Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 323

The DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.

Mitochondrial Sources of H 2 O 2 Generation Play a Key Role in Flow-Mediated Dilation in Human Coronary Resistance Arteries

Liu, Yanping, Zhao, Hongtao, Li, Hongwei, Kalyanaraman, B., Nicolosi, Alfred C., Gutterman, David D.·2003·Circulation Research

Abstract

We previously showed that hydrogen peroxide (H 2 O 2 ) contributes to flow-induced dilation in human coronary resistance arteries (HCRAs); however, the source of this H 2 O 2 is not known. We hypothesized that the H 2 O 2 is derived from superoxide (O 2 ·− ) generated by mitochondrial respiration. HCRAs were dissected from right atrial appendages obtained from patients during cardiac surgery and cannulated with micropipettes. H 2 O 2 -derived radicals and O 2 ·− were detected by electron spin resonance (ESR) using BMPO as the spin trap and by histofluorescence using hydroethidine (HE, 5 μmol/L) and dichlorodihydrofluorescein (DCFH, 5 μmol/L). Diameter changes to increases in pressure gradients (20 and 100 cm H 2 O) were examined in the absence and the presence of rotenone (1 μmol/L), myxothiazol (100 nmol/L), cyanide (1 μmol/L), mitochondrial complex I, III, and IV inhibitors, respectively, and apocynin (3 mmol/L), a NADPH oxidase inhibitor. At a pressure gradient of 100 cm H 2 O, ubisemiquinone and hydroxyl radicals were detected from effluents of vessels. Including superoxide dismutase and catalase in the perfusate reduced the ESR signals. Relative ethidium and DCFH fluorescence intensities in HCRAs exposed to flow were enhanced (1.45±0.15 and 1.57±0.12, respectively compared with no-flow) and were inhibited by rotenone (0.87±0.17 and 0.95±0.07). Videomicroscopic studies showed that rotenone and myxothiazol blocked flow-induced dilation (% max. dilation at 100 cm H 2 O: rotenone, 74±3% versus 3±13%; myxothiazol, 67±3% versus 28±4%; P <0.05). Neither cyanide nor apocynin altered flow-induced dilation. These results suggest that shear stress induced H 2 O 2 formation, and flow-induced dilation is derived from O 2 ·− originating from mitochondrial respiration.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1161/01.res.0000091261.19387.ae

Cites

3 of 3 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 3 references

Cited by

Metadata

Authors
Liu, Y., Zhao, H., Li, H., Kalyanaraman, B., Nicolosi, A. C., & Gutterman, D. D.
Venue
Circulation Research
Published
2003-09-19
Volume
93
Issue
6
Pages
573-580
ISSN
  • 0009-7330 (ISSN-L)
  • 1524-4571
OpenAlex
W2166150279
Cited by
323
References
3
FWCI
8.32
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.