CoChat

Carotid Artery Stenting Protected With an Emboli Containment System

Open access
Whitlow, Patrick L., Lylyk, Pedro, Londero, Hugo, Mendiz, Oscar A., Mathias, Klaus, Jaeger, Horst, Parodi, Juan, Schönholz, Claudio, Milei, Jose · 2002 · Stroke
Cited by 176

The DOI matches its Crossref record; 15 of the 15 references it cites were found in a registry or an index.

Abstract

Background and Purpose — Fear of distal embolization and stroke has aroused concern regarding carotid stenting. Devices to protect the cerebral circulation may make carotid stenting safer. Methods — A multidisciplinary study group tested a balloon occlusion-aspiration emboli entrapment device in conjunction with carotid stenting. The device consists of an elastomeric balloon on a steerable wire with a detachable adapter that inflates and deflates the distal temporary occlusion balloon. An aspiration catheter is used to remove trapped emboli after stenting and before occlusion balloon deflation. Results — Seventy-five patients with severe internal carotid artery stenosis were treated with stents deployed with this cerebrovasculature protection system. All 75 patients (100%) had grossly visible particulate material aspirated, and all were treated successfully without major or minor stroke or death at 30 days. Preintervention stenosis was 81±10%, and residual stenosis was 5±7%. Nine patients (12%) had angiographic evidence of thrombus before intervention, but no patient had thrombus or vessel cutoff after the procedure. Four patients (5%) developed transient neurological symptoms during protection balloon occlusion, but symptoms resolved with balloon deflation. The 22 to 667 particles aspirated per patient ranged from 3.6 to 5262 μm in maximum diameter (mean, 203±256 μm). These particles included fibrous plaque debris, lipid or cholesterol vacuoles, and calcific plaque fragments. Conclusions — Protected carotid stenting was performed successfully and safely in this study early in the experience with cerebrovascular protection devices. Particulate emboli are frequent with stenting, and cerebral protection will likely be necessary to minimize stroke. Randomized trials comparing protected carotid stenting with endarterectomy are warranted.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1161/01.str.0000013947.17575.b3

Cites

15 of 15 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Cited by

See all 176

Metadata

Authors
Whitlow, P. L., Lylyk, P., Londero, H., Mendiz, O. A., Mathias, K., Jaeger, H., Parodi, J., Schönholz, C., & Milei, J.
Venue
Stroke
Published
2002-05
Volume
33
Issue
5
Pages
1308-1314
ISSN
  • 0039-2499 (ISSN-L)
  • 1524-4628
OpenAlex
W2151347844
Cited by
176
References
15
FWCI
21.12
Type
journal article
Language
en
Open access
bronze

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.