Randomized Multicenter Comparison of Conventional Anticoagulation Versus Antiplatelet Therapy in Unplanned and Elective Coronary Stenting: The Full Anticoagulation Versus Aspirin and Ticlopidine (FANTASTIC) Study
Open accessThe DOI matches its Crossref record; 8 of the 8 references it cites were found in a registry or an index.
Abstract
Background —Dual therapy with ticlopidine and aspirin has been shown to be as effective as or more effective than conventional anticoagulation in patients with an optimal result after implantation of intracoronary metallic stents. However, the safety and efficacy of antiplatelet therapy alone in an unselected population has not been evaluated. Methods —Patients were randomized to conventional anticoagulation or to treatment with antiplatelet therapy alone. Indications for stenting were classified as elective (decided before the procedure) or unplanned (to salvage failed angioplasty or to optimize the results of balloon angioplasty). After stenting, patients received aspirin and either ticlopidine or conventional anticoagulation (heparin or oral anticoagulant). The primary end point was the occurrence of bleeding or peripheral vascular complications; secondary end points were cardiac events (death, infarction, or stent occlusion) and duration of hospitalization. Results —In 13 centers, 236 patients were randomized to anticoagulation and 249 to antiplatelet therapy. Stenting was elective in 58% of patients and unplanned in 42%. Stent implantation was successfully achieved in 99% of patients. A primary end point occurred in 33 patients (13.5%) in the antiplatelet group and 48 patients (21%) in the anticoagulation group (odds ratio=0.6 [95% CI 0.36 to 0.98], P =0.03). Major cardiac-related events in electively stented patients were less common (odds ratio=0.23 [95% CI 0.05 to 0.91], P =0.01) in the antiplatelet group (3 of 123, 2.4%) than the anticoagulation group (11 of 111, 9.9%). Hospital stay was significantly shorter in the antiplatelet group (4.3±3.6 versus 6.4±3.7 days, P =0.0001). Conclusions —Antiplatelet therapy after coronary stenting significantly reduced rates of bleeding and subacute stent occlusion compared with conventional anticoagulation.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Serruys, P. W., de Jaegere, P., Kiemeneij, F., Macaya, C., Rutsch, W., Heyndrickx, G., Emanuelsson, H., Marco, J., Legrand, V., Materne, P., et al. (1994) · New England Journal of Medicine · doi:10.1056/nejm199408253310801 · Cited by 4,556
Self-citationFischman, D. L., Leon, M. B., Baim, D. S., Schatz, R. A., Savage, M. P., Penn, I., Detre, K., Veltri, L., Ricci, D., Nobuyoshi, M., et al. (1994) · New England Journal of Medicine · doi:10.1056/nejm199408253310802 · Cited by 4,271
Ryan, T. J., Faxon, D. P., Gunnar, R. M., Kennedy, J. W., King, S. B., Loop, F. D., Peterson, K. L., Reeves, T. J., Williams, D. O., & Winters, W. L. (1988) · Circulation · doi:10.1161/01.cir.78.2.486 · Cited by 2,123
Schömig, A., Neumann, F.-J., Kastrati, A., Schühlen, H., Blasini, R., Hadamitzky, M., Walter, H., Zitzmann-Roth, E.-M., Richardt, G., Alt, E., et al. (1996) · New England Journal of Medicine · doi:10.1056/nejm199604253341702 · Cited by 2,028
Intracoronary Stenting Without Anticoagulation Accomplished With Intravascular Ultrasound Guidance
Colombo, A., Hall, P., Nakamura, S., Almagor, Y., Maiello, L., Martini, G., Gaglione, A., Goldberg, S. L., & Tobis, J. M. (1995) · Circulation · doi:10.1161/01.cir.91.6.1676 · Cited by 1,428
Ryan, T. J., Bauman, W. B., Kennedy, J. W., Kereiakes, D. J., King, S. B., McCallister, B. D., Smith, S. C., & Ullyot, D. J. (1993) · Circulation · doi:10.1161/01.cir.88.6.2987 · Cited by 399
Hall, P., Nakamura, S., Maiello, L., Itoh, A., Blengino, S., Martini, G., Ferraro, M., & Colombo, A. (1996) · Circulation · doi:10.1161/01.cir.93.2.215 · Cited by 281
Gregorini, L., Marco, J., Fajadet, J. C., Bernies, M., Cassagneau, B. G., Brunel, P., Bossi, I. M., & Mannucci, P. M. (1997) · Journal of the American College of Cardiology · doi:10.1016/s0735-1097(96)00428-7 · Cited by 110
Cited by
Steinhubl, S. R., Berger, P. B., Mann III, J. T., Fry, E. T. A., DeLago, A., Wilmer, C., Topol, E. J., & for the CREDO Investigators (2002) · JAMA · doi:10.1001/jama.288.19.2411 · Cited by 3,078
Valgimigli, M., Bueno, H., Byrne, R. A., Collet, J.-P., Costa, F., Jeppsson, A., Jüni, P., Kastrati, A., Kolh, P., Mauri, L., et al. (2018) · European Heart Journal · doi:10.1093/eurheartj/ehx419 · Cited by 2,987
Self-citationGuidelines for Percutaneous Coronary Interventions
Silber, S., Albertsson, P., Avilés, F. F., Camici, P. G., Colombo, A., Hamm, C., Jørgensen, E., Marco, J., Nordrehaug, J.-E., Ruzyllo, W., et al. (2005) · European Heart Journal · doi:10.1093/eurheartj/ehi138 · Cited by 1,609
Price, M. J. (2011) · JAMA · doi:10.1001/jama.2011.290 · Cited by 1,308
Antithrombotic therapy after acute coronary syndrome or PCI in atrial fibrillation
Lopes, R. D., Heizer, G., Aronson, R., Vora, A. N., Massaro, T., Mehran, R., Goodman, S. G., Windecker, S., Darius, H., Li, J., et al. (2019) · New England Journal of Medicine · doi:10.1056/nejmoa1817083 · Cited by 1,228
Platelet Glycoprotein IIb/IIIa Inhibition with Coronary Stenting for Acute Myocardial Infarction
Montalescot, G., Barragan, P., Wittenberg, O., Ecollan, P., Elhadad, S., Villain, P., Boulenc, J.-M., Morice, M.-C., Maillard, L., Pansiéri, M., et al. (2001) · New England Journal of Medicine · doi:10.1056/nejm200106213442503 · Cited by 1,186
Grines, C. L., Bonow, R. O., Casey, D. E., Gardner, T. J., Lockhart, P. B., Moliterno, D. J., O’Gara, P., & Whitlow, P. (2007) · Circulation · doi:10.1161/circulationaha.106.180944 · Cited by 1,140
Montalescot, G., Wiviott, S. D., Braunwald, E., Murphy, S. A., Gibson, C. M., McCabe, C. H., & Antman, E. M. (2009) · The Lancet · doi:10.1016/s0140-6736(09)60441-4 · Cited by 1,068
Bertrand, M. E., Rupprecht, H.-J., Urban, P., Gershlick, A. H., & Investigators, F. T. C. (2000) · Circulation · doi:10.1161/01.cir.102.6.624 · Cited by 1,010
Self-citationVariability in Individual Responsiveness to Clopidogrel
Angiolillo, D. J., Fernandez-Ortiz, A., Bernardo, E., Alfonso, F., Macaya, C., Bass, T. A., & Costa, M. A. (2007) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2006.11.044 · Cited by 959
Stent Thrombosis in the Modern Era: A Pooled Analysis of Multicenter Coronary Stent Clinical Trials
Cutlip, D. E., Baim, D. S., Ho, K. K. L., Popma, J. J., Lansky, A. J., Cohen, D. J., Carrozza, J. P., Chauhan, M. S., Rodriguez, O., & Kuntz, R. E. (2001) · Circulation · doi:10.1161/01.cir.103.15.1967 · Cited by 855
Camenzind, E., Steg, P. G., & Wijns, W. (2007) · Circulation · doi:10.1161/circulationaha.106.666800 · Cited by 818
Catastrophic outcomes of noncardiac surgery soon after coronary stenting
Kałuza, G. L., Joseph, J., Lee, J. R., Raizner, M. E., & Raizner, A. E. (2000) · Journal of the American College of Cardiology · doi:10.1016/s0735-1097(00)00521-0 · Cited by 723
Price, M. J., Endemann, S., Gollapudi, R. R., Valencia, R., Stinis, C. T., Levisay, J. P., Ernst, A., Sawhney, N. S., Schatz, R. A., & Teirstein, P. S. (2008) · European Heart Journal · doi:10.1093/eurheartj/ehn046 · Cited by 651
Brandt, J. T., Payne, C. D., Wiviott, S. D., Weerakkody, G., Farid, N. A., Small, D. S., Jakubowski, J. A., Naganuma, H., & Winters, K. J. (2007) · American Heart Journal · doi:10.1016/j.ahj.2006.10.010 · Cited by 571
Quinn, M. J., & Fitzgerald, D. J. (1999) · Circulation · doi:10.1161/01.cir.100.15.1667 · Cited by 496
Wiviott, S. D., Braunwald, E., McCabe, C. H., Horvath, I., Keltai, M., Herrman, J.-P. R., Van de Werf, F., Downey, W. E., Scirica, B. M., Murphy, S. A., et al. (2008) · The Lancet · doi:10.1016/s0140-6736(08)60422-5 · Cited by 453
Dzau, V. J., Antman, E. M., Black, H. R., Hayes, D. L., Manson, J. E., Plutzky, J., Popma, J. J., & Stevenson, W. (2006) · Circulation · doi:10.1161/circulationaha.106.655688 · Cited by 437
Bertrand, M. (2000) · European Heart Journal · doi:10.1053/euhj.2000.2301 · Cited by 410
Self-citationValgimigli, M., Bueno, H., Byrne, R. A., Collet, J.-P., Costa, F., Jeppsson, A., Jüni, P., Kastrati, A., Kolh, P., Mauri, L., et al. (2018) · European Journal of Cardio-Thoracic Surgery · doi:10.1093/ejcts/ezx334 · Cited by 409
Scientific and therapeutic advances in antiplatelet therapy
Bhatt, D. L., & Topol, E. J. (2003) · Nature Reviews Drug Discovery · doi:10.1038/nrd985 · Cited by 407
Grines, C. L., Bonow, R. O., Casey, D. E., Gardner, T. J., Lockhart, P. B., Moliterno, D. J., O'Gara, P., & Whitlow, P. (2007) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2007.01.003 · Cited by 404
Wiviott, S. D., Antman, E. M., Winters, K. J., Weerakkody, G., Murphy, S. A., Behounek, B. D., Carney, R. J., Lazzam, C., McKay, R. G., McCabe, C. H., et al. (2005) · Circulation · doi:10.1161/circulationaha.104.502815 · Cited by 381
Husted, S., Wallentin, L., Andreotti, F., Arnesen, H., Bachmann, F., Baigent, C., Huber, K., Jespersen, J., Kristensen, S. D., Lip, G. Y. H., et al. (2013) · Thrombosis and Haemostasis · doi:10.1160/th13-06-0443 · Cited by 365
Husted, S., Wallentin, L., Andreotti, F., Arnesen, H., Bachmann, F., Baigent, C., Huber, K., Jespersen, J., Kristensen, S., Lip, G. Y. H., et al. (2013) · Thrombosis and Haemostasis · doi:10.1160/th12-06-0403 · Cited by 364
Novel antiplatelet agents in acute coronary syndrome
Franchi, F., & Angiolillo, D. J. (2015) · Nature Reviews Cardiology · doi:10.1038/nrcardio.2014.156 · Cited by 353
Clinical Aspects of Platelet Inhibitors and Thrombus Formation
Meadows, T. A., & Bhatt, D. L. (2007) · Circulation Research · doi:10.1161/01.res.0000264509.36234.51 · Cited by 351
Hongo, R. H., Ley, J., Dick, S. E., & Yee, R. R. (2002) · Journal of the American College of Cardiology · doi:10.1016/s0735-1097(02)01954-x · Cited by 336
Rothberg, M. B., Celestin, C., Fiore, L. D., Lawler, E., & Cook, J. R. (2005) · Annals of Internal Medicine · doi:10.7326/0003-4819-143-4-200508160-00005 · Cited by 334
Heparin coatings for improving blood compatibility of medical devices
Biran, R., & Pond, D. (2017) · Advanced Drug Delivery Reviews · doi:10.1016/j.addr.2016.12.002 · Cited by 334
Diabetes and Antiplatelet Therapy in Acute Coronary Syndrome
Ferreiro, J. L., & Angiolillo, D. J. (2011) · Circulation · doi:10.1161/circulationaha.109.913376 · Cited by 333
Topol, E. J., Mark, D. B., Lincoff, A. M., Cohen, E., Burton, J., Kleiman, N., Talley, D., Sapp, S., Booth, J., Cabot, C. F., et al. (1999) · The Lancet · doi:10.1016/s0140-6736(99)10018-7 · Cited by 324
Urban, P., Gershlick, A. H., Guagliumi, G., Guyon, P., Lotan, C., Schofer, J., Seth, A., Sousa, J. E., Wijns, W., Berge, C., et al. (2006) · Circulation · doi:10.1161/circulationaha.104.532242 · Cited by 322
Hongo, R. H., Ley, J., Dick, S. E., & Yee, R. R. (2002) · ACC Current Journal Review · doi:10.1016/s1062-1458(02)00966-2 · Cited by 315
Huber, K., Andreotti, F., Arnesen, H., Airaksinen, K. J., Cuisset, T., Kirchhof, P., Marín, F., & Lip, G. (2010) · Thrombosis and Haemostasis · doi:10.1160/th09-08-0580 · Cited by 303
Safety and efficacy of combined antiplatelet-warfarin therapy after coronary stenting
Karjalainen, P. P., Porela, P., Ylitalo, A., Vikman, S., Nyman, K., Vaittinen, M.-A., Airaksinen, T. J., Niemela, M., Vahlberg, T., & Airaksinen, K. E. J. (2007) · European Heart Journal · doi:10.1093/eurheartj/ehl488 · Cited by 286
Mega, J. L., & Simon, T. (2015) · The Lancet · doi:10.1016/s0140-6736(15)60243-4 · Cited by 284
Superiority of Clopidogrel Versus Aspirin in Patients With Prior Cardiac Surgery
Bhatt, D. L., Chew, D. P., Hirsch, A. T., Ringleb, P. A., Hacke, W., & Topol, E. J. (2001) · Circulation · doi:10.1161/01.cir.103.3.363 · Cited by 282
Ruiz-Nodar, J. M., Marín, F., Hurtado, J. A., Valencia, J., Pinar, E., Pineda, J., Gimeno, J. R., Sogorb, F., Valdés, M., & Lip, G. Y. H. (2008) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2007.11.035 · Cited by 269
Cadroy, Y., Bossavy, J.-P., Thalamas, C., Sagnard, L., Sakariassen, K., & Boneu, B. (2000) · Circulation · doi:10.1161/01.cir.101.24.2823 · Cited by 266
Metadata
- Authors
- Bertrand, M. E., Legrand, V., Boland, J., Fleck, E., Bonnier, J., Emmanuelson, H., Vrolix, M., Missault, L., Chierchia, S., Casaccia, M., Niccoli, L., Oto, A., White, C., Webb-Peploe, M., Van Belle, E., & McFadden, E. P.
- Venue
- Circulation
- Published
- 1998-10-20
- Volume
- 98
- Issue
- 16
- Pages
- 1597-1603
- ISSN
- 0009-7322 (ISSN-L)
- 1524-4539
- OpenAlex
- W2121047179
- Cited by
- 583
- References
- 8
- FWCI
- 25.23
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.