Atrial Fibrillation Ablation Strategies for Paroxysmal Patients: Randomized Comparison Between Different Techniques
The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.
Abstract
Background— Whether different ablation strategies affect paroxysmal atrial fibrillation (AF) long-term freedom from AF/atrial tachyarrhythmia is unclear. We sought to compare the effect of 3 different ablation approaches on the long-term success in patients with paroxysmal AF. Methods and Results— One hundred three consecutive patients with paroxysmal AF scheduled for ablation and presenting in the electrophysiology laboratory in AF were selected for this study. Patients were randomized to pulmonary vein antrum isolation (PVAI; n=35) versus biatrial ablation of the complex fractionated atrial electrograms (CFAEs; n=34) versus PVAI followed by CFAEs (n=34). Patients were given event recorders and followed up at 3, 6, 9, 12, and 15 months postablation. There was no statistical significant difference between the groups in term of sex, age, AF duration, left atrial size, and ejection fraction. At 1 year follow-up, freedom from AF/atrial tachyarrhythmia was documented in 89% of patients in the PVAI group, 91% in the PVAI plus CFAEs group, and 23% in the CFAEs group ( P <0.001) after a single procedure and with antiarrhythmic drugs. Conclusion— No difference in terms of success rate was seen between PVAI alone and PVAI associated with defragmentation. CFAEs ablation alone had the smallest impact on AF recurrences at 1-year follow-up. These results suggest that antral isolation is sufficient to treat most patients with paroxysmal AF.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Fuster, V., Rydén, L. E., Cannom, D. S., Crijns, H. J., Curtis, A. B., Ellenbogen, K. A., Halperin, J. L., Le Heuzey, J.-Y., Kay, G. N., Lowe, J. E., et al. (2006) · Circulation · doi:10.1161/circulationaha.106.177292 · Cited by 2,805 · cited 2×
“CFAEs only Group (Group II) CFAEs were defined as: (1) atrial electrograms with two deflections or more”
BackgroundMethodWazni, O. M., Marrouche, N. F., Martin, D. O., Verma, A., Bhargava, M., Saliba, W., Bash, D., Schweikert, R., Brachmann, J., Gunther, J., et al. (2005) · JAMA · doi:10.1001/jama.293.21.2634 · Cited by 1,121 · cited 2×
“Additional lesions such as mitral isthmus ablation (5) or antrum isolation (14) have been reported to increase this success to approximately”
Background
Cited by
Joglar, J. A., Chung, M. K., Armbruster, A. L., Benjamin, E. J., Chyou, J. Y., Cronin, E. M., Deswal, A., Eckhardt, L. L., Goldberger, Z. D., Gopinathannair, R., et al. (2024) · Circulation · doi:10.1161/cir.0000000000001193 · Cited by 2,765
Self-citation2023 ACC/AHA/ACCP/HRS Guideline for the Diagnosis and Management of Atrial Fibrillation
Joglar, J. A., Chung, M. K., Armbruster, A. L., Benjamin, E. J., Chyou, J. Y., Cronin, E. M., Deswal, A., Eckhardt, L. L., Goldberger, Z. D., Gopinathannair, R., et al. (2024) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2023.08.017 · Cited by 933
Self-citationCalkins, H., Reynolds, M. R., Spector, P., Sondhi, M., Xu, Y., Martin, A., Williams, C. J., & Sledge, I. (2009) · Circulation Arrhythmia and Electrophysiology · doi:10.1161/circep.108.824789 · Cited by 847
Left Atrial Appendage: An Underrecognized Trigger Site of Atrial Fibrillation
Di Biase, L., Burkhardt, J. D., Mohanty, P., Sanchez, J., Mohanty, S., Horton, R., Gallinghouse, G. J., Bailey, S. M., Zagrodzky, J. D., Santangeli, P., et al. (2010) · Circulation · doi:10.1161/circulationaha.109.928903 · Cited by 644
Self-citationDi Biase, L., Burkhardt, J. D., Santangeli, P., Mohanty, P., Sanchez, J. E., Horton, R., Gallinghouse, G. J., Themistoclakis, S., Rossillo, A., Lakkireddy, D., et al. (2014) · Circulation · doi:10.1161/circulationaha.113.006426 · Cited by 485
Self-citationDi Biase, L., Burkhardt, J. D., Mohanty, P., Mohanty, S., Sanchez, J. E., Trivedi, C., Güneş, M., Gökoğlan, Y., Gianni, C., Horton, R. P., et al. (2016) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2016.07.770 · Cited by 445
Self-citationComplications of Catheter Ablation of Atrial Fibrillation: A Systematic Review
Gupta, A., Perera, T., Ganesan, A., Sullivan, T., Lau, D. H., Roberts-Thomson, K. C., Brooks, A. G., & Sanders, P. (2013) · Circulation: Arrhythmia and Electrophysiology · doi:10.1161/circep.113.000768 · Cited by 317
Di Biase, L., Burkhardt, J. D., Mohanty, P., Sanchez, J., Horton, R., Gallinghouse, G. J., Lakkireddy, D., Verma, A., Khaykin, Y., Hongo, R., et al. (2010) · Circulation · doi:10.1161/circulationaha.109.921320 · Cited by 294
Self-citationRate- and Rhythm-Control Therapies in Patients With Atrial Fibrillation: A Systematic Review
Al-Khatib, S. M., Allen LaPointe, N. M., Chatterjee, R., Crowley, M. J., Dupre, M. E., Kong, D. F., Lopes, R. D., Povsic, T. J., Raju, S. S., Shah, B., et al. (2014) · Annals of Internal Medicine · doi:10.7326/m13-1467 · Cited by 178
“Of the 9 RCTs that compared PVI plus complex fractionated atrial electrographic (CFAE) ablation versus PVI alone, 1 included only patients with long-standing persistent AF (119), 2 included only patients with persistent AF (115, 160), and 4 included only patients with paroxysmal AF (112, 114, 140, 153).”
BackgroundSultan, A., Lüker, J., Andresen, D., Kuck, K. H., Hoffmann, E., Brachmann, J., Hochadel, M., Willems, S., Eckardt, L., Lewalter, T., et al. (2017) · Scientific Reports · doi:10.1038/s41598-017-16938-6 · Cited by 159
Di Biase, L., Lakkireddy, D., Trivedi, C., Deneke, T., Martinek, M., Mohanty, S., Mohanty, P., Prakash, S., Bai, R., Reddy, M., et al. (2015) · Heart Rhythm · doi:10.1016/j.hrthm.2015.02.028 · Cited by 158
Self-citation
Metadata
- Authors
- Di Biase, L., Elayi, C. S., Fahmy, T. S., Martin, D. O., Ching, C. K., Barrett, C., Bai, R., Patel, D., Khaykin, Y., Hongo, R., Hao, S., Beheiry, S., Pelargonio, G., Russo, A. D., Casella, M., Santarelli, P., Potenza, D., Fanelli, R., Massaro, R., Wang, P., Al-Ahmad, A., Arruda, M., Themistoclakis, S., Bonso, A., Rossillo, A., Raviele, A., Schweikert, R. A., Burkhardt, D. J., & Natale, A.
- Venue
- Circulation: Arrhythmia and Electrophysiology
- Published
- 2009-04
- Volume
- 2
- Issue
- 2
- Pages
- 113-119
- ISSN
- 1941-3084 (ISSN-L)
- 1941-3149
- OpenAlex
- W2129672651
- Cited by
- 157
- References
- 2
- FWCI
- 11.07
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.