In Vivo Tracking of Stem Cells for Clinical Trials in Cardiovascular Disease
The DOI matches its Crossref record; 42 of the 42 references it cites were found in a registry or an index.
Abstract
Various stem cells hold promise for the treatment of human cardiovascular disease. Regardless of stem cell origin, future clinical trials will require that the location and number of such cells be tracked in vivo, over long periods of time. The problem of tracking small numbers of cells in the body is a difficult one, and an optimal solution does not yet exist. We review the many contrast agents and detectors that have been proposed for stem cell tracking during clinical trials, define the characteristics of an ideal imaging technology, and suggest future directions for research.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
LMO2 -Associated Clonal T Cell Proliferation in Two Patients after Gene Therapy for SCID-X1
Hacein-Bey-Abina, S., Von Kalle, C., Schmidt, M., McCormack, M. P., Wulffraat, N., Leboulch, P., Lim, A., Osborne, C. S., Pawliuk, R., Morillon, E., et al. (2003) · Science · doi:10.1126/science.1088547 · Cited by 3,587
In vivo near-infrared fluorescence imaging
Frangioni, J. V. (2003) · Current Opinion in Chemical Biology · doi:10.1016/j.cbpa.2003.08.007 · Cited by 2,653
Self-citationNear-infrared fluorescent type II quantum dots for sentinel lymph node mapping
Kim, S., Lim, Y. T., Soltesz, E. G., De Grand, A. M., Lee, J., Nakayama, A., Parker, J. A., Mihaljevic, T., Laurence, R. G., Dor, D. M., et al. (2004) · Nature Biotechnology · doi:10.1038/nbt920 · Cited by 2,087
Self-citationLewin, M., Carlesso, N., Tung, C.-H., Tang, X.-W., Cory, D., Scadden, D. T., & Weissleder, R. (2000) · Nature Biotechnology · doi:10.1038/74464 · Cited by 1,716
Barbash, I. M., Chouraqui, P., Baron, J., Feinberg, M. S., Etzion, S., Tessone, A., Miller, L., Guetta, E., Zipori, D., Kedes, L. H., et al. (2003) · Circulation · doi:10.1161/01.cir.0000084828.50310.6a · Cited by 1,197
Magnetodendrimers allow endosomal magnetic labeling and in vivo tracking of stem cells
Bulte, J. W. M., Douglas, T., Witwer, B., Zhang, S.-C., Strable, E., Lewis, B. K., Zywicke, H., Miller, B., van Gelderen, P., Moskowitz, B. M., et al. (2001) · Nature Biotechnology · doi:10.1038/nbt1201-1141 · Cited by 1,027
Ntziachristos, V., Bremer, C., & Weissleder, R. (2003) · European Radiology · doi:10.1007/s00330-002-1524-x · Cited by 982
The Dynamic in vivo Distribution of Bone Marrow-Derived Mesenchymal Stem Cells after Infusion
Gao, J., Dennis, J. E., Muzic, R. F., Lundberg, M., & Caplan, A. I. (2001) · Cells Tissues Organs · doi:10.1159/000047856 · Cited by 951
High-Efficiency Intracellular Magnetic Labeling with Novel Superparamagnetic-Tat Peptide Conjugates
Josephson, L., Tung, C.-H., Moore, A., & Weissleder, R. (1999) · Bioconjugate Chemistry · doi:10.1021/bc980125h · Cited by 882
Frank, J. A., Miller, B. R., Arbab, A. S., Zywicke, H. A., Jordan, E. K., Lewis, B. K., Bryant, L. H., & Bulte, J. W. M. (2003) · Radiology · doi:10.1148/radiol.2281020638 · Cited by 643
Cited by
New Technologies for Human Cancer Imaging
Frangioni, J. V. (2008) · Journal of Clinical Oncology · doi:10.1200/jco.2007.14.3065 · Cited by 800
Self-citationFreyman, T., Polin, G., Osman, H., Crary, J., Lu, M., Cheng, L., Palasis, M., & Wilensky, R. L. (2006) · European Heart Journal · doi:10.1093/eurheartj/ehi818 · Cited by 613
Cao, F., Lin, S., Xie, X., Ray, P., Patel, M., Zhang, X., Drukker, M., Dylla, S. J., Connolly, A. J., Chen, X., et al. (2006) · Circulation · doi:10.1161/circulationaha.105.588954 · Cited by 493
Klibanov, A. L. (2006) · Investigative Radiology · doi:10.1097/01.rli.0000199292.88189.0f · Cited by 424
Valina, C., Pinkernell, K., Song, Y.-H., Bai, X., Sadat, S., Campeau, R. J., Le Jemtel, T. H., & Alt, E. (2007) · European Heart Journal · doi:10.1093/eurheartj/ehm426 · Cited by 390
Cellular imaging in drug discovery
Lang, P., Yeow, K., Nichols, A., & Scheer, A. (2006) · Nature Reviews Drug Discovery · doi:10.1038/nrd2008 · Cited by 351
Biocompatibility and Toxicity of Magnetic Nanoparticles in Regenerative Medicine
Markides, H., Rotherham, M., & El Haj, A. J. (2012) · Journal of Nanomaterials · doi:10.1155/2012/614094 · Cited by 332
Magnetic Particle Imaging (MPI) for NMR and MRI researchers
Saritas, E. U., Goodwill, P. W., Croft, L. R., Konkle, J. J., Lu, K., Zheng, B., & Conolly, S. M. (2013) · Journal of Magnetic Resonance · doi:10.1016/j.jmr.2012.11.029 · Cited by 307
Modo, M., Hoehn, M., & Bulte, J. W. M. (2005) · Molecular Imaging · doi:10.1162/15353500200505145 · Cited by 294
Molecular SPECT Imaging: An Overview
Khalil, M. M., Tremoleda, J. L., Bayomy, T. B., & Gsell, W. (2011) · International Journal of Molecular Imaging · doi:10.1155/2011/796025 · Cited by 275
Terrovitis, J., Lautamäki, R., Bonios, M., Fox, J., Engles, J. M., Yu, J., Leppo, M. K., Pomper, M. G., Wahl, R. L., Seidel, J., et al. (2009) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2009.04.097 · Cited by 268
Terrovitis, J., Stuber, M., Youssef, A., Preece, S., Leppo, M., Kizana, E., Schär, M., Gerstenblith, G., Weiss, R. G., Marbán, E., et al. (2008) · Circulation · doi:10.1161/circulationaha.107.732073 · Cited by 268
Molecular imaging with nanoparticles: giant roles for dwarf actors
Debbage, P., & Jaschke, W. (2008) · Histochemistry and Cell Biology · doi:10.1007/s00418-008-0511-y · Cited by 264
Technology Insight: in vivo cell tracking by use of MRI
Rogers, W. J., Meyer, C. H., & Kramer, C. M. (2006) · Nature Clinical Practice Cardiovascular Medicine · doi:10.1038/ncpcardio0659 · Cited by 249
Madonna, R., Van Laake, L. W., Davidson, S. M., Engel, F. B., Hausenloy, D. J., Lecour, S., Leor, J., Perrino, C., Schulz, R., Ytrehus, K., et al. (2016) · European Heart Journal · doi:10.1093/eurheartj/ehw113 · Cited by 243
Small-Animal SPECT and SPECT/CT: Important Tools for Preclinical Investigation
Franc, B. L., Acton, P. D., Mari, C., & Hasegawa, B. H. (2008) · Journal of Nuclear Medicine · doi:10.2967/jnumed.108.055442 · Cited by 242
“Tracking small numbers of radiolabeled cells in the living body is extremely difficult, and an optimal solution does not yet exist (69).”
BackgroundMolecular Imaging of Cardiovascular Disease
Jaffer, F. A., Libby, P., & Weissleder, R. (2007) · Circulation · doi:10.1161/circulationaha.106.647164 · Cited by 218
Rosen, A. B., Kelly, D. J., Schuldt, A. J. T., Lu, J., Potapova, I. A., Doronin, S. V., Robichaud, K. J., Robinson, R. B., Rosen, M. R., Brink, P. R., et al. (2007) · Stem Cells · doi:10.1634/stemcells.2006-0722 · Cited by 211
Molecular Body Imaging: MR Imaging, CT, and US. Part I. Principles
Kircher, M. F., & Willmann, J. K. (2012) · Radiology · doi:10.1148/radiol.12102394 · Cited by 209
Cell therapy and the safety of embryonic stem cell-derived grafts
Hentze, H., Graichen, R., & Colman, A. (2007) · Trends in Biotechnology · doi:10.1016/j.tibtech.2006.10.010 · Cited by 197
Cell tracking with optical imaging
Sutton, E. J., Henning, T. D., Pichler, B. J., Bremer, C., & Daldrup-Link, H. E. (2008) · European Radiology · doi:10.1007/s00330-008-0984-z · Cited by 178
“Stem cells as well as mononuclear cells, skeletal muscle cells, cardiomyocytes, hematopoietic cells and endothelial cells have been used in cardiovascular disease to treat ischemic injury leading to improved myocardial function, while the mechanism remains undefined [2, 52].”
BackgroundInfluentialTerrovitis, J., Kwok, K. F., Lautamäki, R., Engles, J. M., Barth, A. S., Kizana, E., Miake, J., Leppo, M. K., Fox, J., Seidel, J., et al. (2008) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2008.06.051 · Cited by 162
“nderstanding stem cell biology, optimizing engraftment, nd maximizing the functional benefits of stem cell therapy n the heart (8).”
BackgroundGyöngyösi, M., Blanco, J., Marian, T., Trón, L., Petneházy, O., Petrasi, Z., Hemetsberger, R., Rodriguez, J., Font, G., Pavo, I. J., et al. (2008) · Circulation: Cardiovascular Imaging · doi:10.1161/circimaging.108.797449 · Cited by 159
Metadata
- Authors
- Frangioni, J. V., & Hajjar, R. J.
- Venue
- Circulation
- Published
- 2004-11-23
- Volume
- 110
- Issue
- 21
- Pages
- 3378-3383
- ISSN
- 0009-7322 (ISSN-L)
- 1524-4539
- OpenAlex
- W2096045982
- Cited by
- 269
- References
- 42
- FWCI
- 11.50
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.