Artificial Intelligence–Electrocardiography to Predict Incident Atrial Fibrillation: A Population-Based Study
Open accessThe DOI matches its Crossref record; 8 of the 8 references it cites were found in a registry or an index.
Abstract
Background: An artificial intelligence (AI) algorithm applied to electrocardiography during sinus rhythm has recently been shown to detect concurrent episodic atrial fibrillation (AF). We sought to characterize the value of AI–enabled electrocardiography (AI-ECG) as a predictor of future AF and assess its performance compared with the CHARGE-AF score (Cohorts for Aging and Research in Genomic Epidemiology–AF) in a population-based sample. Methods: We calculated the probability of AF using AI-ECG, among participants in the population-based Mayo Clinic Study of Aging who had no history of AF at the time of the baseline study visit. Cox proportional hazards models were fit to assess the independent prognostic value and interaction between AI-ECG AF model output and CHARGE-AF score. C statistics were calculated for AI-ECG AF model output, CHARGE-AF score, and combined AI-ECG and CHARGE-AF score. Results: A total of 1936 participants with median age 75.8 (interquartile range, 70.4–81.8) years and median CHARGE-AF score 14.0 (IQR, 13.2–14.7) were included in the analysis. Participants with AI-ECG AF model output of >0.5 at the baseline visit had cumulative incidence of AF 21.5% at 2 years and 52.2% at 10 years. When included in the same model, both AI-ECG AF model output (hazard ratio, 1.76 per SD after logit transformation [95% CI, 1.51–2.04]) and CHARGE-AF score (hazard ratio, 1.90 per SD [95% CI, 1.58–2.28]) independently predicted future AF without significant interaction ( P =0.54). C statistics were 0.69 (95% CI, 0.66–0.72) for AI-ECG AF model output, 0.69 (95% CI, 0.66–0.71) for CHARGE-AF, and 0.72 (95% CI, 0.69–0.75) for combined AI-ECG and CHARGE-AF score. Conclusions: In the present study, both the AI-ECG AF model output and CHARGE-AF score independently predicted incident AF. The AI-ECG may offer a means to assess risk with a single test and without requiring manual or automated clinical data abstraction.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Lip, G. Y. H., Nieuwlaat, R., Pisters, R., Lane, D. A., & Crijns, H. J. G. M. (2010) · Chest · doi:10.1378/chest.09-1584 · Cited by 6,879
Cryptogenic stroke and underlying atrial fibrillation
Sanna, T., Diener, H.-C., Passman, R. S., Di Lazzaro, V., Bernstein, R. A., Morillo, C. A., Rymer, M. M., Thijs, V., Rogers, T., Beckers, F., et al. (2014) · New England Journal of Medicine · doi:10.1056/nejmoa1313600 · Cited by 2,161
Schnabel, R. B., Yin, X., Gona, P., Larson, M. G., Beiser, A. S., McManus, D. D., Newton-Cheh, C., Lubitz, S. A., Magnani, J. W., Ellinor, P. T., et al. (2015) · The Lancet · doi:10.1016/s0140-6736(14)61774-8 · Cited by 1,746 · cited 1×
“17 As a result, the network may not be adequately trained to detect AF in lower AF prevalence populations.”
BackgroundAttia, Z. I., Noseworthy, P. A., Lopez-Jimenez, F., Asirvatham, S. J., Deshmukh, A. J., Gersh, B. J., Carter, R. E., Yao, X., Rabinstein, A. A., Erickson, B. J., et al. (2019) · The Lancet · doi:10.1016/s0140-6736(19)31721-0 · Cited by 1,613 · cited 2×
“8 Our study showed that discrimination is maximal when the AI-ECG threshold is set at 11.5%.”
BackgroundMethodInfluentialSelf-citationAtrial fibrillation in patients with cryptogenic stroke
Gladstone, D. J., Spring, M., Dorian, P., Panzov, V., Thorpe, K. E., Hall, J., Vaid, H., O'Donnell, M., Laupacis, A., Côté, R., et al. (2014) · New England Journal of Medicine · doi:10.1056/nejmoa1311376 · Cited by 1,276
Age, Gene/Environment Susceptibility-Reykjavik Study: multidisciplinary applied phenomics
Harris, T. B., Launer, L. J., Eiriksdottir, G., Kjartansson, O., Jonsson, P. V., Sigurdsson, G., Thorgeirsson, G., Aspelund, T., Garcia, M. E., Cotch, M. F., et al. (2007) · American Journal of Epidemiology · doi:10.1093/aje/kwk115 · Cited by 592 · cited 1×
“15,16 The derivation C statistic was 0.765 (95% CI, 0.748–0.781) and validation C statistics were 0.664 (95% CI, 0.632– 0.697) and 0.705 (95% CI, 0.664–0.747) for each of the studies, respectively.”
InfluentialChamberlain, A. M., Agarwal, S. K., Folsom, A. R., Soliman, E. Z., Chambless, L. E., Crow, R., Ambrose, M., & Alonso, A. (2011) · The American Journal of Cardiology · doi:10.1016/j.amjcard.2010.08.049 · Cited by 354 · cited 1×
“In the original CHARGE-AF Consortium study 6 the CHARGE-AF score was derived from 3 large US-based studies 12–14 and validated in 2 European studies.”
MethodThe Rotterdam Study: 2010 objectives and design update
Hofman, A., Breteler, M. M. B., van Duijn, C. M., Janssen, H. L. A., Krestin, G. P., Kuipers, E. J., Stricker, B. H. C., Tiemeier, H., Uitterlinden, A. G., Vingerling, J. R., et al. (2009) · European Journal of Epidemiology · doi:10.1007/s10654-009-9386-z · Cited by 244 · cited 1×
“15,16 The derivation C statistic was 0.765 (95% CI, 0.748–0.781) and validation C statistics were 0.664 (95% CI, 0.632– 0.697) and 0.705 (95% CI, 0.664–0.747) for each of the studies, respectively.”
Influential
Cited by
Armoundas, A. A., Narayan, S. M., Arnett, D. K., Spector-Bagdady, K., Bennett, D. A., Celi, L. A., Friedman, P. A., Gollob, M. H., Hall, J. L., Kwitek, A. E., et al. (2024) · Circulation · doi:10.1161/cir.0000000000001201 · Cited by 347
“43 In 36 280 patients in sinus rhythm (of whom 8.4% had known paroxysmal atrial fibrillation [AF]), Attia et al 27 reported that a single-lead ECG had an AUC for identifying silent AF of 0.87 (95% CI, 0.86–0.88).”
BackgroundInfluentialSelf-citationECG-Based Deep Learning and Clinical Risk Factors to Predict Atrial Fibrillation
Khurshid, S., Friedman, S., Reeder, C., Di Achille, P., Diamant, N., Singh, P., Harrington, L. X., Wang, X., Al-Alusi, M. A., Sarma, G., et al. (2022) · Circulation · doi:10.1161/circulationaha.121.057480 · Cited by 322
Application of artificial intelligence to the electrocardiogram
Attia, Z. I., Harmon, D. M., Behr, E. R., & Friedman, P. A. (2021) · European Heart Journal · doi:10.1093/eurheartj/ehab649 · Cited by 312
Self-citationCai, Y., Cai, Y.-Q., Tang, L.-Y., Wang, Y.-H., Gong, M., Jing, T.-C., Li, H.-J., Li-Ling, J., Hu, W., Yin, Z., et al. (2024) · BMC Medicine · doi:10.1186/s12916-024-03273-7 · Cited by 122
Chung, C. T., Lee, S., King, E., Liu, T., Armoundas, A. A., Bazoukis, G., & Tse, G. (2022) · International Journal of Arrhythmia · doi:10.1186/s42444-022-00075-x · Cited by 79
Roadmap for alleviating the manifestations of ageing in the cardiovascular system
Liberale, L., Tual-Chalot, S., Sedej, S., Ministrini, S., Georgiopoulos, G., Grunewald, M., Bäck, M., Bochaton-Piallat, M.-L., Boon, R. A., Ramos, G. C., et al. (2025) · Nature Reviews Cardiology · doi:10.1038/s41569-025-01130-5 · Cited by 59
“Monitoring age-related nonspecific electrocardiographic alterations with the help of wearable devices and artificial intelligence (AI) technology might help to identify and validate signs of cardiac ageing 178,179 .”
Vaid, A., Argulian, E., Lerakis, S., Beaulieu-Jones, B. K., Krittanawong, C., Klang, E., Lampert, J., Reddy, V. Y., Narula, J., Nadkarni, G. N., et al. (2023) · Communications Medicine · doi:10.1038/s43856-023-00240-w · Cited by 30
König, S., Hohenstein, S., Nitsche, A., Pellissier, V., Leiner, J., Stellmacher, L., Hindricks, G., & Bollmann, A. (2024) · European Heart Journal - Digital Health · doi:10.1093/ehjdh/ztad081 · Cited by 21
Tsai, C., Naser, J. A., Tsaban, G., Lee, E., Wood, J., Luis, A. S., Thaden, J. J., Kane, G. C., Pislaru, S. V., Simard, T. J., et al. (2026) · Journal of the American Heart Association · doi:10.1161/jaha.125.046558 · Cited by 5
Metadata
- Authors
- Christopoulos, G., Graff-Radford, J., Lopez, C. L., Yao, X., Attia, Z. I., Rabinstein, A. A., Petersen, R. C., Knopman, D. S., Mielke, M. M., Kremers, W., Vemuri, P., Siontis, K. C., Friedman, P. A., & Noseworthy, P. A.
- Venue
- Circulation: Arrhythmia and Electrophysiology
- Published
- 2020-12
- Volume
- 13
- Issue
- 12
- Pages
- e009355-e009355
- ISSN
- 1941-3084 (ISSN-L)
- 1941-3149
- OpenAlex
- W3098712771
- Cited by
- 126
- References
- 8
- FWCI
- 8.38
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.