The DOI matches its Crossref record; 26 of the 26 references it cites were found in a registry or an index.
Marked Inflammatory Sequelae to Implantation of Biodegradable and Nonbiodegradable Polymers in Porcine Coronary Arteries
Open accessAbstract
Background With the thrombogenic tendency and permanent implant nature of metallic stents, synthetic polymers have been proposed as candidate materials for stents and local drug delivery designs. We investigated the biocompatibility of several synthetic polymers after experimental placement in the coronary artery. Methods and Results Five different biodegradable polymers (polyglycolic acid/polylactic acid [PGLA], polycaprolactone [PCL], polyhydroxybutyrate valerate [PHBV], polyorthoester [POE], and polyethyleneoxide/polybutylene terephthalate [PEO/PBTP]) and three nonbiodegradable polymers (polyurethane [PUR], silicone [SIL], and polyethylene terephthalate [PETP]) were tested as strips deployed longitudinally across 90° of the circumferential surface of coil wire stents. Appropriately sized polymer-loaded stents were implanted in porcine coronary arteries of 2.5- to 3.0-mm diameter. Four weeks after implantation, stent patency was assessed by angiography followed by microscopic examination of the coronary arteries. The biodegradable PCL, PHBV, and POE and the nonbiodegradable PUR and SIL evoked extensive inflammatory responses and fibrocellular proliferation (thickness of tissue response: 0.79±0.22, 1.12±0.01, 2.36±0.60, 1.24±0.36, and 1.43±0.15 mm, respectively). Less but still severe responses were observed for the biodegradable PGLA and PEO/PBTP (0.46±0.18 and 0.61±0.23 mm, respectively) and for the nonbiodegradable PETP (0.46±0.11 mm). Conclusions An array of both biodegradable and nonbiodegradable polymers has been demonstrated to induce a marked inflammatory reaction within the coronary artery with subsequent neointimal thickening, which was not expected on the basis of in vitro tests. The observed tissue response may be attributable to a combination of parent polymer compound, biodegradation products, and possibly implant geometry.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Serruys, P. W., de Jaegere, P., Kiemeneij, F., Macaya, C., Rutsch, W., Heyndrickx, G., Emanuelsson, H., Marco, J., Legrand, V., Materne, P., et al. (1994) · New England Journal of Medicine · doi:10.1056/nejm199408253310801 · Cited by 4,556
Self-citationFischman, D. L., Leon, M. B., Baim, D. S., Schatz, R. A., Savage, M. P., Penn, I., Detre, K., Veltri, L., Ricci, D., Nobuyoshi, M., et al. (1994) · New England Journal of Medicine · doi:10.1056/nejm199408253310802 · Cited by 4,271
Self-citation(1994) · New England Journal of Medicine · doi:10.1056/nejm199404073301402 · Cited by 2,589
Intracoronary Stenting Without Anticoagulation Accomplished With Intravascular Ultrasound Guidance
Colombo, A., Hall, P., Nakamura, S., Almagor, Y., Maiello, L., Martini, G., Gaglione, A., Goldberg, S. L., & Tobis, J. M. (1995) · Circulation · doi:10.1161/01.cir.91.6.1676 · Cited by 1,428
Topol, E., Califf, R., Weisman, H., Ellis, S., Tcheng, J., Worley, S., Ivanhoe, R., George, B., Fintel, D., Weston, M., et al. (1994) · The Lancet · doi:10.1016/s0140-6736(94)90007-8 · Cited by 838
Self-citationBiodegradable polymers as drug delivery systems
(1992) · Comparative Biochemistry and Physiology Part A: Physiology · doi:10.1016/0300-9629(92)90663-b · Cited by 779
Miller, R. A., Brady, J. M., & Cutright, D. E. (1977) · Journal of Biomedical Materials Research · doi:10.1002/jbm.820110507 · Cited by 722
Frazza, E. J., & Schmitt, E. E. (1971) · Journal of Biomedical Materials Research · doi:10.1002/jbm.820050207 · Cited by 572
Endovascular Stent Design Dictates Experimental Restenosis and Thrombosis
Rogers, C., & Edelman, E. R. (1995) · Circulation · doi:10.1161/01.cir.91.12.2995 · Cited by 543
Absorbable implants for the fixation of fractures.
Böstman, O. M. (1991) · The Journal of Bone & Joint Surgery · doi:10.2106/00004623-199173010-00022 · Cited by 459
The intracellular degradation of poly(ε‐caprolactone)
Woodward, S. C., Brewer, P. S., Moatamed, F., Schindler, A., & Pitt, C. G. (1985) · Journal of Biomedical Materials Research · doi:10.1002/jbm.820190408 · Cited by 380
Miller, N. D., & Williams, D. F. (1987) · Biomaterials · doi:10.1016/0142-9612(87)90102-5 · Cited by 254
Bio‐Compatibility in selection of materials for implantation
Homsy, C. A. (1970) · Journal of Biomedical Materials Research · doi:10.1002/jbm.820040306 · Cited by 239
Hårdhammar, P. A., van Beusekom, H. M. M., Emanuelsson, H. U., Hofma, S. H., Albertsson, P. A., Verdouw, P. D., Boersma, E., Serruys, P. W., & van der Giessen, W. J. (1996) · Circulation · doi:10.1161/01.cir.93.3.423 · Cited by 187
Self-citationMurphy, J. G., Schwartz, R. S., Edwards, W. D., Camrud, A. R., Vlietstra, R. E., & Holmes, D. R. (1992) · Circulation · doi:10.1161/01.cir.86.5.1596 · Cited by 145
Self-citationBiomaterials—The Interfacial Problem
Hench, L. L., & Ethridge, E. C. (1975) · Elsevier eBooks · doi:10.1016/b978-0-12-004905-9.50007-4 · Cited by 114
Compliance as a factor effecting the patency of a copolyurethane vascular graft
Lyman, D. J., Fazzio, F. J., Voorhees, H., Robinson, G., & Albo, D. (1978) · Journal of Biomedical Materials Research · doi:10.1002/jbm.820120307 · Cited by 94
Effect of implantation site on phagocyte/polymer interaction and fibrous capsule formation
Bakker, D., van Blitterswijk, C., Hesseling, S. C., Grote, J. J., & Daems, W. (1988) · Biomaterials · doi:10.1016/0142-9612(88)90064-6 · Cited by 86
Bakker, D., van Blitterswijk, C., Hesseling, S. C., Koerten, H. K., Kuijpers, W., & Grote, J. J. (1990) · Journal of Biomedical Materials Research · doi:10.1002/jbm.820240407 · Cited by 73
Rosilio, V., Benoît, J., Deyme, M., Thies, C., & Madelmont, G. (1991) · Journal of Biomedical Materials Research · doi:10.1002/jbm.820250509 · Cited by 46
Biocompatibility of six elastomers in vitro
Bakker, D., van Blitterswijk, C., Daems, W., & Grote, J. J. (1988) · Journal of Biomedical Materials Research · doi:10.1002/jbm.820220506 · Cited by 42
Coronary stenting with polymer-coated and uncoated self-expanding endoprostheses in pigs
van der Giessen, W. J., van Beusekom, H. M. M., van Houten, C. D., van Woerkens, L. J., Verdouw, P. D., & Serruys, P. W. J. C. (1992) · Coronary Artery Disease · doi:10.1097/00019501-199207000-00014 · Cited by 36
Self-citationMechanical Properties of Arteries and Arterial Grafts
How, T. V. (1992) · Springer eBooks · doi:10.1007/978-1-4471-1847-3_1 · Cited by 29
Polymeric Materials and Artificial Organs
Gebelein, C. G. (1984) · ACS symposium series · doi:10.1021/bk-1984-0256 · Cited by 28
Chegini, N., Hay, D. L., von Fraunhofer, J. A., & Masterson, B. J. (1988) · Journal of Biomedical Materials Research · doi:10.1002/jbm.820220108 · Cited by 26
Medical Applications of Implantable Polyurethanes: Current Issues
Coury, A. J., Slaikeu, P. C., Cahalan, P. T., & Stokes, K. B. (1987) · Progress in Rubber and Plastics Technology · doi:10.1177/147776068700300403 · Cited by 13
Cited by
Virmani, R., Guagliumi, G., Farb, A., Musumeci, G., Grieco, N., Motta, T., Mihalcsik, L., Tespili, M., Valsecchi, O., & Kolodgie, F. D. (2004) · Circulation · doi:10.1161/01.cir.0000116202.41966.d4 · Cited by 1,469
Coronary stents: A materials perspective
Mani, G., Feldman, M. D., Patel, D., & Agrawal, C. M. (2007) · Biomaterials · doi:10.1016/j.biomaterials.2006.11.042 · Cited by 866
Kornowski, R., Hong, M. K., Tio, F. O., Bramwell, O., Wu, H., & Leon, M. B. (1998) · Journal of the American College of Cardiology · doi:10.1016/s0735-1097(97)00450-6 · Cited by 844
Camenzind, E., Steg, P. G., & Wijns, W. (2007) · Circulation · doi:10.1161/circulationaha.106.666800 · Cited by 818
Newby, A. C. (2005) · Physiological Reviews · doi:10.1152/physrev.00048.2003 · Cited by 817
Metadata
- Authors
- van der Giessen, W. J., Lincoff, A. M., Schwartz, R. S., van Beusekom, H. M. M., Serruys, P. W., Holmes, D. R., Ellis, S. G., & Topol, E. J.
- Venue
- Circulation
- Published
- 1996-10
- Volume
- 94
- Issue
- 7
- Pages
- 1690-1697
- ISSN
- 0009-7322 (ISSN-L)
- 1524-4539
- OpenAlex
- W2081554071
- Cited by
- 852
- References
- 26
- FWCI
- 14.59
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.