Ventilatory and Heart Rate Responses to Exercise: Better Predictors of Heart Failure Mortality Than Peak Oxygen Consumption
Open accessThe DOI matches its Crossref record; 20 of the 20 references it cites were found in a registry or an index.
Abstract
Background —An abnormally low chronotropic response and an abnormally high ventilatory response (V̇ e /V̇ co 2 ) to exercise are common in patients with severe heart failure, but their relative prognostic impacts have not been well explored. Methods and Results —Consecutive patients with heart failure referred for metabolic stress testing who were not taking β-blockers or intravenous inotropes (n=470) were followed for 1.5 years. The chronotropic index was calculated while peak V̇ o 2 and V̇ e /V̇ co 2 were directly measured. Chronotropic index and peak V̇ o 2 were considered abnormal if in the lowest 25th percentiles of the patient cohort, whereas V̇ e /V̇ co 2 was considered abnormal if in the highest 25th percentile. For comparative purposes, a group of 17 healthy controls underwent metabolic testing as well. Compared with controls, heart failure patients had markedly abnormal ventilatory and chronotropic responses to exercise. In the heart failure cohort, there were 71 deaths. In univariate analyses, predictors of death included high V̇ e /V̇ co 2 , low chronotropic index, low V̇ o 2 , low resting systolic blood pressure, and older age. Nonparametric Kaplan-Meier plots demonstrated that by dividing the population according to peak V̇ e /V̇ co 2 and peak V̇ o 2 , it is possible to identify low, intermediate, and very high risk groups. In multivariate analyses, the only independent predictors of death were high V̇ e /V̇ co 2 (adjusted relative risk [RR] 3.20, 95% CI 1.95 to 5.26, P <0.0001) and low chronotropic index (adjusted RR 1.94, 95% CI 1.18 to 3.19, P =0.0009). Conclusions —The ventilatory and chronotropic responses to exercise are powerful and independent predictors of heart failure mortality.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
A new method for detecting anaerobic threshold by gas exchange
Beaver, W. L., Wasserman, K., & Whipp, B. J. (1986) · Journal of Applied Physiology · doi:10.1152/jappl.1986.60.6.2020 · Cited by 4,103
Mancini, D. M., Eisen, H., Kussmaul, W., Mull, R., Edmunds, L. H., & Wilson, J. R. (1991) · Circulation · doi:10.1161/01.cir.83.3.778 · Cited by 1,882
(1993) · Archives of Internal Medicine · doi:10.1001/archinte.1993.00410020010002 · Cited by 1,608
Nolan, J., Batin, P. D., Andrews, R., Lindsay, S. J., Brooksby, P., Mullen, M., Baig, W., Flapan, A. D., Cowley, A., Prescott, R. J., et al. (1998) · Circulation · doi:10.1161/01.cir.98.15.1510 · Cited by 1,179
Blackstone, E. H., Naftel, D. C., & Turner, M. E. (1986) · Journal of the American Statistical Association · doi:10.1080/01621459.1986.10478314 · Cited by 646
Chua, T. P., Ponikowski, P., Harrington, D., Anker, S. D., Webb-Peploe, K., Clark, A. L., Poole-Wilson, P. A., & Coats, A. J. S. (1997) · Journal of the American College of Cardiology · doi:10.1016/s0735-1097(97)00078-8 · Cited by 563
Lauer, M. S., Okin, P. M., Larson, M. G., Evans, J. C., & Levy, D. (1996) · Circulation · doi:10.1161/01.cir.93.8.1520 · Cited by 530
Self-citationColucci, W. S., Ribeiro, J. P., Rocco, M. B., Quigg, R. J., Creager, M. A., Marsh, J. D., Gauthier, D. F., & Hartley, L. H. (1989) · Circulation · doi:10.1161/01.cir.80.2.314 · Cited by 372
Stelken, A. M., Younis, L. T., Jennison, S. H., Douglas Miller, D., Miller, L. W., Shaw, L. J., Kargl, D., & Chaitman, B. R. (1996) · Journal of the American College of Cardiology · doi:10.1016/0735-1097(95)00464-5 · Cited by 342
Myers, J., Gullestad, L., Vagelos, R., Do, D., Bellin, D., Ross, H., & Fowler, M. B. (1998) · Annals of Internal Medicine · doi:10.7326/0003-4819-129-4-199808150-00004 · Cited by 271
Cited by
Balady, G. J., Arena, R., Sietsema, K., Myers, J., Coke, L., Fletcher, G. F., Forman, D., Franklin, B., Guazzi, M., Gulati, M., et al. (2010) · Circulation · doi:10.1161/cir.0b013e3181e52e69 · Cited by 1,964
Recommendations on the use of exercise testing in clinical practice
Palange, P., Ward, S. A., Carlsen, K.-H., Casaburi, R., Gallagher, C. G., Gosselink, R., O'Donnell, D. E., Puente-Maestu, L., Schols, A. M., Singh, S., et al. (2007) · European Respiratory Journal · doi:10.1183/09031936.00046906 · Cited by 718
Cardiopulmonary exercise testing and its application
Albouaini, K., Egred, M., Alahmar, A., & Wright, D. J. (2007) · Postgraduate Medical Journal · doi:10.1136/hrt.2007.121558 · Cited by 582
Abraham, W. T., Young, J. B., León, A. R., Adler, S., Bank, A. J., Hall, S. A., Lieberman, R., Liem, L. B., O’Connell, J. B., Schroeder, J. S., et al. (2004) · Circulation · doi:10.1161/01.cir.0000146336.92331.d1 · Cited by 559
Self-citationPeak VO2 and VE/VCO2 slope in patients with heart failure: a prognostic comparison
Arena, R., Myers, J., Aslam, S. S., Varughese, E. B., & Peberdy, M. A. (2004) · American Heart Journal · doi:10.1016/j.ahj.2003.07.014 · Cited by 464
Development of a Ventilatory Classification System in Patients With Heart Failure
Arena, R., Myers, J., Abella, J., Peberdy, M. A., Bensimhon, D., Chase, P., & Guazzi, M. (2007) · Circulation · doi:10.1161/circulationaha.107.686576 · Cited by 391
Meyer, F. J., Borst, M. M., Zugck, C., Kirschke, A., Schellberg, D., Kübler, W., & Haass, M. (2001) · Circulation · doi:10.1161/01.cir.103.17.2153 · Cited by 296
Peak Oxygen Consumption as a Predictor of Death in Patients With Heart Failure Receiving β-Blockers
O’Neill, J. O., Young, J. B., Pothier, C. E., & Lauer, M. S. (2005) · Circulation · doi:10.1161/01.cir.0000164270.72123.18 · Cited by 277
Self-citationArena, R., Myers, J., & Guazzi, M. (2008) · Heart Failure Reviews · doi:10.1007/s10741-007-9067-5 · Cited by 268
Peled, Y., Ducharme, A., Kittleson, M., Bansal, N., Stehlik, J., Amdani, S., Saeed, D., Cheng, R., Clarke, B., Dobbels, F., et al. (2024) · The Journal of Heart and Lung Transplantation · doi:10.1016/j.healun.2024.05.010 · Cited by 240
MacGowan, G. A., & Murali, S. (2000) · Circulation · doi:10.1161/01.cir.102.24.e182 · Cited by 234
A cardiopulmonary exercise testing score for predicting outcomes in patients with heart failure
Myers, J., Arena, R., Dewey, F., Bensimhon, D., Abella, J., Hsu, L., Chase, P., Guazzi, M., & Peberdy, M. A. (2008) · American Heart Journal · doi:10.1016/j.ahj.2008.07.010 · Cited by 204
Cardiopulmonary Exercise Testing and Prognosis in Hypertrophic Cardiomyopathy
Coats, C. J., Rantell, K., Bartnik, A., Patel, A., Mist, B., McKenna, W. J., & Elliott, P. M. (2015) · Circulation: Heart Failure · doi:10.1161/circheartfailure.114.002248 · Cited by 148
Early heart rate recovery after exercise predicts mortality in patients with chronic heart failure
Nanas, S., Anastasiou-Nana, M., Dimopoulos, S., Sakellariou, D., Alexopoulos, G., Kapsimalakou, S., Papazoglou, P., Tsolakis, E., Papazachou, O., Roussos, C., et al. (2006) · International Journal of Cardiology · doi:10.1016/j.ijcard.2005.10.032 · Cited by 93
Metadata
- Authors
- Robbins, M., Francis, G., Pashkow, F. J., Snader, C. E., Hoercher, K., Young, J. B., & Lauer, M. S.
- Venue
- Circulation
- Published
- 1999-12-14
- Volume
- 100
- Issue
- 24
- Pages
- 2411-2417
- ISSN
- 0009-7322 (ISSN-L)
- 1524-4539
- OpenAlex
- W2922117482
- Cited by
- 219
- References
- 20
- FWCI
- 19.42
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.