The DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.
Chronic atrial fibrillation and stroke in paced patients with sick sinus syndrome. Relevance of clinical characteristics and pacing modalities.
Abstract
BACKGROUND: The goal of the report was to study the long-term incidence and the independent predictors for chronic atrial fibrillation and stroke in 507 paced patients with sick sinus syndrome, adjusting for differences in baseline clinical variables with multivariate analysis. METHODS AND RESULTS: From 1980 to 1989, we implanted 376 dual-chamber, 19 atrial, and 112 ventricular pacemakers to treat patients with sick sinus syndrome. After a maximum follow-up of 134 months (mean: 59 +/- 38 months for chronic atrial fibrillation, 65 +/- 37 months for stroke), actuarial incidence of chronic atrial fibrillation was 7% at 1 year, 16% at 5 years, and 28% at 10 years. Independent predictors for this event, from Cox's proportional hazards model, were history of paroxysmal atrial fibrillation (P < .001; hazard ratio [HR] = 16.84), use of antiarrhythmic drugs before pacemaker implant (P < .001; HR = 2.25), ventricular pacing mode (P = .003; HR = 1.98), age (P = .005; HR = 1.03), and valvular heart disease (P = .008; HR = 2.05). For patients with preimplant history of paroxysmal atrial fibrillation, independent predictors were prolonged episodes of paroxysmal atrial fibrillation (P < .001; HR = 2.56), long history of paroxysmal atrial fibrillation (P = .004; HR = 2.05), ventricular pacing mode (P = .025; HR = 1.69), use of antiarrhythmic drugs before pacemaker implant (P = .024; HR = 1.71), and age (P = .04; HR = 1.02). Actuarial incidence of stroke was 3% at 1 year, 5% at 5 years, and 13% at 10 years. Independent predictors for stroke were history of cerebrovascular disease (P < .001; HR = 5.22), ventricular pacing mode (P = .008; HR = 2.61), and history of paroxysmal atrial fibrillation (P = .037; HR = 2.81). CONCLUSIONS: Development of chronic atrial fibrillation and stroke in paced patients with sick sinus syndrome are strongly determined by clinical variables and secondarily by the pacing modality. Ventricular pacing mode predicts chronic atrial fibrillation in patients with preimplant paroxysmal atrial fibrillation but not in those without it.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Atrial fibrillation as an independent risk factor for stroke: the Framingham study
Wolf, P. A., Abbott, R. D., & Kannel, W. B. (1991) · Stroke · doi:10.1161/01.str.22.8.983 · Cited by 7,388
Atrial enlargement as a consequence of atrial fibrillation. A prospective echocardiographic study.
Sanfilippo, A. J., Abascal, V. M., Sheehan, M., Oertel, L. B., Harrigan, P., Hughes, R. A., & Weyman, A. E. (1990) · Circulation · doi:10.1161/01.cir.82.3.792 · Cited by 739
SASAKI, Y., SHIMOTORI, M., AKAHANE, K., YONEKURA, H., HIRANO, K., ENDOH, R., KOIKE, S., KAWA, S., FURUTA, S., & HOMMA, T. (1988) · Pacing and Clinical Electrophysiology · doi:10.1111/j.1540-8159.1988.tb06277.x · Cited by 109
Cited by
Andersen, H. R., Nielsen, J. C., Thomsen, P. E. B., Thuesen, L., Mortensen, P. T., Vesterlund, T., & Pedersen, A. K. (1997) · The Lancet · doi:10.1016/s0140-6736(97)03425-9 · Cited by 841
Glotzer, T. V., Hellkamp, A. S., Zimmerman, J., Sweeney, M. O., Yee, R., Marinchak, R., Cook, J., Paraschos, A., Love, J., Radoslovich, G., et al. (2003) · Circulation · doi:10.1161/01.cir.0000057981.70380.45 · Cited by 750
Prystowsky, E. N., Benson, D. W., Fuster, V., Hart, R. G., Kay, G. N., Myerburg, R. J., Naccarelli, G. V., & Wyse, D. G. (1996) · Circulation · doi:10.1161/01.cir.93.6.1262 · Cited by 635
Eikelboom, J. W., Anand, S. S., Malmberg, K., Weitz, J. I., Ginsberg, J. S., & Yusuf, S. (2000) · The Lancet · doi:10.1016/s0140-6736(00)02324-2 · Cited by 447
Prevention of recurrent atrial fibrillation with chronic dual-site right atrial pacing
Saksena, S., Prakash, A., Hill, M., Krol, R. B., Munsif, A. N., Mathew, P. P., & Mehra, R. (1996) · Journal of the American College of Cardiology · doi:10.1016/0735-1097(96)00232-x · Cited by 325
Guidelines for clinical intracardiac electrophysiological and catheter ablation procedures
Zipes, D. P., Dimarco, J. P., Gillette, P. C., Jackman, W. M., Myerburg, R. J., Rahimtoola, S. H., Ritchie, J. L., Cheitlin, M. D., Garson, A., Gibbons, R. J., et al. (1995) · Journal of the American College of Cardiology · doi:10.1016/0735-1097(95)80037-h · Cited by 282
Alboni, P., Menozzi, C., Brignole, M., Paparella, N., Gaggioli, G., Lolli, G., & Cappato, R. (1997) · Circulation · doi:10.1161/01.cir.96.1.260 · Cited by 166
Metadata
- Authors
- Sgarbossa, E. B., Pinski, S. L., Maloney, J. D., Simmons, T. W., Wilkoff, B. L., Castle, L. W., & Trohman, R. G.
- Venue
- Circulation
- Published
- 1993-09
- Volume
- 88
- Issue
- 3
- Pages
- 1045-1053
- ISSN
- 0009-7322 (ISSN-L)
- 1524-4539
- OpenAlex
- W2066171379
- Cited by
- 203
- References
- 3
- FWCI
- 4.98
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.