CoChat

Circadian variation of sustained ventricular tachycardia in patients with coronary artery disease and implantable cardioverter-defibrillators.

Open access
Lampert, R, Rosenfeld, L, Batsford, W, Lee, F, McPherson, C · 1994 · Circulation
Cited by 144

The DOI matches its Crossref record; 8 of the 8 references it cites were found in a registry or an index.

Abstract

BACKGROUND: While previous studies using epidemiological data and ambulatory ECG monitoring have shown peak occurrence of sudden death and nonsustained ventricular tachycardia in the morning, none have examined circadian variation of potentially life-threatening ventricular tachycardia (VT), nor has any study observed circadian behavior of any arrhythmias in individuals followed longitudinally. We used the event memory of multiprogrammable implantable cardioverter-defibrillators to evaluate the circadian pattern of sustained VT over time. METHODS AND RESULTS: Data were reviewed from 32 consecutive patients with coronary artery disease and sustained VT who had received the Ventak PRX (CPI, Inc) cardioverter-defibrillator between May 1991 and August 1993 and had experienced at least one episode of VT terminated by their device. Mean follow-up was 14 +/- 7 months. Among the 2558 episodes recorded by the device logs, VT occurrence peaked between 6 AM and noon (P = .007 by ANOVA among four 6-hour time periods). Harmonic regression revealed a morning peak at 9 AM (P < .01). This morning peak occurred in patients with both frequent and infrequent events. Among 21 patients who experienced more than four VT events, 8 (38%) had an AM peak of VT occurrence (> 35% of VT between 6 AM and noon). Neither age, ejection fraction, event frequency, presenting arrhythmia, nor drug therapy distinguished patients who displayed the AM VT peak. CONCLUSIONS: In patients with coronary artery disease, sustained VT displays circadian variation with peak frequency in the morning, similar to that for sudden death. Individual patients who display specific patterns of circadian variation over time can be identified using defibrillator logs. Investigation of circadian variation of other phenomena to elucidate mechanisms of VT should focus on these patients.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1161/01.cir.90.1.241

Cites

8 of 8 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Cited by

See all 144

Metadata

Authors
Lampert, R., Rosenfeld, L., Batsford, W., Lee, F., & McPherson, C.
Venue
Circulation
Published
1994-07
Volume
90
Issue
1
Pages
241-247
ISSN
  • 0009-7322 (ISSN-L)
  • 1524-4539
OpenAlex
W2020388401
Cited by
144
References
8
FWCI
7.49
Type
journal article
Language
en
Open access
bronze

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.