Student or educator? Sign up with your school email and get 6 months of Pro free.
CoChat
Cited by 203

The DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.

Chronic atrial fibrillation and stroke in paced patients with sick sinus syndrome. Relevance of clinical characteristics and pacing modalities.

Sgarbossa, E B, Pinski, S L, Maloney, J D, Simmons, T W, Wilkoff, B L, Castle, L W, Trohman, R G · 1993 · Circulation

Abstract

BACKGROUND: The goal of the report was to study the long-term incidence and the independent predictors for chronic atrial fibrillation and stroke in 507 paced patients with sick sinus syndrome, adjusting for differences in baseline clinical variables with multivariate analysis. METHODS AND RESULTS: From 1980 to 1989, we implanted 376 dual-chamber, 19 atrial, and 112 ventricular pacemakers to treat patients with sick sinus syndrome. After a maximum follow-up of 134 months (mean: 59 +/- 38 months for chronic atrial fibrillation, 65 +/- 37 months for stroke), actuarial incidence of chronic atrial fibrillation was 7% at 1 year, 16% at 5 years, and 28% at 10 years. Independent predictors for this event, from Cox's proportional hazards model, were history of paroxysmal atrial fibrillation (P < .001; hazard ratio [HR] = 16.84), use of antiarrhythmic drugs before pacemaker implant (P < .001; HR = 2.25), ventricular pacing mode (P = .003; HR = 1.98), age (P = .005; HR = 1.03), and valvular heart disease (P = .008; HR = 2.05). For patients with preimplant history of paroxysmal atrial fibrillation, independent predictors were prolonged episodes of paroxysmal atrial fibrillation (P < .001; HR = 2.56), long history of paroxysmal atrial fibrillation (P = .004; HR = 2.05), ventricular pacing mode (P = .025; HR = 1.69), use of antiarrhythmic drugs before pacemaker implant (P = .024; HR = 1.71), and age (P = .04; HR = 1.02). Actuarial incidence of stroke was 3% at 1 year, 5% at 5 years, and 13% at 10 years. Independent predictors for stroke were history of cerebrovascular disease (P < .001; HR = 5.22), ventricular pacing mode (P = .008; HR = 2.61), and history of paroxysmal atrial fibrillation (P = .037; HR = 2.81). CONCLUSIONS: Development of chronic atrial fibrillation and stroke in paced patients with sick sinus syndrome are strongly determined by clinical variables and secondarily by the pacing modality. Ventricular pacing mode predicts chronic atrial fibrillation in patients with preimplant paroxysmal atrial fibrillation but not in those without it.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1161/01.cir.88.3.1045

Cites

3 of 3 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Cited by

See all 203

Metadata

Authors
Sgarbossa, E. B., Pinski, S. L., Maloney, J. D., Simmons, T. W., Wilkoff, B. L., Castle, L. W., & Trohman, R. G.
Venue
Circulation
Published
1993-09
Volume
88
Issue
3
Pages
1045-1053
ISSN
  • 0009-7322 (ISSN-L)
  • 1524-4539
OpenAlex
W2066171379
Cited by
203
References
3
FWCI
4.98
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.