Risk to Patients From Radiation Associated With Radiofrequency Ablation for Supraventricular Tachycardia
Open accessThe DOI matches its Crossref record; 18 of the 18 references it cites were found in a registry or an index.
Abstract
Background —Radiofrequency ablation may be associated with prolonged fluoroscopy times. Previous studies have calculated radiation risks by measuring the radiation dose at a limited number (6) of body sites. This is an inherently inaccurate measure. Our study aimed to quantify more precisely patient-related radiation risks associated with radiofrequency ablation for supraventricular tachycardia. Methods and Results —Nine female patients having radiofrequency ablation for supraventricular tachycardia were studied. The radiation dose was determined at 41 body sites in each patient with the use of thermoluminescent dosimeters and was correlated with that measured simultaneously with a Diamentor dose-area product meter. The estimated mean organ doses (mGy) per 60 minutes of fluoroscopy were: lungs 30.8; bone marrow 4.3; left breast 5.1; right breast 3.5; and thyroid 2.4. From the average organ doses, the estimated mean total lifetime excess risk of a fatal malignancy was 294 per million cases (0.03%) per 60 minutes of fluoroscopy. The risk calculation from the Diamentor dose-area product and thermoluminescent dosimeters were similar, suggesting that radiation dose was measured accurately. The estimated risk of radiation-induced malignancy increased with increasing body mass index ( P =0.03). Conclusions —Prolonged fluoroscopy during radiofrequency ablation may potentially cause a small increase in the lifetime risk of fatal malignancy, with lung malignancy being most likely. This risk is small only with the use of techniques and x-ray equipment optimized to keep radiation as low as possible. The risk is increased in obese patients.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Recommendations of the International Commission on Radiological Protection
(1961) · Postgraduate Medical Journal · doi:10.1136/pgmj.37.425.168-b · Cited by 5,862
The Cardiac Arrhythmia Suppression Trial (CAST) Investigators (1989) · New England Journal of Medicine · doi:10.1056/nejm198908103210629 · Cited by 3,300
Recommendations of the International Commission on Radiological Protection
(1959) · Health Physics · doi:10.1097/00004032-195901000-00001 · Cited by 1,703
Jackman, W. M., Wang, X., Friday, K. J., Roman, C. A., Moulton, K. P., Beckman, K. J., McClelland, J. H., Twidale, N., Hazlitt, H. A., Prior, M. I., et al. (1991) · New England Journal of Medicine · doi:10.1056/nejm199106063242301 · Cited by 1,422
Sources, Effects and Risks of Ionizing Radiation
Kohn, H. I. (1989) · Radiation Research · doi:10.2307/3577647 · Cited by 1,292
Jackman, W. M., Beckman, K. J., McClelland, J. H., Wang, X., Friday, K. J., Roman, C. A., Moulton, K. P., Twidale, N., Hazlitt, H. A., Prior, M. I., et al. (1992) · New England Journal of Medicine · doi:10.1056/nejm199207303270504 · Cited by 1,160
Weir, M. (1990) · Cardiopulmonary Physical Therapy Journal · doi:10.1097/01823246-199001020-00009 · Cited by 1,058
Calkins, H., Langberg, J., Sousa, J., el-Atassi, R., Leon, A., Kou, W., Kalbfleisch, S., & Morady, F. (1992) · Circulation · doi:10.1161/01.cir.85.4.1337 · Cited by 399 · cited 3×
“However, prolonged fluoroscopy use is still likely in complex cases with multiple pathways.(4) Operators should ensure that high-output fluoroscopy units are not used for procedures such as radiofrequency ablation, in which prolonged fluoroscopy usage might occur.”
BackgroundMethodInfluentialHealth Effects of Exposure to Low Levels of Ionizing Radiation (BEIR V)
Kohn, H. I. (1990) · Radiation Research · doi:10.2307/3577873 · Cited by 376
Calkins, H., Niklason, L., Sousa, J., el-Atassi, R., Langberg, J., & Morady, F. (1991) · Circulation · doi:10.1161/01.cir.84.6.2376 · Cited by 238 · cited 3×
“Reliability of Measuring Radiation to Breasts With Single Thermoluminescent Dosimeter Over the Xiphisternum Other studies that have assessed radiation to patients associated with cardiac catheterization have used one TLD over the xiphisternum to determine the radiation to the breasts.(7,22) In our study, we assessed t…”
BackgroundMethod
Cited by
Calkins, H., Hindricks, G., Cappato, R., Kim, Y.-H., Saad, E. B., Aguinaga, L., Akar, J. G., Badhwar, V., Brugada, J., Camm, J., et al. (2017) · Heart Rhythm · doi:10.1016/j.hrthm.2017.05.012 · Cited by 2,755
Calkins, H., Kuck, K. H., Cappato, R., Brugada, J., Camm, A. J., Chen, S.-A., Crijns, H. J. G., Damiano, R. J., Davies, D. W., DiMarco, J., et al. (2012) · Europace · doi:10.1093/europace/eus027 · Cited by 2,722
Calkins, H., Brugada, J., Packer, D. L., Cappato, R., Chen, S.-A., Crijns, H. J. G., Damiano, R. J., Davies, D. W., Haines, D. E., Haissaguerre, M., et al. (2007) · Heart Rhythm · doi:10.1016/j.hrthm.2007.04.005 · Cited by 1,701
Calkins, H., Kuck, K. H., Cappato, R., Brugada, J., Camm, A. J., Chen, S.-A., Crijns, H. J. G., Damiano, R. J., Davies, D. W., DiMarco, J., et al. (2012) · Journal of Interventional Cardiac Electrophysiology · doi:10.1007/s10840-012-9672-7 · Cited by 1,675
Calkins, H., Kuck, K. H., Cappato, R., Brugada, J., Camm, A. J., Chen, S.-A., Crijns, H. J. G., Damiano, R. J., Davies, D. W., DiMarco, J., et al. (2012) · Heart Rhythm · doi:10.1016/j.hrthm.2011.12.016 · Cited by 1,456
Calkins, H., Brugada, J., Packer, D. L., Cappato, R., Chen, S.-A., Crijns, H. J. G., Damiano, R. J., Davies, D. W., Haines, D. E., Haissaguerre, M., et al. (2007) · Europace · doi:10.1093/europace/eum120 · Cited by 1,290
Calkins, H., Hindricks, G., Cappato, R., Kim, Y.-H., Saad, E. B., Aguinaga, L., Akar, J. G., Badhwar, V., Brugada, J., Camm, J., et al. (2018) · EP Europace · doi:10.1093/europace/eux274 · Cited by 1,164
Calkins, H., Hindricks, G., Cappato, R., Kim, Y., Saad, E. B., Aguinaga, L., Akar, J. G., Badhwar, V., Brugada, J., Camm, J., et al. (2017) · Journal of Arrhythmia · doi:10.1016/j.joa.2017.08.001 · Cited by 707
Calkins, H., Hindricks, G., Cappato, R., Kim, Y.-H., Saad, E. B., Aguinaga, L., Akar, J. G., Badhwar, V., Brugada, J., Camm, J., et al. (2018) · EP Europace · doi:10.1093/europace/eux275 · Cited by 509
Venice Chart International Consensus Document on Atrial Fibrillation Ablation
NATALE, A., RAVIELE, A., ARENTZ, T., CALKINS, H., CHEN, S., HAÏSSAGUERRE, M., HINDRICKS, G., HO, Y., KUCK, K. H., MARCHLINSKI, F., et al. (2007) · Journal of Cardiovascular Electrophysiology · doi:10.1111/j.1540-8167.2007.00816.x · Cited by 406
Kirchhof, P., Auricchio, A., Bax, J., Crijns, H., Camm, J., Diener, H.-C., Goette, A., Hindricks, G., Hohnloser, S., Kappenberger, L., et al. (2007) · European Heart Journal · doi:10.1093/eurheartj/ehm358 · Cited by 380
Venneri, L., Rossi, F., Botto, N., Andreassi, M. G., Salcone, N., Emad, A., Lazzeri, M., Gori, C., Vano, E., & Picano, E. (2009) · American Heart Journal · doi:10.1016/j.ahj.2008.08.009 · Cited by 360
Cardiac catheterisation guided by MRI in children and adults with congenital heart disease
Razavi, R., Hill, D. L., Keevil, S. F., Miquel, M. E., Muthurangu, V., Hegde, S., Rhode, K., Barnett, M., van Vaals, J., Hawkes, D. J., et al. (2003) · The Lancet · doi:10.1016/s0140-6736(03)14956-2 · Cited by 336
Heidbuchel, H., Wittkampf, F. H. M., Vano, E., Ernst, S., Schilling, R., Picano, E., Mont, L., ESC Scientific Document Group, Jais, P., de Bono, J., et al. (2014) · EP Europace · doi:10.1093/europace/eut409 · Cited by 311
Kirchhof, P., Auricchio, A., Bax, J., Crijns, H., Camm, J., Diener, H.-C., Goette, A., Hindricks, G., Hohnloser, S., Kappenberger, L., et al. (2007) · Europace · doi:10.1093/europace/eum191 · Cited by 293
Radiation Exposure During Catheter Ablation of Atrial Fibrillation
Lickfett, L., Mahesh, M., Vasamreddy, C., Bradley, D., Jayam, V., Eldadah, Z., Dickfeld, T., Kearney, D., Dalal, D., Lüderitz, B., et al. (2004) · Circulation · doi:10.1161/01.cir.0000146952.49223.11 · Cited by 236
Earley, M. J., Showkathali, R., Alzetani, M., Kistler, P. M., Gupta, D., Abrams, D. J., Horrocks, J. A., Harris, S. J., Sporton, S. C., & Schilling, R. J. (2006) · European Heart Journal · doi:10.1093/eurheartj/ehi834 · Cited by 201
“X-ray during catheter ablation is associated with an increased lifetime risk of malignancy and all possible measures should be taken to minimize exposure.(1,2) Nonfluoroscopic mapping technology has been of great value in the ablation of complex arrhythmias such as atrial fibrillation, atypical atrial flutter, and ven…”
BackgroundPerisinakis, K., Damilakis, J., Theocharopoulos, N., Manios, E., Vardas, P., & Gourtsoyiannis, N. (2001) · Circulation · doi:10.1161/hc2601.091710 · Cited by 176
Metadata
- Authors
- Kovoor, P., Ricciardello, M., Collins, L., Uther, J. B., & Ross, D. L.
- Venue
- Circulation
- Published
- 1998-10-13
- Volume
- 98
- Issue
- 15
- Pages
- 1534-1540
- ISSN
- 0009-7322 (ISSN-L)
- 1524-4539
- OpenAlex
- W1970596377
- Cited by
- 184
- References
- 18
- FWCI
- 3.64
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.