CoChat

Blood pressure modulation by central venous pressure and respiration. Buffering effects of the heart rate reflexes.

Open access
Triedman, J K, Saul, J P · 1994 · Circulation
Cited by 122

The DOI matches its Crossref record; 4 of the 4 references it cites were found in a registry or an index.

Abstract

BACKGROUND: Despite constant fluctuations in cardiac preload caused by the effects of respiration and changes in posture on venous return to the heart, arterial blood pressure remains remarkably constant. The effects of instantaneous lung volume (ILV) and variations of central venous pressure (CVP) on blood pressure (BP) were studied by use of frequency domain techniques to quantify the contribution of heart rate (HR) reflexes to attenuation of the effects of changes in right ventricular preload on arterial pressure. METHODS AND RESULTS: Random independent variation of ILV, then CVP (obtained using lower-body negative pressure), was performed in eight humans in the supine position. HR, ILV, CVP, and systolic (SBP) and diastolic (DBP) BPs were recorded during control periods and after complete blockade obtained by use of 0.04 mg/kg atropine and 0.2 mg/kg propranolol. A frequency-domain analysis was performed on pairwise relations by the cross-spectral technique. During autonomic blockade, fluctuations in CVP were induced up to 0.14 Hz but caused corresponding changes in arterial pressure only up to 0.08 Hz (P < .02), indicating a mechanical damping effect of the heart and pulmonary vasculature. Fluctuations of BP were also delayed from CVP by 1.55 to 2.10 seconds. At frequencies < 0.1 Hz, relations of CVP to all indices of BP increased with blockade (CVP-SBP, 0.9 +/- 0.5 versus 2.7 +/- 0.8 mm Hg/mm Hg, P < .01; CVP-DBP, 1.3 +/- 0.4 versus 4.3 +/- 1.4 mm Hg/mm Hg, P < .01; CVP-pulse pressure [PP], 1.0 +/- 0.3 versus 1.9 +/- 0.8 mm Hg/mm Hg, P < .05). Higher-frequency fluctuations of arterial BP were a relatively pure manifestation of respiratory activity. At frequencies from 0.15 to 0.35 Hz, the relation of ILV to SBP was unchanged with blockade, whereas relations of ILV to DBP and PP decreased (ILV-DBP, 6.1 +/- 3.5 versus 3.3 +/- 2.2 mm Hg/L, P < .02; ILV-PP, 7.0 +/- 4.3 versus 2.7 +/- 2.2 mm Hg/L, P < .01). An associated change in phase of these relations suggested that neurally mediated changes in HR may offset mechanical effects caused by respiration. CONCLUSIONS: Both slow changes of BP (< 0.08 Hz) induced by variations of CVP and more rapid changes induced by ILV are actively buffered by heart rate reflexes. During blockade, the mechanical properties of interposed cardiopulmonary structures limit CVP-induced fluctuations of BP. These findings have implications for BP regulation in pathological conditions associated with impairment of HR control.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1161/01.cir.89.1.169

Cites

4 of 4 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Cited by

See all 122

Metadata

Authors
Triedman, J. K., & Saul, J. P.
Venue
Circulation
Published
1994-01
Volume
89
Issue
1
Pages
169-179
ISSN
  • 0009-7322 (ISSN-L)
  • 1524-4539
OpenAlex
W2010731971
Cited by
122
References
4
FWCI
2.70
Type
journal article
Language
en
Open access
bronze

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.