir.0000146785.15995.67 · Cited by 110
Charbit, B., Samain, E., Merckx, P., & Funck‐Brentano, C. (2006) · Anesthesiology · doi:10.1097/00000542-200602000-00009 · Cited by 109
Technical Mistakes during the Acquisition of the Electrocardiogram
García‐Niebla, J., Llontop-García, P., Valle‐Racero, J. I., Serra-Autonell, G., Batchvarov, V. N., & de Luna, A. B. (2009) · Annals of Noninvasive Electrocardiology · doi:10.1111/j.1542-474x.2009.00328.x · Cited by 108
Biometric Authentication Using Noisy Electrocardiograms Acquired by Mobile Sensors
Choi, H.-S., Lee, B., & Yoon, S. (2016) · IEEE Access · doi:10.1109/access.2016.2548519 · Cited by 107
Ureña, M., Hayek, S. S., Cheema, A. N., Serra, V., Amat-Santos, I. J., y, L. N.-F., Ribeiro, H. B., Allende, R., Paradis, J., Dumont, É., et al. (2014) · Circulation · doi:10.1161/circulationaha.114.011929 · Cited by 104
Dressler, R. M., Dryer, M. M., Coletti, C., Mahoney, D. D., & Doorey, A. J. (2014) · JAMA Internal Medicine · doi:10.1001/jamainternmed.2014.4491 · Cited by 102
Atzema, C., Schull, M. J., Borgundvaag, B., Slaughter, G. R. D., & Lee, C. K. (2006) · The American Journal of Emergency Medicine · doi:10.1016/j.ajem.2005.05.015 · Cited by 98
Internet of Healthcare Things: A contemporary survey
Ketu, S., & Mishra, P. K. (2021) · Journal of Network and Computer Applications · doi:10.1016/j.jnca.2021.103179 · Cited by 102
Stone, J. D., Ulman, H. K., Tran, K., Thompson, A. G., Halter, M. D., Ramadan, J. H., Stephenson, M., Finomore, V. S., Galster, S. M., Rezai, A. R., et al. (2021) · Frontiers in Sports and Active Living · doi:10.3389/fspor.2021.585870 · Cited by 107
Zhao, J., Han, S., Yang, Y., Fu, R., Yue, M., Lü, C., Liu, H., Gu, H., & Chen, W. (2017) · ACS Nano · doi:10.1021/acsnano.7b02767 · Cited by 98
AI-Enabled Wearable Medical Internet of Things in Healthcare System: A Survey
Subhan, F., Mirza, A., Su’ud, M. B. M., Alam, M. M., Nisar, S., Habib, U., & Iqbal, M. Z. (2023) · Applied Sciences · doi:10.3390/app13031394 · Cited by 116
Cardiac Monitoring of Human Subjects Exposed to the Taser®
Levine, S. D., Sloane, C. M., Chan, T. C., Dunford, J. V., & Vilke, G. M. (2007) · Journal of Emergency Medicine · doi:10.1016/j.jemermed.2007.02.018 · Cited by 96
Tirkkonen, J., Ylä-Mattila, J., Olkkola, K. T., Huhtala, H., Tenhunen, J. J., & Hoppu, S. (2012) · Resuscitation · doi:10.1016/j.resuscitation.2012.09.021 · Cited by 95
The Use of Wearable ECG Devices in the Clinical Setting: A Review
Kamga, P., Mostafa, R., & Zafar, S. (2022) · Current Emergency and Hospital Medicine Reports · doi:10.1007/s40138-022-00248-x · Cited by 94
2011 ACCF/AHA Guideline for Coronary Artery Bypass Graft Surgery: Executive Summary
Hillis, L. D., Smith, P. K., Anderson, J. L., Bittl, J. A., Bridges, C. R., Byrne, J. G., Cigarroa, J. E., DiSesa, V. J., Hiratzka, L. F., Hutter, A. M., et al. (2011) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2011.08.008 · Cited by 98
Tisdale, J. E., Wroblewski, H. A., Overholser, B. R., Kingery, J. R., Trujillo, T. N., & Kovacs, R. J. (2012) · Drug Safety · doi:10.2165/11598160-000000000-00000 · Cited by 85
Bussmann, J. B. J., Schrauwen, H. J., & Stam, H. J. (2008) · Archives of Physical Medicine and Rehabilitation · doi:10.1016/j.apmr.2007.11.012 · Cited by 85
Harjola, V., Parissis, J., Rocca, H. B., Čelutkienė, J., Chioncel, O., Collins, S. P., Backer, D. D., Filippatos, G. S., Gayat, É., Hill, L., et al. (2018) · European Journal of Heart Failure · doi:10.1002/ejhf.1204 · Cited by 81
Heffernan, K. S., Jae, S. Y., Vieira‐Potter, V. J., Iwamoto, G. A., Wilund, K. R., Woods, J. A., & Fernhall, B. (2009) · American Journal of Physiology-Regulatory, Integrative and Comparative Physiology · doi:10.1152/ajpregu.90936.2008 · Cited by 79
ECG monitoring leads and special leads
Francis, J. (2016) · Indian Pacing and Electrophysiology Journal · doi:10.1016/j.ipej.2016.07.003 · Cited by 79
Chou, R., Weimer, M. B., & Dana, T. (2014) · Journal of Pain · doi:10.1016/j.jpain.2014.01.495 · Cited by 75
Katal, N., Gupta, S., Verma, P., & Sharma, B. (2023) · Diagnostics · doi:10.3390/diagnostics13243605 · Cited by 72
Research Outcomes of Implementing CEASE
Lewis, C. L., & Oster, C. A. (2019) · Dimensions of Critical Care Nursing · doi:10.1097/dcc.0000000000000357 · Cited by 72
The Scoring of Cardiac Events During Sleep
Caples, S. M., ROSEN, C. L., Shen, W. K., Gami, A. S., Cotts, W., SUP, M. A. S., Dorostkar, P. C., Shivkumar, K., Somers, V. K., Morgenthaler, T. I., et al. (2007) · Journal of Clinical Sleep Medicine · doi:10.5664/jcsm.26816 · Cited by 71
Wearable Technology for Monitoring Electrocardiograms (ECGs) in Adults: A Scoping Review
Dahiya, E. S., Kalra, A. M., Lowe, A., & Anand, G. (2024) · Sensors · doi:10.3390/s24041318 · Cited by 69
FPGA-based system for artificial neural network arrhythmia classification
Zairi, H., Talha, M. K., Meddah, K., & Ould-Slimane, S. (2019) · Neural Computing and Applications · doi:10.1007/s00521-019-04081-4 · Cited by 66
Funk, M., Fennie, K., Stephens, K., May, J. L., Winkler, C. G., Drew, B. J., Borman, B., Calcasola, S., Carey, M. G., Currie, L., et al. (2017) · Circulation Cardiovascular Quality and Outcomes · doi:10.1161/circoutcomes.116.003132 · Cited by 64
Self-citationHeart Rate Variability Anatomy and Physiology
Shaffer, F., & Venner, J. (2013) · Biofeedback · doi:10.5298/1081-5937-41.1.05 · Cited by 70
Evaluation of dry textile electrodes for long-term electrocardiographic monitoring
Alizadeh-Meghrazi, M., Ying, B., Schlums, A., Lam, E., Eskandarian, L., Abbas, F., Sidhu, G., Mahnam, A., Moineau, B., & Popović, M. R. (2021) · BioMedical Engineering OnLine · doi:10.1186/s12938-021-00905-4 · Cited by 64
Managing alarm fatigue in cardiac care
Solet, J. M., & Barach, P. R. (2012) · Progress in Pediatric Cardiology · doi:10.1016/j.ppedcard.2011.12.014 · Cited by 61
Single Drop Whole Blood Diagnostics: Portable Biomedical Sensor for Cardiac Troponin I Detection
Sarangadharan, I., Wang, S.-L., Sukesan, R., Chen, P., Dai, T.-Y., Pulikkathodi, A. K., Hsu, C.-P., Chiang, H.-H. K., Liu, L. Y., & Wang, Y. (2018) · Analytical Chemistry · doi:10.1021/acs.analchem.7b05018 · Cited by 60
Alarm Fatigue: Use of an Evidence-Based Alarm Management Strategy
Turmell, J. W., Coke, L., Catinella, R., Hosford, T., & Majeski, A. (2017) · Journal of Nursing Care Quality · doi:10.1097/ncq.0000000000000223 · Cited by 59
GAZARIAN, P. K. (2013) · International Journal of Nursing Studies · doi:10.1016/j.ijnurstu.2013.05.014 · Cited by 59
Sivarajan, V. B., & BOHN, D. J. (2011) · Pediatric Critical Care Medicine · doi:10.1097/pcc.0b013e318220e7ea · Cited by 59
Prevalence and determinants of QT interval prolongation in medical inpatients
Pasquier, M., Pantet, O., Hügli, O., Pruvot, E. J., Buclin, T., Waeber, G., & Aujesky, D. (2011) · Internal Medicine Journal · doi:10.1111/j.1445-5994.2011.02447.x · Cited by 59
Soft, full Wheatstone bridge 3D pressure sensors for cardiovascular monitoring
Park, Y., Luan, H., Kwon, K., Chung, T. S., Oh, S., Yoo, J., Chung, G., Kim, J., Kim, S., Kwak, S. S., et al. (2024) · npj Flexible Electronics · doi:10.1038/s41528-024-00294-3 · Cited by 58
Drew, B. J., & Funk, M. (2006) · Critical Care Nursing Clinics of North America · doi:10.1016/j.ccell.2006.01.007 · Cited by 59
Self-citationKligfield, P., Badilini, F., Rowlandson, I., Xue, J. Q., Clark, E., Devine, B., Macfarlane, P. W., de Bie, J., MORTARA, D. W., Babaeizadeh, S., et al. (2013) · American Heart Journal · doi:10.1016/j.ahj.2013.10.004 · Cited by 57
Self-citationTelemedicine Applications for the Pediatric Emergency Medicine
Gattu, R. K., Teshome, G., & Lichenstein, R. (2016) · Pediatric Emergency Care · doi:10.1097/pec.0000000000000712 · Cited by 55
Self-Adherent Biodegradable Gelatin-Based Hydrogel Electrodes for Electrocardiography Monitoring
Lee, Y., Yim, S., Lee, G. W., Kim, S., Kim, H. S., Hwang, D. Y., An, B., Lee, J. H., Seo, S., & Yang, S. Y. (2020) · Sensors · doi:10.3390/s20205737 · Cited by 58
Autonomic Nervous System Responses to Concussion: Arterial Pulse Contour Analysis
Fountaine, M. F. L., Toda, M., Testa, A. J., & Hill-Lombardi, V. (2016) · Frontiers in Neurology · doi:10.3389/fneur.2016.00013 · Cited by 53
A Review on Human Healthcare Internet of Things: A Technical Perspective
Karthick, G. S., & Pankajavalli, P. B. (2020) · SN Computer Science · doi:10.1007/s42979-020-00205-z · Cited by 53
Kamousi, B., Karunakaran, S., Gururangan, K., Markert, M. S., Decker, B., Khankhanian, P., Mainardi, L., Quinn, J., Woo, R., & Parvizi, J. (2020) · Neurocritical Care · doi:10.1007/s12028-020-01120-0 · Cited by 52
Accurate interpretation of the 12-lead ECG electrode placement: A systematic review
Khunti, K. (2013) · Health Education Journal · doi:10.1177/0017896912472328 · Cited by 52
Nkolic-Heitzler, V., & Babic, Z. (2006) · European Heart Journal · doi:10.1093/eurheartj/ehl344 · Cited by 52
Is telemetry overused? Is it as helpful as thought?
Henriques-Forsythe, M. N., Ivonye, C. C., Jamched, U., Kamuguisha, L. K. K., Olejeme, K. A., & Onwuanyi, A. E. (2009) · Cleveland Clinic Journal of Medicine · doi:10.3949/ccjm.76a.07260 · Cited by 49
Funk, M., Winkler, C. G., May, J. L., Stephens, K., Fennie, K., Rose, L., Turkman, Y., & Drew, B. J. (2010) · Journal of Electrocardiology · doi:10.1016/j.jelectrocard.2010.07.018 · Cited by 49
Self-citationComputerized Interpretation of ECGs
Estes, N. A. M. (2013) · Circulation Arrhythmia and Electrophysiology · doi:10.1161/circep.111.000097 · Cited by 49
When Do Patients Need Admission to a Telemetry Bed?
Chen, E. H., & Hollander, J. E. (2007) · Journal of Emergency Medicine · doi:10.1016/j.jemermed.2007.01.017 · Cited by 50
Comparison of two teaching methods for cardiac arrhythmia interpretation among nursing students
Varvarousis, D., Kalafati, M., Pliatsika, P., Castrén, M. K., Lott, C., & Xanthos, T. T. (2013) · Resuscitation · doi:10.1016/j.resuscitation.2013.09.023 · Cited by 47
A description of nurses' decision‐making in managing electrocardiographic monitor alarms
GAZARIAN, P. K., Carrier, N., Cohen, R., Schram, H., & Shiromani, S. (2014) · Journal of Clinical Nursing · doi:10.1111/jocn.12625 · Cited by 47
Hyperglycemia Is Associated With Corrected QT Prolongation and Mortality in Acutely Ill Patients
Pickham, D. M., Flowers, E., & Drew, B. J. (2013) · The Journal of Cardiovascular Nursing · doi:10.1097/jcn.0b013e31827f174c · Cited by 46
Self-citationSignal Quality Analysis of Ambulatory Electrocardiograms to Gate False Myocardial Ischemia Alarms
Abdelazez, M., Quesnel, P. X., Chan, A. D. C., & Yang, H. (2016) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2016.2602283 · Cited by 46
Pitfalls and Artifacts in Electrocardiography
Drew, B. J. (2006) · Cardiology Clinics · doi:10.1016/j.ccl.2006.04.006 · Cited by 45
Self-citationRentz, L. E., Ulman, H. K., & Galster, S. M. (2021) · Sensors · doi:10.3390/s21155071 · Cited by 52
Metadata
- Authors
- Drew, B. J., Califf, R. M., Funk, M., Kaufman, E. S., Krucoff, M. W., Laks, M. M., Macfarlane, P. W., Sommargren, C., Swiryn, S., & Van Hare, G. F.
- Venue
- Circulation
- Published
- 2004-10-26
- Volume
- 110
- Issue
- 17
- Pages
- 2721-2746
- ISSN
- 0009-7322 (ISSN-L)
- 1524-4539
- OpenAlex
- W2768866949
- Cited by
- 609
- References
- 161
- Citations by year
- 2026: 26 · 2025: 23 · 2024: 20 · 2023: 24 · 2022: 25 · 2021: 30 · 2020: 27 · 2019: 27 · 2018: 25 · 2017: 36 · 2016: 43 · 2015: 45 · 2014: 36 · 2013: 41 · 2012: 23
- FWCI
- 12.66
- Type
- journal article
- Language
- en
- Update notices
- correction (2005-01-25)
- Open access
- closed
- Locations
- Circulation (publishedVersion)
- PubMed (publishedVersion)
- Topics
- Health Sciences › Medicine › Cardiology and Cardiovascular Medicine › ECG Monitoring and Analysis
- Health Sciences › Medicine › Surgery › Healthcare Technology and Patient Monitoring
- Health Sciences › Medicine › Cardiology and Cardiovascular Medicine › Cardiac electrophysiology and arrhythmias
- Keywords
- ECG monitoring, arrhythmia detection, QT interval monitoring, myocardial ischemia, QT prolongation, computerized ECG analysis, ECG lead systems, quality improvement, proarrhythmic drugs
- MeSH terms
- Workforce, Arrhythmias, Cardiac, Cardiology, Electrocardiography, Electrodes, Hospitalization, Humans, Long QT Syndrome, Monitoring, Physiologic, Myocardial Ischemia
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review