Coronary diastolic pressure-flow relation and zero flow pressure explained on the basis of intramyocardial compliance.
Open accessThe DOI matches its Crossref record; 24 of the 24 references it cites were found in a registry or an index.
Abstract
In the controversy about the mechanisms determining the high zero flow pressures and the further interpretation of coronary diastolic pressure flow relations, this paper takes a stand in favor of intramyocardial compliance as the primary cause of the high zero flow pressures. An attempt has been made to estimate the compliance distribution within the coronary circulation and to show the specific effect of intramyocardial compliance on arterial and venous pressure-flow relations. Since no data are available on the distensibility of coronary arterioles and capillaries, these data were taken from studies on mesenteric vessels. Based on these data, it is shown that, depending on the transmural pressure, smooth muscle tone may either increase or decrease arteriolar compliance. A compliance distribution has been proposed based on assumed pressure, volume, and distensibility distributions. For all but the venous division of the circulation, experimental data on volume could be found in the literature. Based on this compartmental analysis, it is predicted that overall intramyocardial compliance may exceed epicardial arterial compliance by a factor 45. The literature presenting functional evidence for intramyocardial compliance effects has been reviewed. Experimental results on venous outflow during long diastoles have been analyzed. Pf = 0 coronary pressure at zero flow, is higher when measured later in diastole. It is shown that this may be explained by charging of intramyocardial compliance in the period before flow ceases. The discrepancy between results on pressure-flow relations in the fully dilated bed and autoregulated bed are related to the differences in pressure, resistance, and compliance distributions.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Mulvany, M. J., & Halpern, W. (1977) · Circulation Research · doi:10.1161/01.res.41.1.19 · Cited by 2,140
Relation of Structure to Function of the Tissues of the Wall of Blood Vessels
Burton, A. C. (1954) · Physiological Reviews · doi:10.1152/physrev.1954.34.4.619 · Cited by 798 · cited 1×
“From earlier studies on the distensibility of capillaries, it was concluded that capillaries behave as rigid tunnels (Burton, 1954; Baez et al., 1960; Fung et al., 1966).”
Hemodynamics of collapsible vessels with tone: the vascular waterfall
Permutt, S., & Riley, R. L. (1963) · Journal of Applied Physiology · doi:10.1152/jappl.1963.18.5.924 · Cited by 545
Inhibition of coronary blood flow by a vascular waterfall mechanism.
Downey, J. M., & Kirk, E. S. (1975) · Circulation Research · doi:10.1161/01.res.36.6.753 · Cited by 345
Spaan, J. A., Breuls, N. P., & Laird, J. D. (1981) · Circulation Research · doi:10.1161/01.res.49.3.584 · Cited by 322
Self-citationDiastolic coronary artery pressure-flow relations in the dog.
Bellamy, R. F. (1978) · Circulation Research · doi:10.1161/01.res.43.1.92 · Cited by 300 · cited 2×
“The two hypotheses which represent the two extremes in thought as to the cause of the high intercept pressure are: (1) Coronary flow stops at high pressures because of a Starling resistor effect in the resistance vessels (Permutt and Riley, 1963; Bellamy, 1978; Riley, 1982).”
Roberts, J. T., & Wearn, J. T. (1941) · American Heart Journal · doi:10.1016/s0002-8703(41)90726-3 · Cited by 229
The collagen matrix of the heart.
Borg, T. K., & Caulfield, J. (1981) · PubMed · Cited by 226
Coronary blood flow in experimental canine left ventricular hypertrophy.
O'Keefe, D. D., Hoffman, J. I., Cheitlin, R., O'Neill, M. J., Allard, J. R., & Shapkin, E. (1978) · Circulation Research · doi:10.1161/01.res.43.1.43 · Cited by 188 · cited 1×
“However, capillary volume in the postmortem dog heart has been determined by O'Keefe et al. (1978). They reported a capillary volume fraction in the heart of 27%.”
Capillary diameter and geometry in cardiac and skeletal muscle studied by means of corrosion casts
Potter, R. F., & Groom, A. C. (1983) · Microvascular Research · doi:10.1016/0026-2862(83)90044-4 · Cited by 180
Elastic Environment of the Capillary Bed
Fung, Y. C., Zweifach, B. W., & Intaglietta, M. (1966) · Circulation Research · doi:10.1161/01.res.19.2.441 · Cited by 156 · cited 1×
“From earlier studies on the distensibility of capillaries, it was concluded that capillaries behave as rigid tunnels (Burton, 1954; Baez et al., 1960; Fung et al., 1966).”
Tomanek, R. J., Searls, J. C., & Lachenbruch, P. A. (1982) · Circulation Research · doi:10.1161/01.res.51.3.295 · Cited by 144
Diastolic coronary artery pressure-flow relations in the dog.
FBellamy, R. (1978) · Circulation Research · Cited by 143
Mechanics of Vascular Smooth Muscle
Murphy, R. A. (1980) · Comprehensive physiology · doi:10.1002/cphy.cp020213 · Cited by 110
Epicardial Coronary Artery Compliance in the Dog
DOUGLAS, J. E., & Greenfield, J. C. (1970) · Circulation Research · doi:10.1161/01.res.27.6.921 · Cited by 91 · cited 1×
“Douglas and Greenfield (1970) injected silicone into the left main coronary artery of a dog, after having first 297”
Propagation velocity and reflection of pressure waves in the canine coronary artery
Arts, T. G. J., Kruger, R. T., Gerven, W. V., Lambregts, J., & Reneman, R. S. (1979) · American Journal of Physiology-Heart and Circulatory Physiology · doi:10.1152/ajpheart.1979.237.4.h469 · Cited by 80
The distensibility of single capillaries and venules in the cat mesentery
Smaje, L. H., Fraser, P. A., & Clough, G. F. (1980) · Microvascular Research · doi:10.1016/0026-2862(80)90064-3 · Cited by 74
Control of Coronary Blood Flow
Klocke, F. J., & Ellis, A. K. (1980) · Annual Review of Medicine · doi:10.1146/annurev.me.31.020180.002421 · Cited by 73 · cited 1×
“Obviously, the interpretation of the overall coronary resistance, defined in Figure 1, depends also on the mechanism responsible for the diastolic pressureflow relation and, in particular, for the high zero flow pressure (Bellamy, 1980; Klocke and Ellis, 1980).”
Dole, W. P., & BISHOP, V. S. (1982) · Circulation Research · doi:10.1161/01.res.51.3.261 · Cited by 69 · cited 7×
“(1981) with the decaying pressure technique are lower than those obtained by Dole and Bishop (1982a) obtained with a similar technique.”
InfluentialDamon, D. H., & Duling, B. R. (1984) · Microvascular Research · doi:10.1016/0026-2862(84)90043-8 · Cited by 68
Uhlig, P. N., Baer, R. W., Vlahakes, G. J., Hanley, F. L., Messina, L. M., & Hoffman, J. I. E. (1984) · Circulation Research · doi:10.1161/01.res.55.2.238 · Cited by 63
The dynamic elastic properties of the canine left circumflex coronary artery
Gow, B. S., Schonfeld, D., & Patel, D. J. (1974) · Journal of Biomechanics · doi:10.1016/0021-9290(74)90001-3 · Cited by 61
Diameter, wall tension, and flow in mesenteric arterioles during autoregulation
Burrows, M. E., & Johnson, P. C. (1981) · American Journal of Physiology-Heart and Circulatory Physiology · doi:10.1152/ajpheart.1981.241.6.h829 · Cited by 57 · cited 1×
“, Burrows and Johnson, 1981). This effect is illustrated in Figure 2a by curve 1. Cross-sectional area and arteriolar volume will decrease until maximal smooth muscle tone is achieved. Thereafter, volume will increase with pressure. Variation of smooth muscle tone must also be taken into account when interpreting the…”
Regional blood flow, microvascular blood content and tissue haematocrit in canine myocardium
Eliasen, P., Amtorp, O., Tøndevold, E., & Haunsø, S. (1982) · Cardiovascular Research · doi:10.1093/cvr/16.10.593 · Cited by 33
Cited by
Regulation of coronary blood flow during exercise
Duncker, D. J., & Bache, R. J. (2008) · Physiological Reviews · doi:10.1152/physrev.00045.2006 · Cited by 936
“Second, the increased contractility increases systolic compression of the intramural coronary vessels (325, 385, 533, 563).”
BackgroundCross-Talk Between Cardiac Muscle and Coronary Vasculature
Westerhof, N., Boer, C., Lamberts, R. R., & Sipkema, P. (2006) · Physiological Reviews · doi:10.1152/physrev.00029.2005 · Cited by 270
Laughlin, M. H., Davis, M. J., Secher, N. H., van Lieshout, J. J., Arce‐Esquivel, A. A., Simmons, G. H., Bender, S. B., Padilla, J., Bache, R. J., Merkus, D., et al. (2012) · Comprehensive Physiology · doi:10.1002/cphy.c100048 · Cited by 241
Transmural myocardial perfusion
Hoffman, J. I. E. (1987) · Progress in Cardiovascular Diseases · doi:10.1016/0033-0620(87)90016-8 · Cited by 214
Control of Blood Flow to Cardiac and Skeletal Muscle During Exercise
Laughlin, M. H., Korthuis, R. J., Duncker, D. J., & Bache, R. J. (1996) · Comprehensive Physiology · doi:10.1002/cphy.cp120116 · Cited by 188
Metadata
- Authors
- Spaan, J. A.
- Venue
- Circulation Research
- Published
- 1985-03
- Volume
- 56
- Issue
- 3
- Pages
- 293-309
- ISSN
- 0009-7330 (ISSN-L)
- 1524-4571
- OpenAlex
- W2165479769
- Cited by
- 195
- References
- 24
- FWCI
- 11.79
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.