CoChat

Artificial Intelligence–Electrocardiography to Predict Incident Atrial Fibrillation: A Population-Based Study

Open access
Christopoulos, Georgios, Graff-Radford, Jonathan, Lopez, Camden L., Yao, Xiaoxi, Attia, Zachi I., Rabinstein, Alejandro A., Petersen, Ronald C., Knopman, David S., Mielke, Michelle M., Kremers, Walter, Vemuri, Prashanthi, Siontis, Konstantinos C., Friedman, Paul A., Noseworthy, Peter A. · 2020 · Circulation: Arrhythmia and Electrophysiology
Cited by 126

The DOI matches its Crossref record; 8 of the 8 references it cites were found in a registry or an index.

Abstract

Background: An artificial intelligence (AI) algorithm applied to electrocardiography during sinus rhythm has recently been shown to detect concurrent episodic atrial fibrillation (AF). We sought to characterize the value of AI–enabled electrocardiography (AI-ECG) as a predictor of future AF and assess its performance compared with the CHARGE-AF score (Cohorts for Aging and Research in Genomic Epidemiology–AF) in a population-based sample. Methods: We calculated the probability of AF using AI-ECG, among participants in the population-based Mayo Clinic Study of Aging who had no history of AF at the time of the baseline study visit. Cox proportional hazards models were fit to assess the independent prognostic value and interaction between AI-ECG AF model output and CHARGE-AF score. C statistics were calculated for AI-ECG AF model output, CHARGE-AF score, and combined AI-ECG and CHARGE-AF score. Results: A total of 1936 participants with median age 75.8 (interquartile range, 70.4–81.8) years and median CHARGE-AF score 14.0 (IQR, 13.2–14.7) were included in the analysis. Participants with AI-ECG AF model output of >0.5 at the baseline visit had cumulative incidence of AF 21.5% at 2 years and 52.2% at 10 years. When included in the same model, both AI-ECG AF model output (hazard ratio, 1.76 per SD after logit transformation [95% CI, 1.51–2.04]) and CHARGE-AF score (hazard ratio, 1.90 per SD [95% CI, 1.58–2.28]) independently predicted future AF without significant interaction ( P =0.54). C statistics were 0.69 (95% CI, 0.66–0.72) for AI-ECG AF model output, 0.69 (95% CI, 0.66–0.71) for CHARGE-AF, and 0.72 (95% CI, 0.69–0.75) for combined AI-ECG and CHARGE-AF score. Conclusions: In the present study, both the AI-ECG AF model output and CHARGE-AF score independently predicted incident AF. The AI-ECG may offer a means to assess risk with a single test and without requiring manual or automated clinical data abstraction.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1161/circep.120.009355

Cites

8 of 8 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 8 references

Cited by

Metadata

Authors
Christopoulos, G., Graff-Radford, J., Lopez, C. L., Yao, X., Attia, Z. I., Rabinstein, A. A., Petersen, R. C., Knopman, D. S., Mielke, M. M., Kremers, W., Vemuri, P., Siontis, K. C., Friedman, P. A., & Noseworthy, P. A.
Venue
Circulation: Arrhythmia and Electrophysiology
Published
2020-12
Volume
13
Issue
12
Pages
e009355-e009355
ISSN
  • 1941-3084 (ISSN-L)
  • 1941-3149
OpenAlex
W3098712771
Cited by
126
References
8
FWCI
8.38
Type
journal article
Language
en
Open access
bronze

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.