The DOI matches its Crossref record; 20 of the 20 references it cites were found in a registry or an index.
Noninvasive Ultrasound Imaging of Inflammation Using Microbubbles Targeted to Activated Leukocytes
Abstract
Background—Lipid microbubbles used for perfusion imaging with ultrasound are retained within inflamed tissue because of complement-mediated attachment to leukocytes within venules. We hypothesized that incorporation of phosphatidylserine (PS) into the microbubble shell may enhance these interactions by amplifying complement activation and thereby allow ultrasound imaging of inflammation. Methods and Results—In 6 mice, intravital microscopy of tissue necrosis factor-α–treated cremaster muscle was performed to assess the microvascular behavior of fluorescein-labeled lipid microbubbles with and without PS in the shell. Ten minutes after intravenous injection, microbubble attachment to leukocytes within inflamed venules was greater for PS-containing than for standard lipid microbubbles (20±4 versus 10±3 per 20 optical fields,P<0.05). The ultrasound signal from retained microbubbles was assessed in the kidneys of 6 mice undergoing renal ischemia-reperfusion injury and in 6 control kidneys. The signal from retained microbubbles in control kidneys was low (<2.5 video intensity units) for both agents. After ischemia-reperfusion, the signal from retained microbubbles was 2-fold higher for PS-containing than for standard lipid microbubbles (18±6 versus 8±2 video intensity units,P<0.05). An excellent relation was found between the ultrasound signal from retained microbubbles and the degree of renal inflammation, assessed by tissue myeloperoxidase activity. Conclusions—We conclude that noninvasive assessment of inflammation is possible by ultrasound imaging of microbubbles targeted to activated leukocytes by the presence of PS in the lipid shell.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Wei, K., Jayaweera, A. R., Firoozan, S., Linka, A., Skyba, D. M., & Kaul, S. (1998) · Circulation · doi:10.1161/01.cir.97.5.473 · Cited by 1,616
Self-citationSavill, J., Hogg, N., Ren, Y., & Haslett, C. (1992) · Journal of Clinical Investigation · doi:10.1172/jci116019 · Cited by 813
The Class B Scavenger Receptors SR-BI and CD36 Are Receptors for Anionic Phospholipids
Rigotti, A., Acton, S. L., & Krieger, M. (1995) · Journal of Biological Chemistry · doi:10.1074/jbc.270.27.16221 · Cited by 557
Fadok, V. A., Warner, M. L., Bratton, D. L., & Henson, P. M. (1998) · PubMed · Cited by 406
Chonn, A., Cullis, P. R., & Devine, D. V. (1991) · The Journal of Immunology · doi:10.4049/jimmunol.146.12.4234 · Cited by 367
Fadok, V. A., Warner, M. L., Bratton, D. L., & Henson, P. M. (1998) · The Journal of Immunology · doi:10.4049/jimmunol.161.11.6250 · Cited by 354
Allen, T. M., Austin, G. A., Chonn, A., Lin, L., & Lee, K. C. (1991) · Biochimica et Biophysica Acta (BBA) - Biomembranes · doi:10.1016/0005-2736(91)90268-d · Cited by 345
Jung, U., Norman, K. E., Scharffetter-Kochanek, K., Beaudet, A. L., & Ley, K. (1998) · Journal of Clinical Investigation · doi:10.1172/jci119893 · Cited by 275
Self-citationKeller, M. W., Segal, S. S., Kaul, S., & Duling, B. (1989) · Circulation Research · doi:10.1161/01.res.65.2.458 · Cited by 267
Self-citationLiposome—complement interactions in rat serum: implications for liposome survival studies
Devine, D. V., Wong, K., Serrano, K., Chonn, A., & Cullis, P. R. (1994) · Biochimica et Biophysica Acta (BBA) - Biomembranes · doi:10.1016/0005-2736(94)90231-3 · Cited by 248
Cited by
Microbubbles in medical imaging: current applications and future directions
Lindner, J. R. (2004) · Nature Reviews Drug Discovery · doi:10.1038/nrd1417 · Cited by 872
Self-citationTherapeutic applications of lipid-coated microbubbles
Unger, E. C., Porter, T., Culp, W., Labell, R., Matsunaga, T., & Zutshi, R. (2004) · Advanced Drug Delivery Reviews · doi:10.1016/j.addr.2003.12.006 · Cited by 591
Schutt, E. G., Klein, D. H., Mattrey, R. M., & Riess, J. G. (2003) · Angewandte Chemie International Edition · doi:10.1002/anie.200200550 · Cited by 543
Imaging Tumor Angiogenesis With Contrast Ultrasound and Microbubbles Targeted to α v β 3
Ellegala, D. B., Leong-Poi, H., Carpenter, J. E., Klibanov, A. L., Kaul, S., Shaffrey, M. E., Sklenar, J., & Lindner, J. R. (2003) · Circulation · doi:10.1161/01.cir.0000080326.15367.0c · Cited by 454
Self-citationLindner, J. R., Song, J., Christiansen, J., Klibanov, A. L., Xu, F., & Ley, K. (2001) · Circulation · doi:10.1161/hc4201.097061 · Cited by 441
Self-citation
Metadata
- Authors
- Lindner, J. R., Song, J., Xu, F., Klibanov, A. L., Singbartl, K., Ley, K., & Kaul, S.
- Venue
- Circulation
- Published
- 2000-11-28
- Volume
- 102
- Issue
- 22
- Pages
- 2745-2750
- ISSN
- 0009-7322 (ISSN-L)
- 1524-4539
- OpenAlex
- W2144870723
- Cited by
- 286
- References
- 20
- FWCI
- 11.79
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Noninvasive Ultrasound Imaging of Inflammation Using Microbubbles Targeted to Activated Leukocytes. https://app.cochat.ai/papers/10.1161/01.cir.102.22.2745
- The paper
- Lindner, J. R., Song, J., Xu, F., Klibanov, A. L., Singbartl, K., Ley, K., & Kaul, S. (2000). Noninvasive Ultrasound Imaging of Inflammation Using Microbubbles Targeted to Activated Leukocytes. Circulation. https://doi.org/10.1161/01.cir.102.22.2745
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.