CoChat

A fourth criterion for transient entrainment: the electrogram equivalent of progressive fusion.

Open access
Henthorn, R W, Okumura, K, Olshansky, B, Plumb, V J, Hess, P G, Waldo, A L · 1988 · Circulation
Cited by 141

The DOI matches its Crossref record.

Abstract

Prior data pertaining to transient entrainment and associated phenomena have been best explained by pacing capture of a reentrant circuit. On this basis, we hypothesized that rapid pacing from a single site of two different constant pacing rates could constantly capture an appropriately selected bipolar electrogram recording site from one direction with a constant stimulus-to-electrogram interval during pacing at one rate, yet be constantly captured from another direction with a different constant stimulus-to-electrogram interval when pacing at a different constant pacing rate. To test this hypothesis, we studied a group of patients, each with a representative tachycardia (ventricular tachycardia, circus-movement tachycardia involving an atrioventricular bypass pathway, atrial tachycardia, and atrial flutter). For each tachycardia, pacing was performed from a single site for at least two different constant rates faster than the spontaneous rate of the tachycardia. We observed in these patients that a local bipolar recording site was constantly captured from different directions at two different pacing rates without interrupting the tachycardia at pacing termination. The evidence that the same site was captured from a different direction at two different pacing rates was supported by demonstrating a change in conduction time to that site associated with a change in the bipolar electrogram morphology at that site when comparing pacing at each rate. The mean conduction time (stimulus-to-recording site electrogram interval) was 319 +/- 69 msec while pacing at a mean cycle length of 265 +/- 50 msec, yet only 81 +/- 38 msec while pacing at a second mean cycle length of 233 +/- 51 msec, a mean change in conduction time of 238 +/- 56 msec. Remarkably, the faster pacing rate resulted in a shorter conduction time. The fact that the same electrode recording site was activated from different directions without interruption of the spontaneous tachycardia at pacing termination is difficult to explain on any mechanistic basis other than reentry. Also, these changes in conduction time and electrogram morphology occurred in parallel with the demonstration of progressive fusion beats on the electrocardiogram, the latter being an established criterion for transient entrainment.(ABSTRACT TRUNCATED AT 400 WORDS)

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1161/01.cir.77.5.1003

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

Metadata

Authors
Henthorn, R. W., Okumura, K., Olshansky, B., Plumb, V. J., Hess, P. G., & Waldo, A. L.
Venue
Circulation
Published
1988-05
Volume
77
Issue
5
Pages
1003-1012
ISSN
  • 0009-7322 (ISSN-L)
  • 1524-4539
OpenAlex
W2096794679
Cited by
141
References
0
FWCI
5.79
Type
journal article
Language
en
Open access
bronze

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.