The Stroke Patient Who Woke Up: Clinical and Radiological Features, Including Diffusion and Perfusion MRI
The DOI matches its Crossref record; 33 of the 33 references it cites were found in a registry or an index.
Abstract
Background and Purpose — Time of stroke onset is uncertain for patients who wake from sleep with stroke. Functional imaging techniques may allow estimation of benefit and risk of acute stroke therapy. We compared the clinical and multimodal MRI findings of patients with uncertain stroke onset with those with known onset time. Methods — Patients imaged within 24 hours of ischemic stroke onset between January 1997 and June 2000 were identified from a prospective stroke registry. Clinical and imaging data from patients with known stroke onset (group I) were compared with those who woke with stroke (group II). Results — A total of 364 patients were identified, of whom 100 (27%) woke from sleep with stroke. Group I and group II did not differ in age, gender, National Institutes of Health Stroke Scale, or TOAST (Trial of Org 10172 in Acute Stroke Treatment) diagnoses. Time from stroke onset was shorter in group I (mean 6.0 versus 13.3 hours, P <0.001); time from detection did not differ between groups (6.0 versus 5.9 hours). Within 3 hours, diffusion-weighted imaging (DWI) and perfusion-weighted imaging (PWI) lesion volumes were similar in both groups; DWI-PWI mismatch was present in 82% of group I and 73% of group II patients. Mean apparent diffusion coefficient of water (ADC) of group I patients was negatively associated with DWI volume (β=−0.324, P =0.004) and time from stroke onset (β=−0.238, P =0.031) in multivariate analysis. The mean ADC of group II patients was lower than that of group I patients within 3 hours of stroke detection (mean 556 versus 665 μm 2 /s, P <0.01), but individual group II patients had ADC values as high as 742 μm 2 /s, in addition to a DWI-PWI mismatch pattern. Conclusions — Onset time is uncertain in over one quarter of acute ischemic stroke patients. Clinical features of these patients do not differ significantly from those with known onset time. Some patients who wake with stroke seem to have favorable imaging characteristics for acute stroke therapy. Further study is needed to determine whether criteria for therapy based on imaging parameters can safely be applied to these patients.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Adams, H. P., Bendixen, B. H., Kappelle, L. J., Biller, J., Love, B. B., Gordon, D. L., & Marsh, E. E. (1993) · Stroke · doi:10.1161/01.str.24.1.35 · Cited by 12,335
Tissue Plasminogen Activator for Acute Ischemic Stroke
(1995) · New England Journal of Medicine · doi:10.1056/nejm199512143332401 · Cited by 11,654
Moseley, M. E., Cohen, Y., Mintorovitch, J., Chileuitt, L., Shimizu, H., Kucharczyk, J., Wendland, M. F., & Weinstein, P. R. (1990) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910140218 · Cited by 1,644
Why are stroke patients excluded from TPA therapy?: An analysis of patient eligibility
Barber, P. A., Zhang, J., Demchuk, A. M., Hill, M. D., & Buchan, A. M. (2001) · Neurology · doi:10.1212/wnl.56.8.1015 · Cited by 704
Kidwell, C. S., Saver, J. L., Mattiello, J., Starkman, S., Vinuela, F., Duckwiler, G., Gobin, Y. P., Jahan, R., Vespa, P., Kalafut, M., et al. (2000) · Annals of Neurology · doi:10.1002/1531-8249(200004)47:4<462::aid-ana9>3.0.co;2-y · Cited by 692
The ischemic penumbra: Operationally defined by diffusion and perfusion MRI
Schlaug, G., Benfield, A., Baird, A. E., Siewert, B., Lövblad, K. O., Parker, R. A., Edelman, R. R., & Warach, S. (1999) · Neurology · doi:10.1212/wnl.53.7.1528 · Cited by 663
Self-citationCircadian Variation in the Timing of Stroke Onset: A Meta-analysis
Elliott, W. J. (1998) · Stroke · doi:10.1161/01.str.29.5.992 · Cited by 638
Baird, A. E., Benfield, A., Schlaug, G., Siewert, B., Lövblad, K., Edelman, R. R., & Warach, S. (1997) · Annals of Neurology · doi:10.1002/ana.410410506 · Cited by 581
Self-citationPrediction of stroke outcome with echoplanar perfusion- and diffusion-weighted MRI
Barber, P. A., Darby, D. G., Desmond, P. M., Yang, Q., Gerraty, R. P., Jolley, D., Donnan, G. A., Tress, B. M., & Davis, S. M. (1998) · Neurology · doi:10.1212/wnl.51.2.418 · Cited by 559
Time course of the apparent diffusion coefficient (ADC) abnormality in human stroke
Schlaug, G., Siewert, B., Benfield, A., Edelman, R. R., & Warach, S. (1997) · Neurology · doi:10.1212/wnl.49.1.113 · Cited by 550
Self-citation
Cited by
Aoki, J., Kimura, K., Shibazaki, K., & Sakamoto, Y. (2013) · Cerebrovascular Diseases Extra · doi:10.1159/000348552 · Cited by 1,929
European Stroke Organisation (ESO) guidelines on intravenous thrombolysis for acute ischaemic stroke
Berge, E., Whiteley, W., Audebert, H., De Marchis, G., Fonseca, A. C., Padiglioni, C., Pérez de la Ossa, N., Strbian, D., Tsivgoulis, G., & Turc, G. (2021) · European Stroke Journal · doi:10.1177/2396987321989865 · Cited by 1,355
MRI-Guided Thrombolysis for Stroke with Unknown Time of Onset
Thomalla, G., Simonsen, C. Z., Boutitie, F., Andersen, G., Berthezene, Y., Cheng, B., Cheripelli, B., Cho, T.-H., Fazekas, F., Fiehler, J., et al. (2018) · New England Journal of Medicine · doi:10.1056/nejmoa1804355 · Cited by 1,327
Thomalla, G., Cheng, B., Ebinger, M., Hao, Q., Tourdias, T., Wu, O., Kim, J. S., Breuer, L., Singer, O. C., Warach, S., et al. (2011) · The Lancet Neurology · doi:10.1016/s1474-4422(11)70192-2 · Cited by 602
Adams, H. P., Effron, M. B., Torner, J., Dávalos, A., Frayne, J., Teal, P., Leclerc, J., Oemar, B., Padgett, L., Barnathan, E. S., et al. (2008) · Stroke · doi:10.1161/strokeaha.106.476648 · Cited by 375
Thomalla, G., Rossbach, P., Rosenkranz, M., Siemonsen, S., Krützelmann, A., Fiehler, J., & Gerloff, C. (2009) · Annals of Neurology · doi:10.1002/ana.21651 · Cited by 248
Population-based study of wake-up strokes
Mackey, J., Kleindorfer, D., Sucharew, H., Moomaw, C. J., Kissela, B. M., Alwell, K., Flaherty, M. L., Woo, D., Khatri, P., Adeoye, O., et al. (2011) · Neurology · doi:10.1212/wnl.0b013e318219fb30 · Cited by 242
Imaging-Based Decision Making in Thrombolytic Therapy for Ischemic Stroke: Present Status
Schellinger, P. D., Fiebach, J. B., & Hacke, W. (2003) · Stroke · doi:10.1161/01.str.0000051504.10095.9c · Cited by 241
Tietze, A., Blicher, J., Mikkelsen, I. K., Østergaard, L., Strother, M. K., Smith, S. A., & Donahue, M. J. (2014) · NMR in Biomedicine · doi:10.1002/nbm.3048 · Cited by 171
“Moreover, about one-quarter of patients wake up with stroke symptoms and are currently not eligible for tPA treatment or mechanical thrombectomy (43).”
Abciximab Emergent Stroke Treatment Trial (AbESTT) Investigators (2005) · Stroke · doi:10.1161/01.str.0000157668.39374.56 · Cited by 160
Stroke during sleep and obstructive sleep apnea: there is a link
Mohammad, Y., Almutlaq, A., Al-Ruwaita, A., Aldrees, A., Alsubaie, A., & Al-Hussain, F. (2019) · Neurological Sciences · doi:10.1007/s10072-019-03753-2 · Cited by 32
Metadata
- Authors
- Fink, J. N., Kumar, S., Horkan, C., Linfante, I., Selim, M. H., Caplan, L. R., & Schlaug, G.
- Venue
- Stroke
- Published
- 2002-04
- Volume
- 33
- Issue
- 4
- Pages
- 988-993
- ISSN
- 0039-2499 (ISSN-L)
- 1524-4628
- OpenAlex
- W2062047217
- Cited by
- 233
- References
- 33
- FWCI
- 4.04
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.