The DOI matches its Crossref record; 6 of the 6 references it cites were found in a registry or an index.
Comparison Between Noninvasive Indices of Baroreceptor Sensitivity and the Phenylephrine Method in Post–Myocardial Infarction Patients
Abstract
Background—Depressed baroreflex sensitivity obtained by means of a phenylephrine test plays a prognostic role in patients with a previous myocardial infarction. Our purpose was to evaluate the correlation and agreement between the baroreflex sensitivity obtained with phenylephrine and that obtained by two noninvasive methods: the α-index and sequence analysis. Methods and Results—The α-index was measured by means of the spectral analysis of RR and systolic blood pressure variabilities in both the high- and low-frequency bands; sequences were identified from simultaneously recorded time series in which the RR and systolic blood pressure concurrently increased or decreased. Noninvasive baroreflex sensitivity tests were performed during both spontaneous and controlled respiration. Fifty-two consecutive patients with recent myocardial infarction underwent the analyses. Although the correlations between phenylephrine and either of the noninvasive methods were always significant, those found during controlled respiration had the highest r values (r=.70). However, the limits of agreement calculated by means of the Bland and Altman method were wide for both noninvasive methods. Conclusions—The results obtained by means of noninvasive baroreflex sensitivity assessments should not be used in clinical practice as an alternative to those obtained by the phenylephrine method.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT
Martin Bland, J., & Altman, D. (1986) · The Lancet · doi:10.1016/s0140-6736(86)90837-8 · Cited by 47,965
Heart rate variability: Standards of measurement, physiological interpretation, and clinical use
Malik, M., Bigger, J. T., Camm, A. J., Kleiger, R. E., Malliani, A., Moss, A. J., & Schwartz, P. J. (1996) · European Heart Journal · doi:10.1093/oxfordjournals.eurheartj.a014868 · Cited by 15,289
Pagani, M., Lombardi, F., Guzzetti, S., Rimoldi, O., Furlan, R., Pizzinelli, P., Sandrone, G., Malfatto, G., Dell'Orto, S., & Piccaluga, E. (1986) · Circulation Research · doi:10.1161/01.res.59.2.178 · Cited by 4,130
Self-citationParati, G., Casadei, R., Groppelli, A., Di Rienzo, M., & Mancia, G. (1989) · Hypertension · doi:10.1161/01.hyp.13.6.647 · Cited by 899
Parati, G., Saul, J. P., Di Rienzo, M., & Mancia, G. (1995) · Hypertension · doi:10.1161/01.hyp.25.6.1276 · Cited by 849
Respiratory sinus arrhythmia in the denervated human heart
Bernardi, L., Keller, F., Sanders, M., Reddy, P. S., Griffith, B., Meno, F., & Pinsky, M. R. (1989) · Journal of Applied Physiology · doi:10.1152/jappl.1989.67.4.1447 · Cited by 272
Cited by
Baroreflex Sensitivity: Measurement and Clinical Implications
La Rovere, M. T., Pinna, G. D., & Raczak, G. (2008) · Annals of Noninvasive Electrocardiology · doi:10.1111/j.1542-474x.2008.00219.x · Cited by 659
How to measure baroreflex sensitivity: from the cardiovascular laboratory to daily life
Parati, G., Di Rienzo, M., & Mancia, G. (2000) · Journal of Hypertension · doi:10.1097/00004872-200018010-00003 · Cited by 516
Parati, G., Mancia, G., Rienzo, M. D., & Castiglioni, P. (2006) · Journal of Applied Physiology · doi:10.1152/japplphysiol.00446.2006 · Cited by 325
Human sympathetic and vagal baroreflex responses to sequential nitroprusside and phenylephrine
Rudas, L., Crossman, A. A., Morillo, C. A., Halliwill, J. R., Tahvanainen, K. U. O., Kuusela, T. A., & Eckberg, D. L. (1999) · American Journal of Physiology-Heart and Circulatory Physiology · doi:10.1152/ajpheart.1999.276.5.h1691 · Cited by 294
Guzik, P., Piskorski, J., Krauze, T., Schneider, R., Wesseling, K. H., Wykretowicz, A., & Wysocki, H. (2007) · The Journal of Physiological Sciences · doi:10.2170/physiolsci.rp005506 · Cited by 232
Metadata
- Authors
- Pitzalis, M. V., Mastropasqua, F., Passantino, A., Massari, F., Ligurgo, L., Forleo, C., Balducci, C., Lombardi, F., & Rizzon, P.
- Venue
- Circulation
- Published
- 1998-04-14
- Volume
- 97
- Issue
- 14
- Pages
- 1362-1367
- ISSN
- 0009-7322 (ISSN-L)
- 1524-4539
- OpenAlex
- W1965987399
- Cited by
- 179
- References
- 6
- FWCI
- 10.39
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.