Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 393

The DOI matches its Crossref record; 4 of the 4 references it cites were found in a registry or an index.

Vasoactive Drugs Influence Aortic Augmentation Index Independently of Pulse-Wave Velocity in Healthy Men

Open access
Kelly, R. P., Millasseau, S. C., Ritter, J. M., Chowienczyk, P. J.·2001·Hypertension

Abstract

Abstract —Aortic augmentation index, a measure of central systolic blood pressure augmentation arising mainly from pressure-wave reflection, increases with vascular aging. The augmentation index is influenced by aortic pulse-wave velocity (related to aortic stiffness) and by the site and extent of wave reflection. To clarify the relative influence of pulse-wave velocity and wave reflection on the augmentation index, we studied the association between augmentation index, pulse-wave velocity, and age and examined the effects of vasoactive drugs to determine whether altering vascular tone has differential effects on pulse-wave velocity and the augmentation index. We made simultaneous measurements of the augmentation index and carotid-to-femoral pulse-wave velocity in 50 asymptomatic men aged 19 to 74 years at baseline and, in a subset, during the administration of nitroglycerin, angiotensin II, and saline vehicle. The aortic augmentation index was obtained by radial tonometry (Sphygmocor device, PWV Medical) with the use of an inbuilt radial to aortic transfer function. In multiple regression analysis, the aortic augmentation index was independently correlated only with age ( R =0.58, P <0.0001). Nitroglycerin (3 to 300 μg/min IV) reduced the aortic augmentation index from 4.8±2.3% to −11.9±5.3% (n=10, P <0.002). Angiotensin II (75 to 300 ng/min IV) increased the aortic augmentation index from 9.3±2.4% to 18.3±2.9% (n=12, P <0.001). These drugs had small effects on aortic pulse-wave velocity, producing mean changes from baseline of <1 m/s (each P <0.05). In healthy men, vasoactive drugs may change aortic augmentation index independently from aortic pulse-wave velocity.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1161/01.hyp.37.6.1429

Cites

4 of 4 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 4 references

Cited by

See all 393

Metadata

Authors
Kelly, R. P., Millasseau, S. C., Ritter, J. M., & Chowienczyk, P. J.
Venue
Hypertension
Published
2001-06
Volume
37
Issue
6
Pages
1429-1433
ISSN
  • 0194-911X (ISSN-L)
  • 1524-4563
OpenAlex
W2120171412
Cited by
393
References
4
FWCI
10.88
Type
journal article
Language
en
Open access
bronze

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Vasoactive Drugs Influence Aortic Augmentation Index Independently of Pulse-Wave Velocity in Healthy Men. https://app.cochat.ai/papers/10.1161/01.hyp.37.6.1429
The paper
Kelly, R. P., Millasseau, S. C., Ritter, J. M., & Chowienczyk, P. J. (2001). Vasoactive Drugs Influence Aortic Augmentation Index Independently of Pulse-Wave Velocity in Healthy Men. Hypertension. https://doi.org/10.1161/01.hyp.37.6.1429

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.