CoChat

Heart rate variability as a prognostic tool in cardiology. A contribution to the problem from a theoretical point of view.

Open access
Moser, M, Lehofer, M, Sedminek, A, Lux, M, Zapotoczky, H G, Kenner, T, Noordergraaf, A · 1994 · Circulation
Cited by 118

The DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.

Abstract

BACKGROUND: Recent clinical studies have proposed standard deviation of heart rate as a diagnostic tool for the outcome of cardiac infarction. Mathematical analysis of heart rate variability shows that heart rate is influenced by different frequency components derived from different parts of the autonomous nervous system. In the experimental part of this study, we investigated the possibility of calculating a variable describing the parasympathetic branch of the autonomous nervous system exclusively. METHODS AND RESULTS: In 60 healthy volunteers, heart rate was measured to 1 millisecond during two different conditions: 5 minutes of rest, and 5 minutes of intermittent handgrip dynamometry; the latter is known to increase sympathetic arousal selectively. Heart rate was found to be lower at rest (65.9 +/- 9.7 beats per minute) than during dynamometry (72.8 +/- 10.4 beats per minute, P < .001). Respiratory sinus arrhythmia (RSA) calculated from the mean absolute differences between successive heart beats showed no significant change (3.01 +/- 1.62 beats per minute at rest versus 2.97 +/- 1.30 beats per minute during dynamometry). In contrast, standard deviation increased from 5.19 +/- 1.98 to 9.22 +/- 3.56 beats per minute (P < .001). CONCLUSIONS: It can be concluded from these data as well as from other plots presented in this article that RSA is a measure of the parasympathetic vagal tone, whereas standard deviation is increased by both sympathetic and parasympathetic arousal. Clinical evidence and data from physiological experiments are presented to show that a selective measure of vagal tone like RSA may offer advantages over standard deviation as a prognostic tool in cardiology.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1161/01.cir.90.2.1078

Cites

3 of 3 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 3 references

Cited by

Metadata

Authors
Moser, M., Lehofer, M., Sedminek, A., Lux, M., Zapotoczky, H. G., Kenner, T., & Noordergraaf, A.
Venue
Circulation
Published
1994-08
Volume
90
Issue
2
Pages
1078-1082
ISSN
  • 0009-7322 (ISSN-L)
  • 1524-4539
OpenAlex
W2006917635
Cited by
118
References
3
FWCI
3.00
Type
journal article
Language
en
Open access
bronze

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.