Coronary diastolic pressure-flow relation and zero flow pressure explained on the basis of intramyocardial compliance.
Open accessThe DOI matches its Crossref record; 24 of the 24 references it cites were found in a registry or an index.
Abstract
In the controversy about the mechanisms determining the high zero flow pressures and the further interpretation of coronary diastolic pressure flow relations, this paper takes a stand in favor of intramyocardial compliance as the primary cause of the high zero flow pressures. An attempt has been made to estimate the compliance distribution within the coronary circulation and to show the specific effect of intramyocardial compliance on arterial and venous pressure-flow relations. Since no data are available on the distensibility of coronary arterioles and capillaries, these data were taken from studies on mesenteric vessels. Based on these data, it is shown that, depending on the transmural pressure, smooth muscle tone may either increase or decrease arteriolar compliance. A compliance distribution has been proposed based on assumed pressure, volume, and distensibility distributions. For all but the venous division of the circulation, experimental data on volume could be found in the literature. Based on this compartmental analysis, it is predicted that overall intramyocardial compliance may exceed epicardial arterial compliance by a factor 45. The literature presenting functional evidence for intramyocardial compliance effects has been reviewed. Experimental results on venous outflow during long diastoles have been analyzed. Pf = 0 coronary pressure at zero flow, is higher when measured later in diastole. It is shown that this may be explained by charging of intramyocardial compliance in the period before flow ceases. The discrepancy between results on pressure-flow relations in the fully dilated bed and autoregulated bed are related to the differences in pressure, resistance, and compliance distributions.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Mulvany, M. J., & Halpern, W. (1977) · Circulation Research · doi:10.1161/01.res.41.1.19 · Cited by 2,140
Relation of Structure to Function of the Tissues of the Wall of Blood Vessels
Burton, A. C. (1954) · Physiological Reviews · doi:10.1152/physrev.1954.34.4.619 · Cited by 798 · cited 1×
“From earlier studies on the distensibility of capillaries, it was concluded that capillaries behave as rigid tunnels (Burton, 1954; Baez et al., 1960; Fung et al., 1966).”
Hemodynamics of collapsible vessels with tone: the vascular waterfall
Permutt, S., & Riley, R. L. (1963) · Journal of Applied Physiology · doi:10.1152/jappl.1963.18.5.924 · Cited by 545
Inhibition of coronary blood flow by a vascular waterfall mechanism.
Downey, J. M., & Kirk, E. S. (1975) · Circulation Research · doi:10.1161/01.res.36.6.753 · Cited by 345
Spaan, J. A., Breuls, N. P., & Laird, J. D. (1981) · Circulation Research · doi:10.1161/01.res.49.3.584 · Cited by 322
Self-citationDiastolic coronary artery pressure-flow relations in the dog.
Bellamy, R. F. (1978) · Circulation Research · doi:10.1161/01.res.43.1.92 · Cited by 300 · cited 2×
“The two hypotheses which represent the two extremes in thought as to the cause of the high intercept pressure are: (1) Coronary flow stops at high pressures because of a Starling resistor effect in the resistance vessels (Permutt and Riley, 1963; Bellamy, 1978; Riley, 1982).”
Roberts, J. T., & Wearn, J. T. (1941) · American Heart Journal · doi:10.1016/s0002-8703(41)90726-3 · Cited by 229
The collagen matrix of the heart.
Borg, T. K., & Caulfield, J. (1981) · PubMed · Cited by 226
Coronary blood flow in experimental canine left ventricular hypertrophy.
O'Keefe, D. D., Hoffman, J. I., Cheitlin, R., O'Neill, M. J., Allard, J. R., & Shapkin, E. (1978) · Circulation Research · doi:10.1161/01.res.43.1.43 · Cited by 188 · cited 1×
“However, capillary volume in the postmortem dog heart has been determined by O'Keefe et al. (1978). They reported a capillary volume fraction in the heart of 27%.”
Capillary diameter and geometry in cardiac and skeletal muscle studied by means of corrosion casts
Potter, R. F., & Groom, A. C. (1983) · Microvascular Research · doi:10.1016/0026-2862(83)90044-4 · Cited by 180
Cited by
Regulation of coronary blood flow during exercise
Duncker, D. J., & Bache, R. J. (2008) · Physiological Reviews · doi:10.1152/physrev.00045.2006 · Cited by 936
“Second, the increased contractility increases systolic compression of the intramural coronary vessels (325, 385, 533, 563).”
BackgroundCross-Talk Between Cardiac Muscle and Coronary Vasculature
Westerhof, N., Boer, C., Lamberts, R. R., & Sipkema, P. (2006) · Physiological Reviews · doi:10.1152/physrev.00029.2005 · Cited by 270
Laughlin, M. H., Davis, M. J., Secher, N. H., van Lieshout, J. J., Arce‐Esquivel, A. A., Simmons, G. H., Bender, S. B., Padilla, J., Bache, R. J., Merkus, D., et al. (2012) · Comprehensive Physiology · doi:10.1002/cphy.c100048 · Cited by 241
Transmural myocardial perfusion
Hoffman, J. I. E. (1987) · Progress in Cardiovascular Diseases · doi:10.1016/0033-0620(87)90016-8 · Cited by 214
Control of Blood Flow to Cardiac and Skeletal Muscle During Exercise
Laughlin, M. H., Korthuis, R. J., Duncker, D. J., & Bache, R. J. (1996) · Comprehensive Physiology · doi:10.1002/cphy.cp120116 · Cited by 188
Metadata
- Authors
- Spaan, J. A.
- Venue
- Circulation Research
- Published
- 1985-03
- Volume
- 56
- Issue
- 3
- Pages
- 293-309
- ISSN
- 0009-7330 (ISSN-L)
- 1524-4571
- OpenAlex
- W2165479769
- Cited by
- 195
- References
- 24
- FWCI
- 11.79
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.