CoChat

Atherosclerotic Changes in the Carotid Artery Bulb as Measured by B-Mode Ultrasound Are Associated With the Extent of Coronary Atherosclerosis

Hulthe, Johannes, Wikstrand, John, Emanuelsson, Håkan, Wiklund, Olov, de Feyter, Pim J., Wendelhag, Inger · 1997 · Stroke
Cited by 197

The DOI matches its Crossref record.

Abstract

Background and Purpose Ultrasound is increasingly used to measure atherosclerotic development in carotid and femoral arteries. The aim of this study was to investigate the relationship between coronary atherosclerosis as measured by quantitative angiography and peripheral atherosclerosis as measured by ultrasound in three different arterial regions. Methods Patients (n=32) with at least two coronary segments with visible signs of atherosclerosis as defined in a computer-assisted analysis of coronary angiograms were also examined with B-mode ultrasound. The extent of coronary atherosclerosis was expressed as the average diameter stenosis of coronary segments, and peripheral atherosclerosis was defined as intima-media thickness (IMT) and plaque occurrence in the common carotid artery, the carotid bulb, and the common femoral artery. Results The results showed a significant correlation between the ultrasound measurement of IMT of the carotid bulb and diameter stenosis of the included coronary segments ( r =.68, P =.01) and of carotid plaques and diameter stenosis ( P <.001). The correlation between common carotid IMT and diameter stenosis of included coronary segments was not statistically significant ( r =.31, NS). There were no significant relationships between common femoral IMT or femoral plaques and diameter stenosis of included coronary segments. Conclusions Although this study is small, it points to a very important aspect of ultrasound measurements of atherosclerosis: measurements performed in the common carotid artery or the femoral artery may not relate to coronary atherosclerosis in the same way as measurements performed in the carotid bulb. The findings underline the importance of measuring IMT not only in the common carotid artery but also in the carotid bulb and present data separately. These results have to be confirmed in a larger-scale study.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1161/01.str.28.6.1189

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

Metadata

Authors
Hulthe, J., Wikstrand, J., Emanuelsson, H., Wiklund, O., de Feyter, P. J., & Wendelhag, I.
Venue
Stroke
Published
1997-06
Volume
28
Issue
6
Pages
1189-1194
ISSN
  • 0039-2499 (ISSN-L)
  • 1524-4628
OpenAlex
W2004072822
Cited by
197
References
0
FWCI
3.49
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.